Search results for "Image quality"

showing 10 items of 136 documents

Optical module for single-shot quantitative phase imaging based on the transport of intensity equation with field of view multiplexing

2021

We present a cost-effective, simple, and robust method that enables single-shot quantitative phase imaging (QPI) based on the transport of intensity equation (TIE) using an add-on optical module that can be assembled into the exit port of any regular microscope. The module integrates a beamsplitter (BS) cube (placed in a non-conventional way) for duplicating the output image onto the digital sensor (field of view – FOV – multiplexing), a Stokes lens (SL) for astigmatism compensation (introduced by the BS cube), and an optical quality glass plate over one of the FOV halves for defocusing generation (needed for single-shot TIE algorithm). Altogether, the system provides two laterally separate…

PhysicsMicroscopeImage qualitybusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONPhase (waves)Field of viewÒpticaOptometriaMultiplexingAtomic and Molecular Physics and Opticslaw.inventionLens (optics)OpticslawbusinessPhase retrievalBeam splitter
researchProduct

Single-shot slightly off-axis digital holographic microscopy with add-on module based on beamsplitter cube

2019

Slightly off-axis digital holographic microscopy (SO-DHM) has recently emerged as a novel experimental arrangement for quantitative phase imaging (QPI). It offers improved capabilities in conventional on-axis and off-axis interferometric configurations. In this contribution, we report on a single-shot SO-DHM approach based on an add-on module adapted to the exit port of a regular microscope. The module employs a beamsplitter (BS) cube interferometer and includes, in addition, a Stokes lens (SL) for astigmatism compensation. Each recorded frame contains two fields of view (FOVs) of the sample, where each FOV is a hologram which is phase shifted by π rads with respect to the other. These two …

PhysicsMicroscopeImage qualitybusiness.industryHolography02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesAtomic and Molecular Physics and Opticslaw.invention010309 opticsInterferometryOpticslaw0103 physical sciencesPhase imagingDigital holographic microscopy0210 nano-technologyPhase retrievalbusinessBeam splitterOptics Express
researchProduct

Monte Carlo evaluation of the Filtered Back Projection method for image reconstruction in proton computed tomography

2011

Abstract In this paper the use of the Filtered Back Projection (FBP) Algorithm, in order to reconstruct tomographic images using the high energy (200–250 MeV) proton beams, is investigated. The algorithm has been studied in detail with a Monte Carlo approach and image quality has been analysed and compared with the total absorbed dose. A proton Computed Tomography (pCT) apparatus, developed by our group, has been fully simulated to exploit the power of the Geant4 Monte Carlo toolkit. From the simulation of the apparatus, a set of tomographic images of a test phantom has been reconstructed using the FBP at different absorbed dose values. The images have been evaluated in terms of homogeneity…

PhysicsNuclear and High Energy Physicsmedicine.medical_specialtyTomographic reconstructionRadon transformImage qualitybusiness.industryPhysics::Medical PhysicsMonte Carlo methodIterative reconstructionImaging phantomOpticsAbsorbed doseHomogeneity (physics)medicineMedical physicsbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

DOI measurement with monolithic scintillation crystals: A primary performance evaluation

2007

We report a first assessment of image quality enhancement achieved by the implementation of depth of interaction detection with monolithic crystals. The method of interaction depth measurement is based on analogue computation of the standard deviation with an enhanced charge divider readout. This technique of depth of interaction detection was developed in order to provide fast and determination of this parameter at a reasonable increase of detector cost. The detector consists of an large-sized monolithic scintillator coupled to a position sensitive photomultiplier tube. A special design feature is the flat-topped pyramidal shape of the crystal. This reduces image compression near the edges…

PhysicsPhotomultiplierOpticsPhysics::Instrumentation and DetectorsImage qualityPoint sourcebusiness.industryMeasured depthDetectorScintillatorbusinessImage resolutionImaging phantom2007 IEEE Nuclear Science Symposium Conference Record
researchProduct

A mammographic phantom image reconstruction through Monte Carlo techniques

2005

Mammographic phantoms are employed during quality control test in breast screening locations and other health centres. These quality controls are performed to achieve the image quality required to detect breast abnormalities, ensuring the minimum risk to radiographied women. The aim of this study is the development of a methodology to reproduce the image of a mammogram during a routine exposure in a breast screening programme. In a first step, the CIRS 11A (MAMMO PHANTOM SP01) mammographic phantom has been simplified and modelled with the Monte Carlo transport code MCNP-4c2. Different tallies (F2 and F5) have been used to score the photon flux under the phantom, and a group of aluminium lay…

Physicsmedicine.medical_specialtyPixelmedicine.diagnostic_testbusiness.industryImage qualityMonte Carlo methodIterative reconstructionImaging phantomKermamedicineDosimetryMammographyComputer visionMedical physicsArtificial intelligencebusiness
researchProduct

