Search results for "Image"
showing 10 items of 6818 documents
Plantar fascia evaluation with a dedicated magnetic resonance scanner in weight-bearing position: our experience in patients with plantar fasciitis a…
2010
Purpose. This study assessed the usefulness of upright weight-bearing examination of the ankle/hind foot performed with a dedicated magnetic resonance (MR)imaging scanner in the evaluation of the plantar fascia in healthy volunteers and in patients with clinical evidence of plantar fasciitis. Materials and methods. Between January and March 2009, 20 patients with clinical evidence of plantar fasciitis (group A) and a similar number of healthy volunteers (group B) underwent MR imaging of the ankle/hind foot in the upright weight-bearing and conventional supine position. A 0.25-Tesla MR scanner (G-Scan, Esaote SpA, Genoa, Italy) was used with a dedicated receiving coil for the ankle/hind foot…
Thinking about movement hurts: The effect of motor imagery on pain and swelling in people with chronic arm pain
2008
Objective: Chronic painful disease is associated with pain on movement, which is presumed to be caused by noxious stimulation. We investigated whether motor imagery, in the absence of movement, increases symptoms in patients with chronic arm pain. Methods: Thirty‐seven subjects performed a motor imagery task. Pain and swelling were measured before, after, and 60 minutes after the task. Electromyography findings verified no muscle activity. Patients with complex regional pain syndrome (CRPS) were compared with those with non‐CRPS pain. Secondary variables from clinical, psychophysical, and cognitive domains were related to change in symptoms using linear regression. Results: Motor imagery in…
Rapid Musculoskeletal Magnetic Resonance Imaging Using Integrated Parallel Acquisition Techniques (IPAT) - Initial Experiences
2003
Purpose To investigate the feasibility of using multiple receiver coil elements for time saving integrated parallel imaging techniques (iPAT) in traumatic musculoskeletal disorders. Material and methods 6 patients with traumatic derangements of the knee, ankle and hip underwent MR imaging at 1.5 T. For signal detection of the knee and ankle, we used a 6-channel body array coil that was placed around the joints, for hip imaging two 4-channel body array coils and two elements of the spine array coil were combined for signal detection. All patients were investigated with a standard imaging protocol that mainly consisted of different turbo spin-echo sequences (PD-, T (2)-weighted TSE with and w…
Centrifugal (inside-out) enhancement of liver hemangiomas: a possible atypical appearance on contrast-enhanced US.
2007
Abstract Objective To report the prevalence and to describe the atypical centrifugal (inside-out) appearance of contrast-enhancement of liver hemangiomas on contrast-enhanced sonography. Materials and methods Baseline and SonoVue ® -enhanced ultrasonography of 92 patients with 158 liver hemangiomas – considered atypical at grey-scale examination and confirmed by computed tomography, magnetic resonance imaging and ultrasound follow-up – were reviewed in consensus by two experienced radiologists, who evaluated baseline echogenicity and the dynamic enhancement pattern of each lesion looking for the presence of central enhancing foci in the arterial phase followed by a centrifugal (inside-out) …
Fatty replacement of bone marrow after radiation therapy for Hodgkin disease: Quantification with chemical shift imaging
1993
The authors studied the long-term fatty replacement of bone marrow in 23 patients who had received radiation therapy for Hodgkin disease, with T1-weighted magnetic resonance imaging and quantitative chemical shift imaging. T1-weighted images revealed a mostly homogeneous high-signal-intensity pattern, in contrast to the hypointense pattern of nonirradiated marrow. The degree of fatty replacement was objectively assessed with chemical shift imaging, comparing patients to age-matched healthy volunteers. The authors found an increase in relative fat signal of 37% in the thoracic spine and 34% in the lumbar spine. The relative fat signal of nonirradiated pelvic and femoral marrow was decreased …
Microcirculation in the healing of surgical wounds in the oral cavity.
2013
Abstract. The aim of this research is to evaluate in vivo the characteristics of microcirculation after taking a biopsy sample from the oral mucosa. 20 patients were recruited to the study and all underwent an oral mucosa biopsy for the excision of benign neoformations. The modifications in the oral microcirculation were evaluated in vivo in correspondence to the surgical site through videocapillaroscopy at three different times: 30 min before the biopsy; 48 h after the biopsy; and 7 days after the biopsy. The statistical significance was checked with the Mann–Whitney U-test (P < 0.05). The analysis of videocapillaroscopic patterns showed statistically significant variations relative to the…
[Double second branchial cleft anomaly].
2009
Second branchial cleft anomalies are the most common of this type of neck masses. They can be classified in four types (Bailey/Proctor classification) according to their location. Type II is the most common, and related to vital neck structures such as the carotid artery and jugular vein. Cysts are the most frequent among them. Management consists of surgical excision of the cyst and tract by cervicotomy to avoid recurrence. We present an extremely rare case of a 32-year-old male who presented a sudden appearance of a right lateral neck mass that was identified by an image study as a double branchial cleft cyst. A review of simultaneous branchial cleft cyst in the literature is also made.
Imaging the visual autokinetic illusion with fMRI
2005
During fixation of a stationary, dim light-emitting diode (LED) in complete darkness, a subtle, apparent motion is perceived which is called autokinesis. This autokinetic illusion increases with increasing fixation time. Eleven healthy subjects were examined by fMRI while fixating an LED in darkness for 35 s. BOLD signal changes of the first and the second half of the fixation period were compared. While the stimulus was the same for both periods, perception differed in that autokinesis was more pronounced in the second half. This second half of the period was associated with bilateral activations in the motion-sensitive middle occipito-temporal area known as MT/V5. Our finding suggests tha…
Oculovestibular interactions under microgravity.
1993
On a space mission in March 1992 a set of experiments were performed aimed at clarifying the interaction between visual, proprioceptive and vestibular inputs to the equilibrium system. Using the VESTA goggle facility from the European Space Agency we investigated the effect of pure neck receptor stimulation on eye position as measured by the flash afterimage method and on perception of a head-fixed luminous line in space. Space vestibular adaptation processes were measured by rotating pattern perception during prescribed head movements. It was found that static ocular counterrotation does not occur under micro gravity conditions. This result suggests that the neck receptors apparently do no…
Standardized T2* map of normal human heart in vivo to correct T2* segmental artefacts.
2007
A segmental, multislice, multi-echo T2* MRI approach could be useful in heart iron-overloaded patients to account for heterogeneous iron distribution, demonstrated by histological studies. However, segmental T2* assessment in heart can be affected by the presence of geometrical and susceptibility artefacts, which can act on different segments in different ways. The aim of this study was to assess T2* value distribution in the left ventricle and to develop a correction procedure to compensate for artefactual variations in segmental analysis. MRI was performed in four groups of 22 subjects each: healthy subjects (I), controls (II) (thalassemia intermedia patients without iron overload), thala…