Charge collection efficiency and resolution of an irradiated double-sided silicon microstrip detector operated at cryogenic temperatures

1999

Abstract This paper presents results on the measurement of the cluster shapes, resolution and charge collection efficiency of a double-sided silicon microstrip detector after irradiation with 24 GeV protons to a fluence of 3.5×10 14  p/cm 2 and operated at cryogenic temperatures. An empirical model is presented which describes the expected cluster shapes as a function of depletion depth, and is shown to agree with the data. It is observed that the clusters on the p-side broaden if the detector is under-depleted, leading to a degradation of resolution and efficiency. The model is used to make predictions for detector types envisaged for the LHC experiments. The results also show that at cryo…

PhysicsNuclear and High Energy PhysicsLarge Hadron ColliderPhysics::Instrumentation and Detectorsbusiness.industryResolution (electron density)DetectorBiasingFluenceOpticsCluster (physics)IrradiationDetectors and Experimental TechniquesbusinessInstrumentationDiodeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Performance Studies of Pixel Hybrid Photon Detectors for the LHCb RICH Counters

2006

The Pixel Hybrid Photon Detector is a vacuum tube with a multi-alkali photo cathode, high voltage cross-focused electron optics and an anode consisting of a silicon pixel detector bump-bonded to a readout CMOS electronic chip fully encapsulated in the device. The Pixel HPD fulfils the requirements of the Ring Imaging Cherenkov counters of the LHCb experiment at LHC. The performances of the Pixel HPD will be discussed with reference to laboratory measurements, Cherenkov light imaging in recent beam tests, image distortions due to a magnetic field.

PhysicsNuclear and High Energy PhysicsLarge Hadron ColliderPixelPhysics::Instrumentation and Detectorsbusiness.industryCherenkov detectorVacuum tubeHigh voltageAtomic and Molecular Physics and OpticsCathodelaw.inventionOpticslawComputer Science::Computer Vision and Pattern RecognitionElectron opticsOptoelectronicsbusinessCherenkov radiationNuclear Physics B - Proceedings Supplements
researchProduct

Characterisation and compensation of magnetic distortions for the pixel Hybrid Photon Detectors of the LHCb RICH

2005

Abstract The LHCb experiment at LHC, optimised for the study of CP violation, has two RICH detectors to provide particle identification in the momentum range ∼ 2 – 100 GeV / c . The stringent requirements on the photon detectors are met by the custom-made pixel Hybrid Photon Detector. The photon detectors need to operate in the fringe field of the LHCb dipole magnet which will produce distortions of the image detected on the pixel chip which is encapsulated inside the HPD. This paper reports on the experimental characterisation of the image distortions caused by an external magnetic flux density. These measurements allow for the development of a parameterisation of the effects and a compens…

PhysicsNuclear and High Energy PhysicsLarge Hadron ColliderPixelPhysics::Instrumentation and Detectorsbusiness.industryDetectorParticle identificationMagnetic fieldMomentumOpticsDipole magnetCP violationHigh Energy Physics::ExperimentbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

The new CERN-ISOLDE on-line mass-separator facility at the PS-Booster

1992

The ISOLDE on-line isotope separators have been operated since 1967 at the CERN-SC. This 600 MeV proton synchro-cyclotron had to be shut down in December 1990 after 33 years of service and it was decided to move ISOLDE to a new experimental area. The new on-line mass-separator facility is now under construction at the CERN PS-Booster. This accelerator provides an average current of about 2-mu-A of 1 GeV protons in very short high intensity pulses at low repetition rate. The beam can hit either one of the two target stations, the general purpose separator (GPS), a reconstructed ISOLDE-2 type machine (which can deliver beams simultaneously into three beam lines), and the high resolution separ…

PhysicsNuclear and High Energy PhysicsLarge Hadron ColliderProtonSeparator (oil production)ISOLTRAPIsotope separationlaw.inventionNuclear physicsBeamlineGeneral purposelawDetectors and Experimental TechniquesInstrumentationBeam (structure)Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Laser ion beam production at CERN-ISOLDE: New features – More possibilities

2016

Abstract This article summarizes the current specifications and the latest features of the CERN-ISOLDE resonance ionization laser ion source (RILIS). This includes a description of the optical layout and the newly designed reference system. The ionization schemes for the laser ionized beams at ISOLDE are tabulated, including six new elements. All RILIS schemes are also made publicly available in the RILIS elements on-line database. Finally, we announce a paradigm shift in RILIS operation – the combination of a machine protection and a monitoring and control system has enabled on-call operation of the laser ion source for selected beams in 2014 and has become the standard mode of operation i…

PhysicsNuclear and High Energy PhysicsLarge Hadron ColliderRILISIon beamResonance laser ionization010308 nuclear & particles physicsbusiness.industryLaser01 natural sciencesMonitoring and controlAccelerators and Storage RingsIon sourceISOLDElaw.inventionOpticslawIonization0103 physical sciencesResonance ionizationAtomic physics010306 general physicsbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Silicon detectors for forward tracking in ATLAS

1996

Abstract A 12 cm long silicon microstrip detector module with a fan geometry has been designed and constructed. The performance of the detector has been studied in a test beam at CERN. Results are presented on the hit efficiency and the position resolution as a function of position along the strips. With a hit efficiency of 99.5% and a spatial resolution of typically 35 μm the performance of these detectors exceeds that of other candidate technologies for the precision forward tracker of the ATLAS inner detector.

