Search results for "Instrument"
showing 10 items of 5652 documents
Electronic noses : specify or disappear
2000
Abstract When the quality control is achieved by using GC or GC/MS, the apparatus must comply with the applicable norms, but what about “electronic noses”? End users demand for formal specifications for selectivity, sensitivity, repeatability and sample throughput. The behavioural modelling of electronic olfactometers may provide specifications for these required parameters. This will allow both the measure itself, and evaluate the influence of the experimental errors on the sample classification. Users may expect to find a methodology allowing the performances of systems to be checked before any final decision and during routine use. We have demonstrated that the system sensitivity and log…
Influence of interfering gases on a carbon monoxide differential sensor based on SAW devices functionalized with cobalt and copper corroles
2021
International audience; <!--[if gte mso 9]><xml> <w:WordDocument> <w:View>Normal</w:View> <w:Zoom>0</w:Zoom> <w:TrackMoves/> <w:TrackFormatting/> <w:HyphenationZone>21</w:HyphenationZone> <w:PunctuationKerning/> <w:ValidateAgainstSchemas/> <w:SaveIfXMLInvalid>false</w:SaveIfXMLInvalid> <w:IgnoreMixedContent>false</w:IgnoreMixedContent> <w:AlwaysShowPlaceholderText>false</w:AlwaysShowPlaceholderText> <w:DoNotPromoteQF/> <w:LidThemeOther>FR</w:LidThemeOther> <w:Compatibility> <w:BreakWrappedTables/> <w:SnapToGridInCell/> <w:WrapTextWithPunct/> <w:UseAsianBreakRules/> <w:DontGrowAutofit/> <w:SplitPgBreakAndParaMark/> <w:EnableOpenTypeKe…
Noise characterization of analog to digital converters for amplitude and phase noise measurements
2017
International audience; Improvements on electronic technology in recent years have allowed the application of digital techniques in phase noise metrology where low noise and high accuracy are required, yielding flexibility in systems implementation and setup. This results in measurement systems with extended capabilities, additional functionalities and ease of use. In most digital schemes the Analog to Digital Converters (ADCs) set the ultimate performance of the system, therefore the proper selection of this component is a critical issue. Currently, the information available in literature describes in depth the ADC features only at frequency offsets far from the carrier. However, the perfo…
Equivalence of Open-Loop and Closed-Loop Operation of SAW Resonators and Delay Lines
2019
International audience; Surface acoustic wave (SAW) sensors in the form of two-port resonators or delay lines are widely used in various fields of application. The readout of such sensors is achieved by electronic systems operating either in an open-loop or in a closed-loop configuration. The mode of operation of the sensor system is usually chosen based on requirements like, e.g., bandwidth, dynamic range, linearity, costs, and immunity against environmental influences. Because the limit of detection (LOD) at the output of a sensor system is often one of the most important figures of merit, both readout structures, i.e., open-loop and closed-loop systems, are analyzed in terms of the minim…
Residual Phase Noise Measurement of Optical Second Harmonic Generation in PPLN Waveguides
2017
We report on the characterization, including residual phase noise and fractional frequency instability, of fiber-coupled PPLN non-linear crystals. These components are devoted to frequency doubling 871 nm light from an extended-cavity diode laser to produce a 435.5 nm beam, corresponding to the ytterbium ion electric quadrupole clock transition. We measure doubling efficiencies of up to 117.5 %/W. Using a Mach-Zehnder interferometer and an original noise rejection technique, the residual phase noise of the doublers is estimated to be lower than ${\rm -35\, dBrad^2/Hz}$ at 1 Hz, making these modules compatible with up-to-date optical clocks and ultra-stable cavities. The influence of externa…
Phase-Noise and Amplitude-Noise Measurement of DACs and DDSs
2019
This article proposes a method for the measurement of Phase Noise (PN, or PM noise) and Amplitude Noise (AN, or AM noise) of Digital-to-Analog Converters (DAC) and Direct Digital Synthesizers (DDS) based on modulation-index amplification. The carrier is first reduced by a controlled amount (30-40 dB) by adding a reference signal of nearly equal amplitude and opposite in phase. Then, residual carrier and noise sidebands are amplified and sent to a conventional PN analyzer. The main virtues of our method are: (i) the noise specs of the PN analyzer are relaxed by a factor equal to the carrier suppression ratio; and, (ii) the capability to measure the AN using a PN analyzer, with no need for th…
Frequency Stability Measurement of Cryogenic Sapphire Oscillators with a Multichannel Tracking DDS and the Two-Sample Covariance
2018
This article shows the first measurement of three 100 MHz signals exhibiting fluctuations from 2E-16 to parts in 1E-15 for integration time tau between 1 s and 1 day. Such stable signals are provided by three Cryogenic Sapphire Oscillators (CSOs) operating at about 10 GHz, also delivering the 100 MHz output via a dedicated synthesizer. The measurement is made possible by a 6-channel Tracking DDS (TDDS) and the two-sample covariance tool, used to estimate the Allan variance. The use of two TDDS channels per CSO enables high rejection of the instrument background noise. The covariance outperforms the Three-Cornered Hat (TCH) method in that the background converges to zero "out of the box," wi…
Immobilization of single-stranded DNA fragments to solid surfaces and their repeatable specific hybridization : covalent binding or adsorption ?
2004
Abstract The different steps of the immobilization process of single-stranded DNA (ssDNA) on surfaces by means of chemical grafting have been investigated using systematic measurements of grafting and hybridization densities by means of radioactive labelling. The immobilization by chemical grafting to a dense monomolecular layer of N-hydroxysuccinimidyl ester reactive functions attached to silica plates was performed from a dilute solution of amino-terminated oligonucleotides (10 μmol/l). The slow evaporation of the solvent allowed to increase the DNA grafting density by a factor of 10. A precise control of the rinsing process that followed the immobilization reaction allowed the discrimina…
Quantification of land-atmosphere exchanges of water, energy and carbon dioxide in space and time over the heterogeneous Barrax site
2008
International audience; To advance our understanding of land-atmosphere exchanges of water, energy and carbon dioxide (CO2) in space and time over heterogeneous land surfaces, two intensive field campaigns were carried out at the Barrax agricultural test site in Spain during 12-21 July 2004 (SPARC 2004) and 8-14 July 2005 (SEN2FLEX 2005) involving multiple field, satellite and airborne instruments for characterizing the state of the atmosphere, the vegetation and the soil from the visible to the microwave range of the spectrum. Part of the experimental area is a core site of area 25 km2, within which numerous crops are grown, on both irrigated and dry land, alongside fields of bare soil. Th…
Holes Interaction and Heterogeinity Distribution Effect for a Multiperforated Plate
2012
International audience; Originally used to protect classical sound absorbing materials from environmental degradation, multi-perforated plates are considered to be one of the next generation soundproof solutions. This paper investigates the effects of holes interaction and heterogeneity distribution on the acoustical properties of a multi-perforated plate. These effects are observable on the specimens with closely separated holes. Multi-perforated plates with different center-to-center holes distances (pitches) are built and tested using an impedance tube. The cases of closely separated holes are analyzed and compared to the cases of widely separated holes. It is observed that in the presen…