Characterization of materials toward toluene traces detection for air quality monitoring and lung cancer diagnosis

2017

International audience; The aim of this work was to identify a nanoporous material able to trap toluene traces in order to develop a gas detection device for indoor air quality monitoring or biomedical diagnosis. A set of various adsorbents such as zeolites and activated carbon microspheres was studied here. First a detailed characterization of their porous properties was performed by nitrogen adsorption. Then adsorption of toluene and other interfering compounds which can selectively adsorbed with it, such as water and carbon dioxide, was studied in order to select the most suitable material. Results revealed that the activatedcarbon microspheres W5 and the zeolite NaY, which exhibit high …

Materials science02 engineering and technology010402 general chemistry01 natural sciences[SPI.MAT]Engineering Sciences [physics]/Materialschemistry.chemical_compoundIndoor air qualityAdsorptionmedicineOrganic chemistryGeneral Materials Science[SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsZeolitePorosityIndoor pollution[SPI.ACOU]Engineering Sciences [physics]/Acoustics [physics.class-ph]NanoporousMicroporous material021001 nanoscience & nanotechnologyCondensed Matter PhysicsToluene0104 chemical scienceschemistryChemical engineeringZeolitesAdsorptionLung cancer0210 nano-technologyCarbon microspheresTolueneActivated carbonmedicine.drugMaterials Chemistry and Physics
researchProduct

An Experimental Investigation on the Air Permeability of Passive Ventilation Grilles

2015

Abstract The need of increasing both energy saving and acoustic insulation has leaded to the design of lowest air permeability frames resulting in the worsening of indoor air quality. Moreover, sometime in several civil-use existing buildings (i.e. schools or houses, historical buildings) mechanical ventilation systems cannot be installed due to non-removable constraints. In these cases, passive ventilation grilles are a cheap and effective solution for the ventilation. This work deals with an in-depth experimental analysis about the air permeability values measured over a set of passive ventilation grilles available on the market. Obtained results often showed performances very far to thos…

Mechanical ventilationEngineeringbusiness.industrymedicine.medical_treatmentventilation grilleEnvironmental engineeringEnergy recovery ventilationNatural ventilationEffective solutionEnergy (all)Indoor air qualityEnergy(all)energy savingAir permeability specific surfacePassive ventilationEnergy saving; Indoor air quality; Ventilation grilles; Energy (all)medicineventilation grillesDuct (flow)Energy saving; Indoor air quality; Ventilation grillesbusinessindoor air qualityMarine engineeringEnergy Procedia
researchProduct

Visually low-impacting methods for the measurement of parameters related to IAQ risk indicators in exhibition halls

2021

Microclimate for cultural heritage plays a fundamental role in the degradation process of artefacts exhibited in museums. Generally, the Indoor Air Quality (IAQ) monitoring inside museums is based on conventional measurements of thermo-hygrometry parameters and longtime averaged measurements of atmospheric pollutants’ concentration. Unfortunately, all these approaches require electric supply and are usually characterized by a noticeable visual impact on the exhibition space, which clearly negatively affects the visitors’ experience. This paper intends to revisit and discuss a methodology (and its test application on field, to estimate the risk of damage of three artefacts displayed in an ol…

Museums indoor air quality off-line sensors low visual impact corrosion risk artefact preservation visitors ‘comfort
researchProduct

A Systematic Review of Air Quality Sensors, Guidelines, and Measurement Studies for Indoor Air Quality Management

2020

The existence of indoor air pollutants—such as ozone, carbon monoxide, carbon dioxide, sulfur dioxide, nitrogen dioxide, particulate matter, and total volatile organic compounds—is evidently a critical issue for human health. Over the past decade, various international agencies have continually refined and updated the quantitative air quality guidelines and standards in order to meet the requirements for indoor air quality management. This paper first provides a systematic review of the existing air quality guidelines and standards implemented by different agencies, which include the Ambient Air Quality Standards (NAAQS); the World Health Organization (WHO); the Occupational Safety and Heal…

Ozone010504 meteorology & atmospheric sciencesmedia_common.quotation_subjectGeography Planning and DevelopmentTJ807-830010501 environmental sciencesManagement Monitoring Policy and LawTD194-19501 natural sciencesOccupational safety and healthRenewable energy sourcesTransport engineeringchemistry.chemical_compoundSick building syndromeIndoor air qualityASHRAE 90.1Quality (business)GE1-350guidelinesAir quality index0105 earth and related environmental sciencesmedia_commonPollutantEnvironmental effects of industries and plantsRenewable Energy Sustainability and the Environmentlow-cost sensorEnvironmental scienceschemistrypollutantsstandardsEnvironmental sciencesick building syndromeindoor air qualitySustainability
researchProduct

Three Hours Ahead Prevision of SO2 Pollutant Concentration Using an Elman Neural based Forecaster

2008

Abstract Indoor air quality near the industrial site is tightly joined to pollutant concentration level, since outdoor pollution heavily influences air quality and, consequently, inhabitants health. A pollution management system is essential for health protection. Automatic air quality management systems have became an important research issue with strong implications for inhabitants’ health. In this paper an automatic forecaster based on neural networks for SO 2 concentration prevision is proposed. The analyzed area covers different small towns near the industrial site of Priolo, in the south of the world. Among these towns, Melilli was the first town in Italy that was evacuated for high l…

PollutionPollutantEnvironmental EngineeringMeteorologyArtificial neural networkOperations researchWarning systemStochastic modellingmedia_common.quotation_subjectGeography Planning and DevelopmentRecurrent neural networkBuilding and ConstructionModeling and measurementRecurrent neural networkIndoor air qualityAir qualityEnvironmental scienceAir quality indexCivil and Structural Engineeringmedia_commonForecasting
researchProduct

Studio sperimentale della qualità dell'aria in una unità abitativa dotata di impianto di ventilazione con scambiatore di recupero ad alta efficienza

2008

Qualità dell'aria interna Ventilazione Scambiatore di recuperoVentilazioneSettore ING-IND/11 - Fisica Tecnica AmbientaleIndoor Air Quality
researchProduct

INQUINAMENTO INDOOR DA RADON. UNA APPLICAZIONE DELLE RETI BAYESIANE A SUPPORTO DELLA DIAGNOSI

2010

Nel quadro più generale della tematica del controllo della qualità ambientale e più in particolare dell’Indoor Air Quality, la presente relazione riporta lo studio di un fenomeno di inquinamento da radon riguardante la scuola “G. Mancino” di Palermo. Lo spunto viene offerto dal fatto che nel 2005, nel corso di un monitoraggio della radioattività ambientale di Palermo, i tecnici dell’ARPA Sicilia hanno rilevato in questa scuola elementare degli anni ’30, livelli di radon indoor molto superiori ai limiti di legge fissati dal D.Lgs. 241/2000. Nella prima fase, dopo lo studio delle caratteristiche tipologiche e costruttive del plesso e l’acquisizione dei dati di misura pregressi, si è proceduto…

Qualità Indoor Air Quality Radon Analisi Meccanismi inquinamento Reti BayesianeSettore ICAR/11 - Produzione Edilizia
researchProduct

Determinazione della qualita’ dell’aria all’interno di sale operatorie mediante “naso elettronico”

2006

Sale operatorieSettore ING-IND/11 - Fisica Tecnica AmbientaleIndoor Air Qualitynaso elettronico
researchProduct

Ventilation rates and unsatisfied percentage from indoor CO2 concentration.

2011

This work reports the results of a survey carried out on a hall in a historic building in Palermo (Italy) with the aim of assessing the air quality by means of objective measurement of carbon dioxide (CO2) concentration and its subjective evaluation through a questionnaire. The measured values of CO2 concentration were compared with those evaluated using the Meckler equation under steady-state conditions, having verified necessary parameters such as the constancy of the indoor and outdoor CO2 levels and the uniformity of the CO2 generation rate for all the occupants. The positive correspondence between measured and calculated results allowed us to utilise, under differing circum- stances, t…

Settore ING-IND/11 - Fisica Tecnica AmbientaleBuilding occupancy - Carbon dioxide - Demand-controlled ventilation - Indoor air quality - Natural ventilation
researchProduct

Iekštelpu gaisa kvalitātes novērtējums publiskās izklaides vietās

2021

Bakalaura darbā “Iekštelpu gaisa kvalitātes novērtējums publiskās izklaides vietās” ir aprakstīti iekštelpu gaisa kvalitāti ietekmējošie faktori, kā arī apskatīti būtiskākie iekštelpu gaisa piesārņotāji. Ir veikts raksturojums veselības problēmām un slimībām, ko izraisa dažādas gaisu piesārņojošās vielas un savienojumi. Iekštelpu gaisa pazemināta kvalitāte ir nozīmīga problēma, jo mūsdienās liela daļa Eiropas iedzīvotāju līdz pat 90% savas dzīves pavada iekštelpās. Darba gaitā ir novērtēta iekštelpu gaisu piesārņojošo vielu koncentrācija gaisā publiskā izklaides vietā – kinoteātrī, kā arī veikts iekštelpu mikroklimatisko apstākļu izvērtējums.

Vides zinātneventilācijapiesārņojošās vielasgaisa kvalitāteindoor air quality