Search results for "Imaging"

showing 10 items of 6802 documents

Tu1451 Medjet - A New CO2 Based Disposable Cleaning Device Allows Safe and Effective Colon Cleansing During Colonoscopy: A Prospective Open Labeled C…

2011

medicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentGastroenterologyColon cleansingColonoscopylaw.inventionSurgeryRandomized controlled triallawmedicineRadiology Nuclear Medicine and imagingbusinessGastrointestinal Endoscopy
researchProduct

Regionäre Lymphknotenmetastasen maligner Kopf-Hals-Tumoren:

1991

Sonography and computed tomography are used in staging of lymph nodes of patients with head and neck cancer. The accuracy of sonography (90%) and computed tomography (85%) is comparable or better than the palpatory accuracy (85%). The better delineation of reactive swollen cervical nodes leads to a higher sensitivity of sonography (90%) and computed tomography (84%) versus palpation (74%), but a lower specifity (palpation 94%, sonography 90%, computed tomography 86%). A literature survey shows that sonography, computed tomography and magnetic resonance imaging of cervical lymph nodes are comparable good methods.

medicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentHead and neck cancerMagnetic resonance imagingNeck dissectionmedicine.diseasePalpationmedicine.anatomical_structureOtorhinolaryngologyCervical lymph nodesmedicineTomographyRadiologyLiterature surveybusinessLymph nodeLaryngo-Rhino-Otologie
researchProduct

Cardiovascular Magnetic Resonance Demonstrates Reversible Atrial Dysfunction After Catheter Ablation of Persistent Atrial Fibrillation

2013

Reversible Dysfunction After Persistent AF Ablation Introduction There is a paucity of data on atrial injury following ablation of persistent atrial fibrillation (AF). This study aimed at assessing reversibility of atrial dysfunction after successful persistent AF ablation using cardiovascular magnetic resonance (CMR). Methods and Results CMR was performed during sinus rhythm (SR) in 20 consecutive patients with persistent AF at baseline (BL) within 24 hours after ablation and after 6-month follow-up (FU). Catheter ablation included atrial substrate modification using the stepwise approach following pulmonary vein isolation (PVI) in order to attempt termination of persistent AF. Active left…

medicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentMagnetic resonance imagingCatheter ablationAtrial fibrillationAblationmedicine.diseasePulmonary veinPhysiology (medical)Internal medicineEdemaPersistent atrial fibrillationcardiovascular systemCardiologyMedicineSinus rhythmcardiovascular diseasesmedicine.symptomCardiology and Cardiovascular MedicinebusinessJournal of Cardiovascular Electrophysiology
researchProduct

Discordancia clínico-radiológica y resolución espontánea de un hematoma postcateterización epidural

2008

Neuraxial techniques are considered safe if certain guidelines are followed, but they are not risk free. We report the case of an 81-year-old woman with an invasive bladder tumor who underwent radical cystectomy with a Bricker-type procedure. General anesthesia was used and epidural analgesia was also provided for surgical and postoperative pain management. Late in the postoperative recovery period a large epidural hematoma was diagnosed based on radiologic signs of spinal cord compression, in the absence of symptoms other than mild and progressive back pain that developed after extubation. The surgeon decided against emergency surgery to reduce compression. Symptoms resolved gradually, and…

medicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentMagnetic resonance imagingCritical Care and Intensive Care Medicinemedicine.diseaseSurgeryCystectomyAnesthesiology and Pain MedicineEpidural hematomaHematomaSpinal cord compressionHemostasisAnesthesiamedicineBack painBladder tumormedicine.symptombusinessRevista Española de Anestesiología y Reanimación
researchProduct

Video-Assisted Navigation for Adjustment of Image-Guidance Accuracy to Slight Brain Shift

2015

Background Information supplied by an image-guidance system can be superimposed on the operating microscope oculars or on a screen, generating augmented reality. Recently, the outline of a patient's head and skull, injected in the oculars of a standard operating microscope, has been used to check the registration accuracy of image guidance. Objective To propose the use of the brain surface relief and superficial vessels for real-time intraoperative visualization and image-guidance accuracy and for intraoperative adjustment for brain shift. Methods A commercially available image-guidance system and a standard operating microscope were used. Segmentation of the brain surface and cortical bloo…

medicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentMagnetic resonance imagingImaging phantomSurgeryVisualizationDigital imagemedicineSurgerySegmentationComputer visionAugmented realityNeurology (clinical)Artificial intelligencebusinessOperating microscopeCraniotomyOperative Neurosurgery
researchProduct

Can Early Postoperative O-(2-18FFluoroethyl)-l-Tyrosine Positron Emission Tomography After Resection of Glioblastoma Predict the Location of Later Tu…