PhysicsNuclear and High Energy PhysicsLarge Hadron ColliderSiliconPhysics::Instrumentation and Detectorsbusiness.industryDetectorchemistry.chemical_elementSTRIPSTracking (particle physics)law.inventionmedicine.anatomical_structureOpticschemistryAtlas (anatomy)Position (vector)lawmedicineHigh Energy Physics::ExperimentDetectors and Experimental TechniquesbusinessInstrumentationImage resolution
researchProduct

Silicon microstrip detectors for the ATLAS SCT

2002

Abstract The ATLAS Semiconductor Tracker at the Large Hadron Collider (LHC) will incorporate ∼20,000 individual silicon microstrip sensors representing ∼60 m 2 of silicon. Production and delivery of the sensors is already underway and scheduled for completion by late 2002. The sensors have been optimised for operation in the harsh radiation environment of the LHC, and subjected to an extensive qualification program in which their pre- and post-irradiation characteristics have been evaluated. The sensor design features are reviewed, together with their electrical characteristics and the Quality Control procedures adopted by ATLAS during production.

PhysicsNuclear and High Energy PhysicsLarge Hadron ColliderSiliconbusiness.industryQuality controlchemistry.chemical_elementddc:500.2Linear particle acceleratorParticle detectorSemiconductor detectorNuclear physicsmedicine.anatomical_structureSemiconductorchemistryAtlas (anatomy)medicineElectronic engineeringIrradiationATLAS SCTbusinessInstrumentationSilicon microstrip detectorsSilicon microstrip detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

The Endcap Disc DIRC detector of PANDA

2019

Abstract At the international FAIR laboratory, an upcoming significant enlargement of the GSI installations near Darmstadt, Germany, the PANDA antiproton experiment will investigate fundamental questions of hadron physics in the charm quark energy range. Antiprotons in the 1.5 to15 GeV/c momentum range will interact with gas jet or pellet fixed targets. The Endcap Disc DIRC (Detection of Internally Reflected Cherenkov light) covers the forward endcap solid angle of the PANDA target spectrometer to positively identify charged kaons. Monte-Carlo simulations indicate that from 1 up to 4 GeV/c one can achieve kaon–pion separation with a separation power of at least 3 standard deviations. For th…

PhysicsNuclear and High Energy PhysicsLarge Hadron ColliderSpectrometerPhysics::Instrumentation and Detectors010308 nuclear & particles physicsDetectorJet (particle physics)01 natural sciences030218 nuclear medicine & medical imagingCharm quarkNuclear physicsMomentum03 medical and health sciences0302 clinical medicineDetection of internally reflected Cherenkov lightAntiproton0103 physical sciencesPhysics::Accelerator PhysicsHigh Energy Physics::ExperimentNuclear ExperimentInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

A $B_4C$-silicon target for the detection of neutrino interactions

1998

This note describes the construction of a target for neutrino interactions composed of passive boron carbide plates interleaved with silicon microstrip detectors. The target contains four layers of passive material with a total mass of 45 kg and 600 single--sided silicon microstrip detectors with a total surface of 1.14 m$^2$ distributed over five layers. It is installed in the NOMAD spectrometer at the CERN SPS neutrino beam. During the 1997 run about 8000 \nm\ charged current interactions were estimated to have occurred in the target. For these events it will be possible to perform a precise measurement of both vertex and kinematical variables. This will provide invaluable experience towa…

PhysicsNuclear and High Energy PhysicsLarge Hadron ColliderSpectrometerSiliconPhysics::Instrumentation and DetectorsFísicachemistry.chemical_elementsilicon microstrip detectors; neutrino oscillations; silicon strip sensors; tracking detectors; search; alignmentNuclear physicsNeutrino detectorchemistryMeasurements of neutrino speedHigh Energy Physics::ExperimentNeutrinoNeutrino oscillationInstrumentationCharged currentParticle Physics - Experiment
researchProduct

Alignment of the NOMAD-STAR detector

2000

Abstract This note describes the alignment of the NOMAD-STAR detector. This is the B 4 C-silicon target installed in the NOMAD spectrometer in 1997. NOMAD-STAR is composed of modules of 12 silicon detectors each giving a total length of 72 cm. Ten of these modules (called ladders) are assembled to form a layer. There are five layers interleaved with passive boron carbide plates. The total surface of silicon is 1.14 m 2 . Energetic muons from the flat-top of the CERN SPS cycle provide the necessary information to perform a very precise software alignment. This alignment is needed to ensure that the impact parameter measurement needed for the identification of taus in a detector like NOMAD-ST…

PhysicsNuclear and High Energy PhysicsLarge Hadron ColliderSpectrometerSiliconbusiness.industryDetectorchemistry.chemical_elementParticle detectorSemiconductor detectorOpticschemistryMeasuring instrumentbusinessInstrumentationSTAR detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct