Search results for "Incisional hernia"

showing 9 items of 39 documents

Effect of Fibrin Sealant on Seroma Formation Post-Incisional Hernia Repair

2020

Background: Development of seroma after incisional hernia repair is a common complication. Our study aims to compare the outcomes of sublay incisional hernia repairs with or without spray instillation of fibrin glue. Methods: We enrolled fifty patients undergoing incisional hernia repair. In all patients a suction drain was placed in the subcutaneous space. In one group (FG) 4 ml fibrin glue was instilled in the subcutaneous space. In the control group (C) patients did not receive any prevention measure. Wounds fluids were collected on post-operative day 1 (POD) and once daily until drain removal. All patients were followed up by ultrasound on POD 15, 20, 40, 60. Results: Drain fluid produc…

incisional herniamedicine.medical_specialtyIncisional herniaAdministration TopicalFibrin Tissue AdhesiveSuctionFibrinmedicineHumansFibrin glueHerniorrhaphySurgical repairbiologybusiness.industrySealantUltrasoundfibrin sealantLength of Staymedicine.diseaseHernia VentralSurgeryTreatment Outcomefibrin sealant incisional hernia seroma surgical hernia repairsurgical hernia repairsurgical procedures operativeseromaSeromabiology.proteinTissue AdhesivesSurgeryComplicationbusinessChirurgia
researchProduct

Acute inflammatory response after inguinal and incisional hernia repair with implantation of polypropylene mesh of different size.

2005

The purpose of this study was to assess the modifications of interleukin (IL)-6, C-reactive protein (CRP), leukocytes and fibrinogen after implantation of polypropylene mesh.Thirty-six patients were included in this study and divided into two groups. To the first group were allocated patients affected by inguinal hernia and undergoing conventional repair (subgroup Ia) or hernioplasty with 40-cm(2) polypropylene mesh (subgroup Ib). To the second group were allocated patients affected by incisional hernia and undergoing conventional repair (subgroup IIa) or incisional hernia repair with 400-cm(2) polypropylene mesh (subgroup IIb). Peripheral venous blood samples were collected 24 h before sur…

medicine.medical_specialtyIncisional herniaBiocompatible MaterialsHernia InguinalFibrinogenPolypropylenesProsthesis ImplantationmedicineLeukocytesHumansHerniaHerniorrhaphyInflammationbiologybusiness.industryInterleukin-6C-reactive proteinFibrinogenVenous bloodMiddle AgedSurgical Meshmedicine.diseaseSurgeryHernia AbdominalInguinal herniaSurgical meshC-Reactive Proteinbiology.proteinSurgeryFemalebusinessAbdominal surgerymedicine.drugLangenbeck's archives of surgery
researchProduct

Eight-point compass rose underlay technique in 72 consecutive elderly patients with large incisional hernia

2011

Summary Background Repair of incisional hernia (IH) in the elderly is a challenge for the surgeon. Primary closure is preferable but is not always possible because of high recurrence rates of IH repaired without a prosthesis and/or possible respiratory and cardiovascular complications due to extreme tension of the margins. We report our experience with underlay mesh placement in elderly patients with large IH. Methods A total of 72 patients from January 2003 to December 2009 underwent IH repair involving placement of an intraperitoneal Gore® DualMesh® prosthesis. The prosthesis was first anchored at eight points in a compass rose pattern using a Gore® suture passer and then firmly secured t…

medicine.medical_specialtyIncisional herniamedicine.medical_treatmentHigh-risk elderly patientAdhesion (medicine)lcsh:GeriatricsProsthesisePTFE meshTension-free techniqueAbdominal wallLarge ventral herniaSuture (anatomy)PneumoperitoneumePTFE mesh; High-risk elderly patients; Large ventral hernia; Suture passer; Tension-free techniquemedicineLaparoscopyhigh-risk elderly patientsSuture passermedicine.diagnostic_testbusiness.industrymedicine.diseaseSurgeryDissectionlcsh:RC952-954.6Settore MED/18 - Chirurgia Generalemedicine.anatomical_structureGeriatrics and Gerontologybusiness
researchProduct

Gastric Banding for Treatment of Morbid Obesity: Preliminary Results.

1995

Background: gastric banding (GB) has been used for treatment of morbid obesity. Methods: a banding device, introduced by Broadbent and consisting of a self-blocking nylon strip covered with a silicone tube, was used in 13 patients who have completed 1-year follow-up. This device was used for its mechanical properties, biocompatibility, ease of insertion and low cost. Results: at 1 year, mean excess weight loss was 51.6%, with all but one patient losing more than 25% of excess weight. Associated illnesses resolved. There were two complications (15%): one patient required band removal for self-induced vomiting and one patient required repair of an incisional hernia. Conclusions: GB has had go…

medicine.medical_specialtyNutrition and DieteticsGastric bandingbusiness.industryIncisional herniaEndocrinology Diabetes and MetabolismGeneral surgeryBand removalmedicine.diseaseSurgeryMorbid obesityStoma (medicine)VomitingMedicineSurgerymedicine.symptomPouchbusinessSilicone tubeObesity surgery
researchProduct

Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: A comparison of six diffe…