2019

Objective Glioblastoma inevitably recurs despite aggressive therapy. Therefore, it would be helpful to predict the location of tumor recurrence from postoperative imaging to customize further treatment. O-(2-18Ffluoroethyl)- l -tyrosine (FET) positron emission tomography (PET) might be a helpful technique, because tumor tissue can be differentiated from normal brain tissue with high specificity. Methods Thirty-two consecutive patients with perioperative and follow-up imaging data available were included. On postoperative FET-PET, the tumor/normal brain (TTB) ratio around the resection cavity borders was measured. Increased TTB ratios were recorded and anatomically correlated with the site o…

medicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentMagnetic resonance imagingPerioperativemedicine.diseaseImaging dataResectionTumor recurrenceRadiation therapy03 medical and health sciences0302 clinical medicinePositron emission tomography030220 oncology & carcinogenesisMedicineSurgeryNeurology (clinical)Radiologybusiness030217 neurology & neurosurgeryGlioblastomaWorld Neurosurgery
researchProduct

Rektumkarzinom: Behandeln wir zu häufig neoadjuvant? Vorschläge zu einer selektiveren, MRT-basierten Indikation

2006

The present-day optimised surgery (concept of total mesorectal excision) with quality assurance by standardized pathologic examination, advances in radiotherapy and the possibilities of high-spatial-resolution MR imaging require reconsideration of pros and contras of neoadjuvant therapy and respective data. According to the resulting new proposal neoadjuvant long-course radiochemotherapy is indicated for patients with 1) fixed questionably R0 resectable tumors, 2) mobile tumors with the MRT finding of tumor involving the mesorectal fascia or 1 mm or less from it, 3) low rectal tumors extending below the levator origin and invading beyond the muscularis propria. If a high risk of local recur…

medicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentMagnetic resonance imagingTotal mesorectal excisionSurgeryRadiation therapyRectal carcinomamedicineCombined Modality TherapySurgeryCircumferential resection marginbusinessNeoadjuvant therapyMesorectalZentralblatt für Chirurgie
researchProduct

Functional MRI and motor behavioral changes obtained with constraint-induced movement therapy in chronic stroke

2011

Background:  The clinical benefits of intensive stroke rehabilitation vary individually. We used multimodal functional imaging to assess the relationship of clinical gain and imaging changes in patients with chronic stroke whose voluntary motor control improved after constraint-induced movement therapy (CIMT). Methods:  Eleven patients (37.6 ± 36.8 months from stroke) were studied by functional MRI (fMRI), transcranial magnetic stimulation (TMS), and behavioral assessment of hand motor control (Wolf Motor Function Test) before and after 2 weeks of CIMT. Individual and group-level changes in imaging and behavioral parameters were investigated. Results:  Increase in fMRI activation in the sen…

medicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentMotor controlMagnetic resonance imagingmedicine.diseasebehavioral disciplines and activitiesBrain mappingConstraint-induced movement therapyFunctional imagingTranscranial magnetic stimulationPhysical medicine and rehabilitationNeurologyLateralitymedicineNeurology (clinical)businessStrokepsychological phenomena and processesEuropean Journal of Neurology
researchProduct

Morphologische und funktionelle Evaluation pulmonaler Gefäßanomalien mittels schneller MR-Techniken

2002

Purpose: To evaluate breath-hold MR techniques for morphologic and functional assessment of vascular abnormalities of the pulmonary vasculature. Patients and Methods: 13 patients aged 11 to 60 years with different vascular abnormalities of the pulmonary vasculature (5 patients with 16 arteriovenous malformations, 8 patients with partial anomalous pulmonary venous return) underwent MR imaging at 1.5 T. For morphological assessment, a contrast-enhanced 3D MR angiography (ce-MRA) was performed after a timing run. Segmented cine- and velocity-encoded GRE sequences were used for delineation of associated cardiac septal defects and for determination of systemic left-to-right or intrapulmonary shu…

medicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentPartial anomalous pulmonary venous returnArteriovenous malformationmedicine.diseaseMagnetic resonance angiographyScimitar syndromemedicine.arteryPulmonary arteryAscending aortaMedicineAnomalous pulmonary venous returnRadiology Nuclear Medicine and imagingRadiologybusinessCardiac catheterizationRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

The Sum of ST-Segment Elevation Is the Best Predictor of Microvascular Obstruction in Patients Treated Successfully by Primary Percutaneous Coronary …

2010

Introduction and objectives The usefulness of ST-segment elevation resolution (STR) for predicting epicardial reperfusion is well established. However, it is still not clear how ST-segment changes are related to microvascular obstruction (MVO) observed by cardiovascular magnetic resonance (CMR) after primary percutaneous coronary intervention (pPCI) for ST-segment elevation myocardial infarction (STEMI). Methods The study involved 85 consecutive patients admitted for a first STEMI and treated by pPCI who had a patent infarct-related artery. An ECG was recorded on admission and 90 min and 6, 24, 48 and 96 h after pPCI. Thereafter, STR and the sum of ST-segment elevation (sumSTE) in all leads…

medicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentPercutaneous coronary interventionMagnetic resonance imagingGeneral MedicineOdds ratiomedicine.diseaseRevascularizationConfidence intervalmedicine.anatomical_structureInternal medicinemedicineCardiologyST segmentcardiovascular diseasesMyocardial infarctionbusinesshuman activitiesArteryRevista Española de Cardiología (English Edition)
researchProduct