Wider is better but sharper is not: optimizing the image of camera-monitor systems

2021

The replacement of rear-view mirrors with camera-monitor systems introduces new opportunities for design, such as altering the image quality and the rearward field-of-view. We investigated how the image quality and field-of-view might affect the distance and time-to-contact estimation of other vehicles. Eighty-six subjects estimated either their egocentric distance to a stationary vehicle (Experiment I) or the time-to-contact to an approaching vehicle (Experiment II). Throughout the experiments, the pixel density and either the field-of-view or the viewing condition varied. A larger field-of-view increased distance estimation accuracy and confidence. Reduced pixel density led to larger esti…

PixelImage qualityComputer sciencebusiness.industrymedia_common.quotation_subjectPhysical Therapy Sports Therapy and RehabilitationHuman Factors and ErgonomicsField of viewDirtImage (mathematics)Contrast (vision)Computer visionArtificial intelligencebusinessImage resolutionPixel densitymedia_common
researchProduct

Automatic analysis of speckle photography fringes

1997

Speckle interferometry is a technique adequate to metrological problems such as the measurement of object deformation. An automatic system of analysis of such measurements is given; it consists of a motorized x-y plate positioner controlled by computer, a CCD video camera, and software for image analysis. A fringe-recognition algorithm determines the spacing and orientation of the fringes and permits the calculation of the magnitude and direction of the displacement of the analyzed object point in images with variable degrees of illumination. For a 256 x 256 pixel image resolution, the procedure allows one to analyze from three fringes to a number of fringes that corresponds to 3 pixels/fri…

PixelImage qualitybusiness.industryComputer scienceOrientation (computer vision)Materials Science (miscellaneous)Astrophysics::Instrumentation and Methods for AstrophysicsVideo cameraSpeckle noiseImage processingHolographic interferometryIndustrial and Manufacturing Engineeringlaw.inventionOpticslawComputer Science::Computer Vision and Pattern RecognitionSpeckle imagingBusiness and International ManagementbusinessImage resolutionApplied Optics
researchProduct

Objective improvement of the visual quality of ion microscope images

2013

The need to operate with low ion beam fluences implies the images obtained using ion microscope (IM) are often grainy and have poor visual quality compared to what can be obtained using e.g. confocal microscopy. This results from the Poissonian distribution of counts in pixels. Here we report work on some different approaches for objectively improving the visual quality of IM images. In this work we present (i) dramatic improvement in the visual image quality of off-axis and direct-scanning transmission ion microscopy (STIM) images by suppression of zero-pixels; (ii) denoising of PIXE images using wavelet filtering and (iii) use of the feature preserving characteristics of wavelet filtering…

PixelIon beamta114Image qualityChemistrybusiness.industryNoise reductionCondensed Matter PhysicsThresholdingAtomic and Molecular Physics and OpticsSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsWaveletOpticsFeature (computer vision)Computer visionArtificial intelligenceElectrical and Electronic EngineeringbusinessField ion microscopeMicroelectronic Engineering
researchProduct

A spectral hazy image database

2020

We introduce a new database to promote visibility enhancement techniques intended for spectral image dehazing. SHIA (Spectral Hazy Image database for Assessment) is composed of two real indoor scenes M1 and M2 of 10 levels of fog each and their corresponding fog-free (ground-truth) images, taken in the visible and the near infrared ranges every 10 nm starting from 450 to 1000 nm. The number of images that form SHIA is 1540 with a size of \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$1312\,\times \,1082$$\end{d…

Pixelbusiness.industryImage qualityAccurate estimationComputer scienceImage (category theory)Near-infrared spectroscopyVisibility (geometry)020207 software engineering02 engineering and technologyArticle[INFO.INFO-TI] Computer Science [cs]/Image Processing [eess.IV]Image databaseHazy image databaseDehazing[INFO.INFO-TI]Computer Science [cs]/Image Processing [eess.IV]0202 electrical engineering electronic engineering information engineeringImage quality020201 artificial intelligence & image processingComputer visionNoise (video)Artificial intelligencebusiness
researchProduct

Digitale Mehrschichttomographie

1989

A set of projection images is acquired during longitudinal tomography with an image intensifier TV system. Reconstruction of tomograms in each desired plane is achieved by shifting and summing up of the digitalized projection images. Digital multilayer and conventional film tomograms mainly of the respiratory tract and skeleton have been compared in 100 patients. Image quality is comparable with both methods. Disadvantage of digital tomography is lower spatial resolution (512 x 512 matrix size); advantages include lower radiation dose, shorter study time, and facilities of digital imaging.

Plane (geometry)business.industryComputer scienceImage qualityDigital imagingImage intensifierlaw.inventionlawRadiology Nuclear Medicine and imagingComputer visionTomographyArtificial intelligenceProjection (set theory)Nuclear medicinebusinessImage resolutionDigital radiographyRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct