Search results for "Instrumentation"
showing 10 items of 4914 documents
Solving Challenging Crystallographic Problems with Automated Electron Diffraction Tomography (ADT)
2016
Investigation of matrix effects in 193nm laser ablation-inductively coupled plasma-mass spectrometry analysis using reference glasses of different tr…
2012
Abstract The degree of transparency of glasses, which depends on the Fe content, may influence the ablation behavior during laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) analysis. To test possible matrix effects when using a 193 nm Nd:YAG laser, we have analyzed transparent and opaque NIST, BAM and USGS reference glasses. These reference materials are ideal for such investigations, because they are well characterized, most elements are homogeneously distributed at the micrometer scale, and their Fe content varies over a very large range, from 16 to 130,000 μg g− 1. Our measurements show that the fractionation factors of refractory and volatile lithophile elements, …
Actively mode-locked all-fiber laser by 5 MHz transmittance modulation of an acousto-optic tunable bandpass filter
2018
Active mode-locking of an all-fiber ring laser by transmittance modulation of an in-fiber acousto-optic tunable bandpass filter (AOTBF) is reported. Cavity loss modulation is achieved by full acousto-optic mode re-coupling cycle induced by standing flexural acoustic waves. The modulator permits the implementation of 28 dB of nonresonant light suppression, 1.4 nm of modulation bandwidth, 74% of modulation depth and 4.11 dB of optical loss in a 72.5 cm-long all-fiber configuration. The effects of the modulated AOTBF on the laser performance are investigated. Transform-limited optical pulses of 8.8 ps temporal width and 6.0 W peak power were obtained at 4.87 MHz repetition rate.
Refractory metal reactivity towards oxide surface : W/TiO2(1 1 0) case.
2006
International audience; Reactivity of deposited tungsten towards TiO2(1 1 0) surface was studied using synchrotron radiation photoemission spectroscopy (both core levels, valence band and resonant photoemission) on Materials Science Beamline at ELETTRA. W depositions carried out at room temperature on TiO2(1 1 0) surface give rise to an interfacial reaction which leads to a metastable situation due to kinetic limitations. Annealing induces chemical changes which are function of the initial coverage; for fractional coverage, annealing induces completion of oxidation of deposit whereas reduction to metallic tungsten occurs for highest coverage. These results demonstrate that interaction of W …
Luminescence and EPR spectroscopy of neutron-irradiated single crystals of magnesium aluminium spinel
2016
Abstract Neutron irradiated single crystals of stoichiometric MgAl 2 O 4 and MgAl 2 O 4 :Mn 2+ (0.15 wt. %) were studied using the methods of luminescence spectroscopy and versions of electron paramagnetic resonance. In stoichiometric MgAl 2 O 4 :Mn 2+ single crystals, the transition of a part of manganese impurity ions from tetrahedral to octahedral coordination, caused by irradiation with fast fission neutrons, is detected using photoluminescence spectra. This fact confirms the partial inversion of a normal spinel due to neutron-irradiation. Using pulse EPR technique it is shown that an electron in the field of oxygen vacancy (i.e. from neutron-irradiation induced F + centres, which are s…
Temperature Sensor Based on Colloidal Quantum Dots PMMA Nanocomposite Waveguides
2012
In this paper, integrated temperature sensors based on active nanocomposite planar waveguides are presented. The nanocomposites consist of cadmium selenide (CdSe) and cadmium telluride (CdTe) quantum dots (QDs) embedded in a polymethylmethacrylate (PMMA) matrix. When the samples are heated in a temperature range from 25$^{circ}{rm C}$ to 50 $^{circ}{rm C}$, the waveguided photoluminescence of QDs suffers from a strong intensity decrease, which is approximately quadratic dependent on temperature. Moreover, the wavelength peak of the waveguided emission spectrum of CdTe-PMMA shows a blue shift of 0.25 ${rm nm}/^{circ}{rm C}$, whereas it remains constant in the case of CdSe-PMMA. A temperature…
A Design of Scintillator Tiles Read Out by Surface-Mounted SiPMs for a Future Hadron Calorimeter
2015
Precision calorimetry using highly granular sampling calorimeters is being developed based on the particle flow concept within the CALICE collaboration. One design option of a hadron calorimeter is based on silicon photomultipliers (SiPMs) to detect photons generated in plastic scintillator tiles. Driven by the need of automated mass assembly of around ten million channels stringently required by the high granularity, we developed a design of scintillator tiles directly coupled with surface-mounted SiPMs. A cavity is created in the center of the bottom surface of each tile to provide enough room for the whole SiPM package and to improve collection of the light produced by incident particles…
Characterization of the ESR response of alanine dosimeters to low-energy Cu-target X-tube photons
2017
Abstract This article describes Electron Spin Resonance (ESR) response measurements of Kodak BioMax alanine films exposed to low-energy X-rays from a Cu-target tube operating at 20 kV. Commercial alanine detectors were used to ensure maximum reproducibility of the results, while the choice of a film was due the low penetration of the soft X-rays. X-ray energy spectra and fluences were determined with an innovative digital semiconductor detector system. These data were used to quantify the irradiation of the alanine films in terms of absorbed dose to water. The alanine films were found to present a stable response, highly linear with dose. To our knowledge, these data have not been previousl…
SiPMs coated with TPB: coating protocol and characterization for NEXT
2012
[EN] Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless \bb decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs offer important advantages, mainly high gain, ruggedness, cost-effectiveness and radio-purity. Their main drawback, however, is their non sensitivity in the emission spectrum of the xenon scintillation (peak at 175 nm). This is overcome by coating these sensors with the organic wavelength shifte…
Extending the applicability of an open-ring trap to perform experiments with a single laser-cooled ion.
2015
An open-ring ion trap, also referred to as transparent trap was initially built up to perform $\beta$-$\nu$ correlation experiments with radioactive ions. This trap geometry is also well suited to perform experiments with laser-cooled ions, serving for the development of a new type of Penning trap, in the framework of the project TRAPSENSOR at the University of Granada. The goal of this project is to use a single $^{40}$Ca$^+$ ion as detector for single-ion mass spectrometry. Within this project and without any modification to the initial electrode configuration, it was possible to perform Doppler cooling on $^{40}$Ca$^+$ ions, starting from large clouds and reaching single ion sensitivity.…