Search results for "Implant stability"

showing 10 items of 20 documents

Repeatability of the resonance frequency analysis values in implants with a new technology

2019

Background Assess the reliability (by means of reproducibility and repeatability) of the PenguinRFA system, analyse the ISQ values of different implant types and correlate the ISQ with the insertion torque during the placement of the implant. Material and Methods 120 rough surface implants were placed in bovine bone (type II and III). The implants were divided into groups, according to its design. Once the implants were in place, the exact insertion torque was registered. Then, primary stability was measured by means of the resonance frequency analysis with the PenguinRFA and the Osstell ISQ devices. In each implant two transducers of each device were used. Three measurements were obtained …

Materials scienceIntraclass correlationVibrationDental Prosthesis Retention03 medical and health sciences0302 clinical medicineAnimalsGeneral DentistryDental ImplantsReproducibilityResearchDental Implantation EndosseousResonance Frequency AnalysisReproducibility of Results030206 dentistryRepeatability:CIENCIAS MÉDICAS [UNESCO]Implant stability quotientResonance frequency analysisDental Prosthesis DesignTorqueOtorhinolaryngologyRough surfaceUNESCO::CIENCIAS MÉDICASImplant typesCattleSurgeryImplantOral SurgeryBiomedical engineeringMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Relation between bone quality values from ultrasound transmission velocity and implant stability parameters--an ex vivo study.

2011

Aim The objective of this study was to determine the relationship between bone qualities measured by ultrasound transmission velocity (UTV) and primary implant stability parameters measured by radiofrequency analysis (RFA) and push-out test (POT) in an ex-vivo model. Materials and methods Three blocks of fresh porcine bone samples were obtained from different anatomic regions, correlating to cortical, mixed and cancellous bone. Mechanical bone qualities of these samples were measured using UTV (expressed in m/s) prior to implantation. Three similar implants (4.1 × 11 mm, AstraTech OS) were inserted into each of the procured bone blocks. The evaluation of implant-bone interface stability was…

Materials scienceRadio WavesSwineDentistryIn Vitro TechniquesDental Prosthesis RetentionIliumImplants ExperimentalPorcine boneBone qualitymedicineAnimalsUltrasonographyDental ImplantsTibiabusiness.industryUltrasoundDental Implantation EndosseousImplant stability quotientmedicine.anatomical_structureModels AnimalImplantOral SurgerybusinessCancellous boneEx vivoBiomedical engineeringClinical oral implants research
researchProduct

The effects of surgical preparation techniques and implant macro-geometry on primary stability : an in vitro study

2016

Background The attainment of a good primary stability is a necessary condition to ensure the success of osseointegration in implantology. In type IV cancellous bone, however, it is possible that a reduced primary stability can lead to an increased rate of failure. The aim of this study was therefore to determine, with the help of the resonance frequency (Osstell mentor), which technique of implant site preparation (piezo surgery, conventional, under-preparation, bone compaction, osteodistraction) and macro-geometry is able to improve implant stability in type IV cancellous bone. Material and Methods 10 pig ribs were prepared with a surgical pre-drilled guide, calibrated for a correct implan…

Materials scienceSwineResonance frequency analysisDentistryIn Vitro TechniquesOsseointegration03 medical and health sciences0302 clinical medicineimplant primary stability; implant site preparation; resonance frequency analysis; surgery; otorhinolaryngology2734 pathology and forensic medicine; dentistry (all)OsseointegrationPreoperative CaremedicineAnimalsIn vitro studySurgical preparationImplant primary stability030223 otorhinolaryngologyGeneral DentistryImplant site preparationRib cagebusiness.industryResearch030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Implant stability quotientImplant primary stability; Implant site preparation; Resonance frequency analysis; Animals; Dental Implantation; In Vitro Techniques; Preoperative Care; Swine; OsseointegrationDental Implantationmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryImplantOral SurgerybusinessCancellous bone
researchProduct

Post extractive implant: evaluation of the critical aspects

2017

Purpose Nowadays, implant supported prosthetic rehabilitation is a reliable procedure to replace compromised or untreatable teeth. The purpose of this review is to explore the concept of post extractive implant and the indications for clinical practice through an analysis of recent studies in the literature. All the main factors that could influence the outcome of this treatment will also be considered. Materials and methods Focusing on the extraction-socket healing time, three different implant insertion protocols have been defined: Immediate implant placement (IIP), Early implant placement (EIP), Delayed implant placement (DIP). The entity of bone remodeling can be associated with differe…

Post extractive implantsRehabilitationBone remodeling; Implant stability; Post extractive implants; Dentistry (all)Prosthetic rehabilitationbusiness.industrymedicine.medical_treatmentPlatform switchingDentistrySoft tissue030206 dentistryReviewImplant stabilityBone remodelingOral hygieneOsseointegration03 medical and health sciences0302 clinical medicinePost extractive implantBone qualitymedicineDentistry (all)ImplantbusinessGeneral Dentistry030215 immunology
researchProduct

Secondary implant stability outcome of immediate versus late placed variable-thread implants in the maxilla. A retrospective cohort study

2017

BACKGROUND The healing of xenograft augmentated intra-alveolar gaps following immediate implant placement (IMIP) after tooth extraction is likely to differ in time and density compared to the native bone part that directly contacts the implant. MATERIAL AND METHODS Secondary implant stability (SIS) data recorded 2-3 months following a late implant placement protocol (LIP) (n= 43) and 6-8 months following an immediate implant placement protocol (IMIP) (n=33) of variable-thread implants (Nobel Active™) in the maxilla were retrospectively collected from files of 63 patients (42 females, 21 males). Statistical analysis was performed using a generalized estimating equation model (GEE). Data spli…

Resonance frequency analysisDentistryHard tissue03 medical and health sciences0302 clinical medicineAnkylosMedicineStatistical analysisPeriodontology030212 general & internal medicineGeneral DentistryCellPlusbusiness.industryDentistry(all)ResearchRetrospective cohort study030206 dentistrySecondary implant stabilityImmediate implant:CIENCIAS MÉDICAS [UNESCO]periotestStraumannImplant placementResonance frequency analysisMaxillaUNESCO::CIENCIAS MÉDICASImplantSLAbusinessOsstell Mentor
researchProduct

Sensitivity and Specificity of Stability Criteria for Immediately Loaded Splinted Maxillary Implants

2014

Background To assess the suitability of dental implants for immediate loading, primary stability is usually evaluated intraoperatively. Purpose This retrospective study aimed to assess the suitability of three stability parameters – namely, insertion torque (IT), implant stability quotient (ISQ; measured by resonance frequency analysis), and Periotest (PT) values – as potential predictors for the risk of nonosseointegration of immediately loaded splinted implants. The stability parameters were routinely collected under immediate loading. Materials and Methods Nineteen patients with 11 edentulous and 8 partially edentulous maxillae were treated with 105 dental implants, which were immediatel…

business.industrymedicine.medical_treatmentArea under the curveDentistryAnatomyImplant stability quotientOsseointegrationResonance frequency analysisMaxillaImmediate loadingmedicineImplantOral SurgeryDenturesbusinessGeneral DentistryClinical Implant Dentistry and Related Research
researchProduct

Stability and marginal bone loss in implants placed using piezoelectric osteotomy versus conventional drilling: systematic review and meta-analysis.

2021

Background The main objective of this systematic review was to compare primary and secondary implant stability between placement with piezoelectric osteotomy and conventional drilling, comparing marginal bone losses as a secondary objective. Material and Methods An electronic search was conducted using PubMed (MEDLINE), Scopus, and Cochrane Library (Wiley) databases, besides a manual search. Results A total of 153 articles were retrieved, 39 from Pubmed, 44 from Scopus, and 70 from the Cochrane Library. After removing duplicates, 112 articles (1 from the manual search) were screened, and 9 were finally selected for qualitative and statistical analyses. Conclusions Piezoelectric surgery is a…

caveolin-1medicine.medical_treatmentameloblastic carcinomareal-time polymerase chain reactioneducationMEDLINEDentistryReviewImplant stabilityCochrane LibraryOsteotomyOsseointegrationameloblastomaOsseointegrationMedicineHumansPiezosurgeryDental implantGeneral DentistryImplant site preparationUNESCO:CIENCIAS MÉDICASPiezoelectric surgeryDental Implantsbusiness.industryMarginal bone lossDental implantsDental Implantation EndosseousImplant stability quotientOsteotomyOtorhinolaryngologyPiezoelectric surgeryimmunohistochemistrySurgeryImplantbusinessImplantologyConventional drillMedicina oral, patologia oral y cirugia bucal
researchProduct

Anterolateral thigh perforator flap made by customized 3D-printing fabrication of fixed positioning guide for oromaxillofacial reconstruction:a preli…

2022

Oromaxillofacial carcinomas frequently result in serious tissue defect due to enlarged resection for treating their extensive invasion, which require challenging reconstruction. Three-dimensional (3D) printing is an advanced technology which has greatly promoted the progress of craniomaxillofacial reconstructive surgery. This present study aimed to investigate the advantages of anterolateral thigh (ALT) perforator flap manufactured by 3D printing fixed positioning guide template in curing oromaxillofacial defect. Twenty patients with oromaxillofacial defects resulted from severe primary malignant tumors were divided into experimental group assisted by digital technique (n=8) and controlled …

implant stabilitythread designosseointegrationPlastic Surgery ProceduresEsthetics DentalPostoperative ComplicationsThighOtorhinolaryngologymicrogeometrydental implantsPrinting Three-DimensionalHumansSurgeryPerforator FlapGeneral DentistryUNESCO:CIENCIAS MÉDICAS
researchProduct

Efficacy of the laser at low intensity on primary burning oral syndrome: a systematic review.

2020

Background Primary burning mouth syndrome (BMS) is a chronic clinical condition of idiopathic mainly characterized by pain and a burning sensation in the oral cavity. The application of laser at low intensity therapy is a treatment option. This systematic review evaluated the efficacy of laser therapy in treating symptoms of burning mouth syndrome. Material and Methods The study was formulated according to the PRISMA and Cochrane guidelines. Seven databases were used as primary sources of research. Only randomized controlled clinical trials were included. The efficacy of the therapy was estimated comparing the values of the visual and numerical scales of pain before and after laser treatmen…

marginal bone lossmedicine.medical_specialtypiezosurgeryPainBurning Mouth SyndromeReviewlaw.inventionTongue DiseasesRandomized controlled triallawTongueStatistical significancemedicineHumansconventional drillOral mucosaLow-Level Light TherapyGeneral DentistryUNESCO:CIENCIAS MÉDICASBurning Sensationimplant stabilitydental implantOral Medicine and Pathologybusiness.industryLasersConfoundingBurning mouth syndromeMiddle AgedClinical trialimplant site preparationmedicine.anatomical_structureOtorhinolaryngologypiezoelectric surgeryPhysical therapySurgeryFemalemedicine.symptombusinessMedicina oral, patologia oral y cirugia bucal
researchProduct

Influence of the Screw Positioning on the Stability of Locking Plate for Proximal Tibial Fractures: A Numerical Approach

2020

Tibial fractures are common injuries in people. The proper treatment of these fractures is important in order to recover complete mobility. The aim of this work was to investigate if screw positioning in plates for proximal tibial fractures can affect the stability of the system, and if it can consequently influence the patient healing time. In fact, a more stable construct could allow the reduction of the non-weight-bearing period and consequently speed up the healing process. For that purpose, virtual models of fractured bone/plate assemblies were created, and numerical simulations were performed to evaluate the reaction forces and the maximum value of the contact pressure at the screw/bo…

musculoskeletal diseasesMaterials sciencemedicine.medical_treatmentHealing timelcsh:TechnologyStability (probability)Locking platelcsh:Chemistry03 medical and health sciences0302 clinical medicinemedicineCADGeneral Materials Science030212 general & internal medicineTibial fractureSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria Industrialelcsh:QH301-705.5InstrumentationReduction (orthopedic surgery)implant stabilityFluid Flow and Transfer ProcessesOrthodonticsFEM030222 orthopedicslcsh:TProcess Chemistry and TechnologyWork (physics)General Engineeringtibial fracturemusculoskeletal systemlocking plateslcsh:QC1-999Finite element methodComputer Science Applicationsreverse engineeringlcsh:Biology (General)lcsh:QD1-999lcsh:TA1-2040Proper treatmentlcsh:Engineering (General). Civil engineering (General)lcsh:PhysicsLocking plateApplied Sciences
researchProduct