2012

Abstract Background An ideal prosthetic mesh for incisional hernia repair should mimic the anisotropic compliance of the abdominal wall, and at lower loads should exhibit higher distensibility without impairment of safety at higher loads. This study evaluated the biomechanical properties of six meshes in a rabbit model. Methods New Zealand white rabbits were used for this study. Two meshes of the same brand (Ethicon Physiomesh™, Bard Composix ® L/P, Gore Dualmesh ® , Bard Sepramesh ® , Ethicon Proceed ® or Parietex™ Composite) were implanted into each animal for assessment of intra-abdominal hernia repair, with a total of ten meshes per group. Twelve weeks after implantation, the abdominal …

medicine.medical_specialtyPolyestersmedicine.medical_treatmentBiomedical EngineeringBiophysicsAdhesion (medicine)PolypropylenesDioxanesAbdominal wallAdhesivesMaterials TestingAnimalsMedicinePeritoneal CavityPhysiological reactionHerniorrhaphyMechanical PhenomenaWound HealingMathematical approximationbusiness.industryAbdominal WallIncisional hernia repairProstheses and ImplantsHernia repairmedicine.diseaseBiomechanical PhenomenaSurgeryCompliance (physiology)medicine.anatomical_structurePolydioxanoneRabbit modelFemaleRabbitsbusinessPorosityMedical Engineering & Physics
researchProduct

Progrip self-gripping mesh in Rives-Stoppa repair: Are there any differences in outcomes versus a retromuscular polypropylene mesh fixed with sutures…

2017

Highlights • The Rives-Stoppa technique is an excellent repair in midline incisional hernia. • Prospective comparative analysis between retromuscular Self-gripping mesh and PPL fixed with sutures. • Self-gripping mesh is related to less postoperative pain the first 48 h after repair. • There were more postoperative hematomas in Non-Progrip group. • There were no differences in hernia recurrence in both groups.

medicine.medical_specialtySelf-gripping meshIncisional hernia030230 surgery03 medical and health sciencesMesh repair0302 clinical medicineHematomamedicineCase SeriesRives techniqueIncisional herniabusiness.industryPostoperative complicationPerioperativemedicine.diseaseSurgerybody regionsPolypropylene meshsurgical procedures operative030220 oncology & carcinogenesisSeromaOperative timeSurgeryRives-Stoppa repairbusinessCase seriesInternational Journal of Surgery Case Reports
researchProduct

Abdominal wall incisional hernia repair improves respiratory function: results after 3 years of follow-up

2020

Abstract Purpose Hernias severely impact patient quality of life (QoL), and 80% of patients require a surgical operation. Moreover, hernias are responsible for respiratory function alterations. This study aims to investigate the postoperative alterations in respiratory function after open ventral hernia repair in patients with incisional hernia. Methods Patients operated on at the Policlinico “Paolo Giaccone” at Palermo University Hospital between January 2015 and December 2016 were identified in a prospective database. Fifty-one patients were enrolled in the study. The respiratory outcome measures used were forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), FEV1/FVC ratio…

medicine.medical_specialtyVital capacityIncisional herniaVentral hernia repairAbdominal wallFEV1/FVC ratioQuality of lifemedicineHumansRespiratory functionRespiratory systemRespiratory outcomeIncisional herniaHerniorrhaphybusiness.industryAbdominal Wallrespiratory systemmedicine.diseaseHernia Ventralrespiratory tract diseasesSurgerymedicine.anatomical_structureQuality of LifeOriginal ArticleSurgerybusinesscirculatory and respiratory physiologyFollow-Up StudiesAbdominal surgery
researchProduct

Topic: Incisional Hernia - "Difficult case" as specialistic case: real loss of substance, multi recurrences, infections, fistulas, lombocel, burst ab…

2015

medicine.medical_specialtybusiness.industryIncisional herniaGeneral surgerymedicineMEDLINESurgerybusinessmedicine.diseaseBurst abdomenAbdominal surgerySurgeryHernia : the journal of hernias and abdominal wall surgery
researchProduct

Preoperative Botulinum Toxin and Progressive Pneumoperitoneum in Loss of Domain Hernias-Our First 100 Cases

2020

Objectives: Preoperative botulinum toxin type A (BT) and progressive pneumoperitoneum (PPP) are useful tools in the preparation of patients with loss of domain hernias (LODH). The purpose of our retrospective study is to report our experience in the treatment of 100 consecutive patients with LODH, with the combined use of these techniques. Methods: Of the 753 patients operated on for ventral incisional hernia between June 2010 and December 2018 in our hospital, 100 patients with LODH were analyzed retrospectively. Diameters of abdominal cavity and hernia sac, and volumes of incisional hernia (VIH) and abdominal cavity (VAC) were calculated from CT scan, based on the index of Tanaka. Results…

medicine.medical_specialtyincisional herniapreoperative progressive pneumoperitoneumIncisional herniaCombined uselcsh:SurgeryAbdominal cavity03 medical and health sciences0302 clinical medicinePneumoperitoneumMedicineHerniaTransversus abdominisbotulinum toxinOriginal Researchlarge incisional herniabusiness.industryventral herniaRetrospective cohort studylcsh:RD1-811medicine.diseaseBotulinum toxinSurgerymedicine.anatomical_structure030220 oncology & carcinogenesisSurgerybusiness030217 neurology & neurosurgerymedicine.drug
researchProduct