Search results for "Inductively coupled plasma mass spectrometry"

showing 10 items of 95 documents

Determination of Trace Elements and Elemental Species Using Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

2012

Trace (semiology)SpeciationChromatographyChemistrymedia_common.quotation_subjectIsotope dilutionInductively coupled plasma mass spectrometrymedia_commonIsotopic Analysis
researchProduct

Development of accurate mass spectrometric routine and reference methods for the determination of trace amounts of iridium and rhodium in photographi…

1999

For the determination of trace amounts of iridium and rhodium in photographic emulsions different sample treatment procedures were coupled with inductively coupled plasma mass spectrometry (ICP-MS) and, for iridium, also with negative thermal ionisation isotope dilution mass spectrometry (NTI-IDMS) and ICP-IDMS. IDMS determinations of iridium were carried out using an enriched 191Ir spike solution. Elimination of the silver matrix was established for both mass spectrometric methods, which prevents corresponding memory effects in the ICP-MS system and is essential for the formation of IrO2 - thermal ions, respectively. For NTI-MS measurements, the gelatine matrix of the emulsion must also be…

Trace AmountsAnalytical chemistrychemistry.chemical_elementIsotope dilutionMass spectrometry/dk/atira/pure/sustainabledevelopmentgoals/clean_water_and_sanitationAnalytical ChemistryMatrix (chemical analysis)chemistrySample preparationIridiumPhotographic emulsionSDG 6 - Clean Water and SanitationInductively coupled plasma mass spectrometrySpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Determination of extremely low (236)U/(238)U isotope ratios in environmental samples by sector-field inductively coupled plasma mass spectrometry usi…

2005

A method by inductively coupled plasma mass spectrometry (ICP-MS) was developed which allows the measurement of (236)U at concentration ranges down to 3 x 10(-14)g g(-1) and extremely low (236)U/(238)U isotope ratios in soil samples of 10(-7). By using the high-efficiency solution introduction system APEX in connection with a sector-field ICP-MS a sensitivity of more than 5,000 counts fg(-1) uranium was achieved. The use of an aerosol desolvating unit reduced the formation rate of uranium hydride ions UH(+)/U(+) down to a level of 10(-6). An abundance sensitivity of 3 x 10(-7) was observed for (236)U/(238)U isotope ratio measurements at mass resolution 4000. The detection limit for (236)U a…

Uranium hydrideRadioactive FalloutRadioisotopesIsotopeRepublic of BelarusHealth Toxicology and MutagenesisRadiochemistrychemistry.chemical_elementGeneral MedicineUraniumPollutionMass SpectrometryUranium-236chemistry.chemical_compoundUranium-238chemistryRadiation MonitoringEnvironmental ChemistrySoil horizonSoil Pollutants RadioactiveUraniumEnvironmental PollutionWaste Management and DisposalInductively coupled plasma mass spectrometryIsotope analysisJournal of environmental radioactivity
researchProduct

Searching the most appropriate sample pretreatment for the elemental analysis of wines by inductively coupled plasma-based techniques.

2008

Different sample preparation methods were evaluated for the simultaneous multielement analysis of wine samples by inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS). Microwave-assisted digestion in closed vessel, thermal digestion in open reactor, and direct sample dilution were considered for the determination of Li, Be, Na, Mg, Al, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Sr, Y, Mo, Cd, Ba, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Tl, Pb, and Bi in 12 samples of red wine from Valencia and Utiel-Requena protected designation of origin. ICP-MS allows the determination of 17 elements in most…

WinebiologyChemistryAnalytical chemistryWineGeneral Chemistrybiology.organism_classificationDecompositionChemistry Techniques AnalyticalMass SpectrometryTrace ElementsElemental analysisInductively coupled plasma atomic emission spectroscopySample preparationInductively coupled plasmaGeneral Agricultural and Biological SciencesMicrowavesValenciaInductively coupled plasma mass spectrometryJournal of agricultural and food chemistry
researchProduct

Speciation of the oxidation states of plutonium in aqueous solutions by UV/Vis spectroscopy, CE-ICP-MS and CE-RIMS

2007

For the speciation of the plutonium oxidation states in aqueous solutions, the online coupling of capillary electrophoresis (CE) with inductively coupled plasma mass spectrometry (ICP-MS) has been developed. Depending on the radius/electrical charge ratio, the oxidation states III, IV, V, and VI of plutonium are separated by CE, based on the different migration times through the capillary and are detected by ICP-MS. The detection limit is 20 ppb,i.e.109–1010atoms (10-12–10-13g) for one oxidation state with an uncertainty of the reproducibility of the migration times of ≤1% and ≤5% for the peak area. The redox kinetics of the different plutonium oxidation states in the presence of humic subs…

chemistry.chemical_classificationAqueous solutionInorganic chemistryAnalytical chemistrychemistry.chemical_elementMass spectrometryRedoxPlutoniumCapillary electrophoresischemistryOxidation stateHumic acidPhysical and Theoretical ChemistryInductively coupled plasma mass spectrometryRadiochimica Acta
researchProduct

Development of a Matrix-Matched Sphalerite Reference Material (MUL-ZnS-1) for Calibration of In Situ Trace Element Measurements by Laser Ablation-Ind…

2016

Sphalerite (ZnS) is an abundant ore mineral and an important carrier of elements such as Ge, Ga and In used in high-technology applications. In situ measurements of trace elements in natural sphalerite samples using LA-ICP-MS are hampered by a lack of homogenous matrix-matched sulfide reference materials available for calibration. The preparation of the MUL-ZnS1 calibration material containing the trace elements V, Cr, Mn, Co, Ni, Cu, Ga, Ge, As, Se, Mo, Ag, Cd, In, Sn, Sb, Tl and Pb besides Zn, Fe and S is reported. Commercially available ZnS, FeS, CdS products were used as the major components, whereas the trace elements were added by doping with single-element ICP-MS standard solutions a…

chemistry.chemical_classificationArgonLaser ablationMaterials scienceSulfide010401 analytical chemistryAnalytical chemistryTrace elementchemistry.chemical_elementGeologyElectron microprobeengineering.material010502 geochemistry & geophysics01 natural sciences0104 chemical sciencesSphaleritechemistryGeochemistry and PetrologyengineeringInductively coupled plasma mass spectrometryPowder mixture0105 earth and related environmental sciencesGeostandards and Geoanalytical Research
researchProduct

Iodine speciation in rain, snow and aerosols

2008

Iodine oxides, such as iodate, should be the only thermodynamically stable sink species for iodine in the troposphere. However, field observations have increasingly found very little iodate and significant amounts of iodide and soluble organically bound iodine (SOI) in precipitation and aerosols. The aim of this study was to investigate iodine speciation, including the organic fraction, in rain, snow, and aerosols in an attempt to further clarify aqueous phase iodine chemistry. Diurnal aerosol samples were taken with a 5 stage cascade impactor and a virtual impactor (PM<sub>2.5</sub>) from the Mace Head research station, Ireland, during summer 2006. Rain was collected from Austr…

chemistry.chemical_classificationAtmospheric ScienceIodidechemistry.chemical_elementIodineSnowlcsh:QC1-999Aerosollcsh:Chemistrychemistry.chemical_compoundchemistrylcsh:QD1-999Environmental chemistryOrganic matterInductively coupled plasma mass spectrometryRain and snow mixedIodatelcsh:PhysicsAtmospheric Chemistry and Physics
researchProduct

Trace element determination in sediments: a comparative study between neutron activation analysis (NAA) and inductively coupled plasma-mass spectrome…

2000

An inductively coupled plasma-mass spectrometry (ICP-MS) method has been employed for trace element determination in five real sediment samples and a standard reference material. These samples were mineralized by dry ashing at 550°C and fused at 1100°C for 30 min with lithium metaborate. Dissolved samples were measured by a semiquantitative methodology with external calibration and with Rh as an internal standard. More than 50 elements have been measured. As a reference technique, a direct analysis of the solid samples was carried out by neutron activation analysis. Results obtained by ICP-MS have been compared with those obtained by neutron activation analysis (NAA) by applying the paired …

chemistry.chemical_compoundAshingChemistryAnalytical chemistryTrace elementSample preparationNeutron activation analysisMass spectrometryInductively coupled plasma mass spectrometrySpectroscopyAnalytical ChemistryNeutron activationLithium metaborateMicrochemical Journal
researchProduct

Nano‐Powdered Calcium Carbonate Reference Materials: Significant Progress for Microanalysis?

2019

chemistry.chemical_compoundCalcium carbonateMaterials sciencechemistryGeochemistry and PetrologyLaser ablation inductively coupled plasma mass spectrometryHomogeneity (statistics)Nano-CarbonateGeologyMicroanalysisNuclear chemistryGeostandards and Geoanalytical Research
researchProduct

Depth profiling of Pu, 241Am and 137Cs in soils from southern Belarus measured by ICP-MS and alpha- and gamma-spectrometry

2003

The depth distribution of plutonium, americium, and Cs-137 originating front the 1986 accident at the Chernobyl Nuclear Power Plant (NPP) was investigated in several soil profiles in the vicinity from Belarus. The vertical migration of transuranic elements in soils typical of the 30 km relocation area around Chernobyl NPP was studied using inductively coupled plasma mass spectrometry (ICP-MS), alpha spectrometry, and gamma spectrometry. Transuranic concentrations in upper soil layers ranged from 6 x 10(-12) g g(-1) to 6 x 10(-10) g g(-1) for plutonium and from 1.8 x 10(-13) g g(-1) to 1.6 x 10(-11) g g(-1) for americium. These concentrations correspond to specific activities of Pu239+240 of…

chemistry.chemical_elementCesiumAmericiumManagement Monitoring Policy and LawMass spectrometryMass SpectrometrySoil Pollutants RadioactiveInductively coupled plasma mass spectrometryRadionuclideAmericiumRadiochemistryPublic Health Environmental and Occupational HealthGeneral MedicinePlutoniumPlutoniumJTransuranic wastechemistryCesium RadioisotopesEnvironmental chemistrySoil waterSoil horizonddc:333.7Radioactive Hazard ReleaseUkraineEnvironmental MonitoringPower Plants
researchProduct