Search results for "Instrumentation"
showing 10 items of 4914 documents
Improving the performance of CdZnTe detectors using infrared stimulation
2011
The influence of monochromatic optical stimulation with wavelengths from 400 nm to 1100 on characteristics of the CdZnTe quasi-hemispherical detectors was studied. It was found that illumination with infrared (IR) light of wavelengths (870–900 nm) close to the absorption edge of the CdZnTe significantly improves the detectors performance at room temperature. Improvement can be achieved with low-intensity IR illumination of about 1–10 µW. The higher intensity illumination leads to degradation of the detector spectrometric characteristics. Infrared radiation penetrates into the detector sensitive volume, change the balance equilibrium between free and trapped carriers, leading to improve char…
The optical instrumentation of the ATLAS Tile Calorimeter
2013
The purpose of this Note is to describe the optical assembly procedure called here Optical Instrumentation and the quality tests conducted on the assembled units. Altogether, 65 Barrel (or LB) modules were constructed - including one spare - together with 129 Extended Barrel (EB) modules (including one spare). The LB modules were mechanically assembled at JINR (Dubna, Russia) and transported to CERN, where the optical instrumentation was performed with personnel contributed by several Institutes. The modules composing one of the two Extended Barrels (known as EBA) were mechanically assembled in the USA, and instrumented in two US locations (ANL, U. of Michigan), while the modules of the oth…
A Very Large Area Telescope for γ-Ray Astronomy Above 100 MeV Employing Limited Streamer Tubes
1994
A new detector for γ-ray astronomy above 100 MeV is described in which the electron-positron pairs are tracked by means of a set of plane arrays of Limited Streamer Tubes. This technique allows to build up very large area experiments which are specifically useful to study variable or transient sources.
Evaluation of a Commercial PhotoDiode Array for Radiation Detectors Readout
2011
The aim of the present work is the characterization of the new S8866-128-02 PhotoDiode (PD) array from Hamamatsu Photonics. This work includes the implementation of a readout system as well as electronic noise estimation in PDs under several conditions varying integration times and clock frequencies.
Limits on diffuse fluxes of high energy extraterrestrial neutrinos with the AMANDA-B10 detector
2003
Data from the AMANDA-B10 detector taken during the austral winter of 1997 have been searched for a diffuse flux of high energy extraterrestrial muon-neutrinos, as predicted from, e.g., the sum of all active galaxies in the universe. This search yielded no excess events above those expected from the background atmospheric neutrinos, leading to upper limits on the extraterrestrial neutrino flux. For an assumed E^-2 spectrum, a 90% classical confidence level upper limit has been placed at a level E^2 Phi(E) = 8.4 x 10^-7 GeV cm^-2 s^-1 sr^-1 (for a predominant neutrino energy range 6-1000 TeV) which is the most restrictive bound placed by any neutrino detector. When specific predicted spectral…
The Pierre Auger Observatory: latest results and future perspectives
2018
The Pierre Auger Observatory is the largest ultrahigh-energy cosmic ray observatory in the world. The huge amount of high quality data collected since 2004 up to now led to great improvements in our knowledge of the ultra-energetic cosmic rays. The suppression of the cosmic-ray flux at highest energies was clearly established, and the extra-galactic origin of these particles was confirmed. On the other hand, measurements of the depth of shower maximum indicate a puzzling trend in the mass composition of cosmic rays at energy around the ankle up to the highest energy. The just started upgrade of the Observatory, dubbed AugerPrime, will improve the identification of the mass of primaries allo…
FRAM—The Robotic Telescope for the Monitoring of the Wavelength Dependence of the Extinction: Description of Hardware, Data Analysis, and Results
2010
FRAM-F/(Ph)otometric Robotic Atmospheric Monitor is one of the atmospheric monitoring instruments at the Pierre Auger Observatory in Argentina. FRAM is an optical telescope equipped with CCD cameras and photometer, and it automatically observes a set of selected standard stars. Primarily, FRAM observations are used to obtain the wavelength dependence of the light extinction. FRAM telescope is also able to observe secondary astronomical targets, and namely the detection of optical counterparts of gamma-ray bursts has already proven to be successful. Finally, a wide-field CCD camera of FRAM can be used for rapid monitoring of atmospheric conditions along the track of particularly interesting …
The aperture for UHE tau neutrinos of the Auger fluorescence detector using a Digital Elevation Map
2005
We perform a new study of the chances of the fluorescence detector (FD) at the Pierre Auger Observatory to detect the tau leptons produced by Earth-skimming ultra high energy tau neutrinos. We present a new and more detailed evaluation of the effective aperture of the FD that considers a reliable fiducial volume for the experimental set up. In addition, we take into account the real elevation profile of the area near Auger. We find a significant increase in the number of expected events with respect to the predictions of a previous semi-analytical determination, and our results show the enhancement effect for neutrino detection from the presence of the near mountains.
Neutrino searches at the Pierre Auger Observatory
2013
Abstract The surface detector array of the Pierre Auger Observatory is sensitive to ultra-high energy neutrinos in the cosmic radiation. Neutrinos can interact in the atmosphere close to ground (down-going) and, for tau neutrinos, through the Earth-skimming mechanism (up-going) where a tau lepton is produced in the Earth crust that can emerge and decay in the atmosphere. Both types of neutrino-induced events produce an inclined particle air shower that can be identified by the presence of a broad time structure of signals in the water-Cherenkov detectors. We discuss the neutrino identification criteria used and present the corresponding limits on the diffuse and point-like source fluxes.
A facility to validate photomultipliers for the upgrade of the Pierre Auger Observatory.
2020
The Pierre Auger Observatory is undergoing a major upgrade named AugerPrime with the primary aim to add sensitivity to the mass-composition discrimination of ultrahigh-energy cosmic rays. Two different photomultipliers will be added to each water-Cherenkov station of the surface detector of Observatory. To achieve the scientific goals of AugerPrime these photomultipliers have to ensure a linear response to input-light in a wide range. This paper describes a system developed for the validation of AugerPrime-photomultipliers.