Search results for "Inde"
showing 10 items of 7365 documents
High Plasma Concentration of Non-Esterified Polyunsaturated Fatty Acids Is a Specific Feature of Severe COVID-19 Pneumonia
2020
Background: The pathogenesis of severe COVID-19 is frequently associated with an uncontrolled inflammatory response. Severe forms of COVID-19 appear to be more frequent in obese patients, but an association with metabolic disorders is not established. Here, we focused on lipoprotein metabolism in patients hospitalized for severe pneumonia, depending on COVID-19 status. Methods: Thirty-four non-COVID-19 and 27 COVID-19 patients with severe pneumonia were enrolled. Most of them required intensive care. Plasma lipid levels, lipoprotein metabolism, and clinical and biological features were assessed. Findings: Despite similar initial metabolic comorbidities and respiratory severity, COVID-19 pat…
Static measurements of refractive index increments at 633 nm with a modified refractive index detector
1985
A R 401 Waters Assoc. differential refractometer has been modified to obtain the variation of refractive index increments, dn/dc, of polymer solutions at 633 nm. The introduced modifications were in the sample injection system and in the light source. The performance of the modified refractometer both with aqueous and organic solutions is analyzed. In order to localize a conformational transition in lysozyme, the dependence of dn/dc on temperature for lysozyme solutions in phosphate buffer is studied. Similarly, (dn/dc)k values for the ternary n-alkane/butanone/poly(dimethyl siloxane) systems over the whole composition range of the binary solvent mixtures are evaluated.
Conformational analysis of α,β-poly(N-hydroxyethyl)-dl-aspartamide (PHEA) and α,β-polyasparthydrazide (PAHy) polymers in aqueous solution
1998
Abstract α,β-Poly(N-hydroxyethyl)- dl -aspartamide (PHEA) and α,β-polyasparthydrazide (PAHy) are synthetic polymers previously studied for biomedical applications. We report here the results of a small-angle X-ray scattering analysis carried out on these two macromolecules in aqueous solution. The data obtained indicate that the two polymers assume remarkably different conformations in aqueous solution, although the backbone is supposed to be the same for the two chains. PHEA can be represented by a random coil conformation, whereas PAHy can be described in terms of an elliptical cylinder characterized by an almost planar structural arrangement with the backbone refolded on itself in a fash…
Gas-liquid chromatography and lipophilicity of esters of benzoic acids
1987
Abstract The use of gas-liquid chromatographic (GLC) retention indices for the determination of lipophilicity was studied for a series of alkyl and arylalkyl esters of substituted benzoic acids. The regression relationships between the logarithms of the partition coefficients and the retention characteristics measured on two cpillary columns, SE-30 and OV-351, were evaluated. The behaviour of arylalkyl esters and of alkyl esters cannot be expressed in terms of a single regression equation. This is probably a consequence of the effect of the intramolecular hydrophobic interaction upon the retention of arylalkyl esters under GLC conditions. An analysis of the isokinetic relationships revealed…
Determination of indoor air quality of a phytosanitary plant.
2011
A new methodology has been developed to determine volatile organic compounds (VOCs) and pesticides in ambient air using membrane based devices as passive samplers. Pesticides were determined by gas chromatography with mass spectrometry detection (GC-MS) after their microwave-assisted extraction (MAE) from the passive sampler and the required clean-up. On the other hand, VOCs were also caught with the same samplers and directly determined by head space (HS) coupled to GC-MS. The use of samplers filled with florisil and activated carbon allows us to catch with a simple device both, VOCs and pesticides, with a high vapor pressure. Results obtained in the deployment of samplers in different sit…
Mechanical Behavior of Concrete Columns Confined by Laterally Pre-Tensioned FRP
2011
This paper presents the results of an experimental investigation of concrete columns confined by a wound pre-tensioned carbon filament yarn. Yarn winding equipment was developed in the Institute of Polymer Mechanics with the ability to set the desired pre-tension force and thereby producing confined concrete specimens with different initial lateral pressure. It is shown that initial lateral pressure increases the axial stress at which intense internal cracking of the concrete develops.
Gas chromatography of homologous esters
1984
Abstract The gas chromatographic retention behaviour of the butanoyl and 2-, 3- and 4-chlorobutanoyl esters of C 3 —C 5 saturated aliphatic branched-chain and unsaturated C 3 —C 6 alcohols on SE-30 and OV-351 glass capillary columns operated iso-thermally at several temperatures is reported. Retention index increments at 80, 120 and 160°C show the effects of chain branching and the olefinic and acetylenic unsaturation in the alkyl chain and the effect of the position of the chlorine substituent in the acyl chain. The results are compared with the behaviour of the corresponding n -alkyl esters and the chlorinated propanoyl esters.
Gaschromatographisch-massenspektrometrische identifizierung der durch umsetzung von aminen mit isocyanaten gebildeten harnstoffderivate
1977
Abstract Gas chromatographic-mass spectrometric identification of urea derivatives formed by the reaction of amines with isocyanates N,N′-Di- and N,N′,N′-trisubstituted ureas constitute suitable derivatives for the gas chromatographic (GC) determination of primary and secondary amines. The GC identification of N- tert. -butyl-,N′,N′-alkyl urea derivatives presented in the first communication has been succesfully confirmed by mass spectrometry (MS) and mass fragmentometry. The reproduced mass spectra of six N- tert. -butyl-,N′,N′-alkyl ureas were interpreted according to the decomposition mechanisms of less complicated alkyl ureas known from the literature. Using combined GC-MS the detection…
Allylated cyclodextrins as effective affinity materials in chemical sensing of volatile aromatic hydrocarbons using an optical planar Bragg grating s…
2013
We report on the application of perallyl-substituted α-, β- and γ-cyclodextrins to an optical planar Bragg grating refractive index sensor for the effective sensitization of the sensor for airborne volatile aromatic hydrocarbons. Thereby, the emphasis of this work lies on the comparison of the different cyclodextrin types regarding their suitability as affinity material assessed by the sensors sensitivity and response behavior. The opto-chemical sensor device showed an immediate and quick response to the application of the investigated analytes benzene, toluene and m-xylene as well as a linear dependence on the concentration of those analytes. Studies on the sensors sensitivity depending on…
Wetting of mesoscopic soft cylinders: structure and layering transitions.
1998
The wetting of soft mesoscopic long-chain particles is studied. As a model system, a cylindrical brush with poly(vinyl)pyridine side chains on the water surface is characterized by isotherms and x-ray reflectivity. The forces from the two planar interfaces and the intra- and interparticle interactions are all of comparable magnitude. Two layering transitions occur, one from the monolayer to the double layer, the next to a homogeneous multilayer. The hard wall from which layering starts is the smooth polymer/air interface. Indeed, they particles in the top layer of both the double- and the multilayer have their cylinder axis parallel to the surface and are laterally compressed. In contrast, …