The electron cyclotron resonance ion source with arc-shaped coils concept
2012
The main limitation to further improve the performance of ECR ion sources is set by the magnet technology related to the multipole magnet field used for the closed minimum-B structure. The JYFL ion source group has sought different approaches to improve the strength of the minimum-B structure required for the production of highly charged ion beams. It was found out that such a configuration can be realized with arc shaped coils. The first prototype, electron cyclotron resonance ion source with arc-shaped coils (ARC-ECRIS), was constructed and tested at JYFL in 2006. It was confirmed that such an ion source can be used for the production of highly charged ion beams. Regardless of several cos…
The laser ion source trap for highest isobaric selectivity in online exotic isotope production
2010
The improvement in the performance of a conventional laser ion source in the laser ion source and trap (LIST) project is presented, which envisages installation of a repeller electrode and a linear Paul trap/ion guide structure. This approach promises highest isobaric purity and optimum temporal and spatial control of the radioactive ion beam produced at an online isotope separator facility. The functionality of the LIST was explored at the offline test separators of University of Mainz (UMz) and ISOLDE/CERN, using the UMz solid state laser system. Ionization efficiency and selectivity as well as time structure and transversal emittance of the produced ion beam was determined. Next step aft…
First experiments with gasdynamic ion source in CW mode.
2016
A new type of ECR ion source—a gasdynamic ECR ion source—has been recently developed at the Institute of Applied Physics. The main advantages of such device are extremely high ion beam current with a current density up to 600–700 emA/cm2 in combination with low emittance, i.e., normalized RMS emittance below 0.1 π mm mrad. Previous investigations were carried out in pulsed operation with 37.5 or 75 GHz gyrotron radiation with power up to 100 kW at SMIS 37 experimental facility. The present work demonstrates the first experience of operating the gasdynamic ECR ion source in CW mode. A test bench of SMIS 24 facility has been developed at IAP RAS. 24 GHz radiation of CW gyrotron was used for p…
Double einzel lens extraction for the JYFL 14 GHz ECR ion source designed with IBSimu
2013
In order to improve the performance of the JYFL 14 GHz electron cyclotron resonance ion source (ECRIS) and initiate low energy beam transport (LEBT) upgrade at the University of Jyvaskyla, Department of Physics (JYFL) accelerator laboratory, a new ion beam extraction system has been designed and installed. The development of the new extraction was performed with the ion optical code IBSimu, making it the first ECRIS extraction designed with the code. The measured performance of the new extraction is in good agreement with the simulations. Compared to the old extraction the new system provides improved beam quality, i.e. lower transverse emittance values and improved structure of beam profil…
The effect of rf pulse pattern on bremsstrahlung and ion current time evolution of an ECRIS.
2010
Time-resolved helium ion production and bremsstrahlung emission from JYFL 14 GHz ECRIS is presented with different radio frequency pulse lengths. rf on times are varied from 5 to 50 ms and rf off times from 10 to 1000 ms between different measurement sets. It is observed that the plasma breakdown occurs a few milliseconds after launching the rf power into the plasma chamber, and in the beginning of the rf pulses a preglow transient is seen. During this transient the ion beam currents are increased by several factors compared to a steady state situation. By adjusting the rf pulse separation the maximum ion beam currents can be maintained during the so-called preglow regime while the amount o…
ECRIS plasma spectroscopy with a high resolution spectrometer
2020
Electron Cyclotron Resonance Ion Source (ECRIS) plasmas contain high-energy electrons and highly charged ions implying that only noninvasive methods such as optical emission spectroscopy are reliable in their characterization. A high-resolution spectrometer (10 pm FWHM at 632 nm) enabling the detection of weak emission lines has been developed at University of Jyväskylä, Department of Physics (JYFL) for this purpose. Diagnostics results probing the densities of ions, neutral atoms, and the temperature of the cold electron population in the JYFL 14 GHz ECRIS are described. For example, it has been observed that the cold electron temperature drops from 40 eV to 20 eV when the extraction volta…
Simulation of H- ion source extraction systems for the Spallation Neutron Source with Ion Beam Simulator.
2012
A three-dimensional ion optical code IBSimu, which is being developed at the University of Jyväskylä, features positive and negative ion plasma extraction models and self-consistent space charge calculation. The code has been utilized for modeling the existing extraction system of the H(-) ion source of the Spallation Neutron Source. Simulation results are in good agreement with experimental data. A high-current extraction system with downstream electron dumping at intermediate energy has been designed. According to the simulations it provides lower emittance compared to the baseline system at H(-) currents exceeding 40 mA. A magnetic low energy beam transport section consisting of two sole…
Solid proton conductors as room-temperature gas sensors
1993
Ammonia-exchanged ceramic samples of beta alumina have been obtained from plasma-dispersed powders. The ionic conductivity is slightly affected by ion exchange, but the surface conductivity for the amonia-exchanged sample drastically changes in the presence of the water and ammonia vapours. The ammonia-doped xerogel of antimonic acid hydrate in the form of a thick film has been tested as a potentiometric ammonia sensor.
Charged colloidal model systems under confinement in slit geometry: a new setup for optical microscopic studies.
2013
A new experimental setup for optical microscopic studies of charged colloidal model systems under confinement between two flat walls is presented. The measurement cell consists of optically flat quartz substrates attached to piezo actuators. Those facilitate fast and flexible adjustment of the confining geometry. Optionally, the local cell height can be quantitatively controlled by in situ interferometric measurements. Proper choice of materials guarantees sufficient chemical inertia against contamination with salt ions. For efficient preparation of charged colloidal suspensions under strongly deionized conditions, the cell can be connected to a conventional pump circuit including a mixed b…
Time profile of ion pulses produced in a hot-cavity laser ion source.
2010
The time spreads of Mn ions produced by three-photon resonant ionization in a hot-cavity laser ion source are measured. A one-dimensional ion-transport model is developed to simulate the observed ion time structures. Assuming ions are generated with a Maxwellian velocity distribution and are guided by an axial electric field, the predictions of the model agree reasonably well with the experimental data and suggest that the ions are radially confined in the ion source and a substantial fraction of the ions in the transport tube are extracted.