Search results for "Instrumentation"
showing 10 items of 4914 documents
Towards an Experimental Determination of the Transition Strength Between the Ground States of $^{20}$F and $^{20}$Ne
2017
Electron capture on $^{20}$Ne is thought to play a crucial role in the final evolution of electron-degenerate ONe stellar cores. Recent calculations suggest that the capture process is dominated by the second-forbidden transition between the ground states of $^{20}$Ne and $^{20}$F, making an experimental determination of this transition strength highly desirable. To accomplish this task we are refurbishing an intermediate-image magnetic spectrometer capable of focusing 7 MeV electrons, and designing a scintillator detector surrounded by an active cosmic-ray veto shield, which will serve as an energy-dispersive device at the focal plane.
Limitation of the ECRIS performance by kinetic plasma instabilities (invited).
2016
Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropic electron velocity distribution. The instabilities are associated with strong microwave emission and periodic bursts of energetic electrons escaping the magnetic confinement. The instabilities explain the periodic ms-scale oscillation of the extracted beam current observed with several high performance ECRISs and restrict the parameter space available for the optimization of extracted beam currents of highly charged ions. Experiments with the JYFL 14 GHz ECRIS have demonstrated that due to the instabilities the optimum Bmin-field is less than 0.8BECR, which is the value suggested by …
Transverse distribution of beam current oscillations of a 14 GHz electron cyclotron resonance ion source
2014
The temporal stability of oxygen ion beams has been studied with the 14 GHz A-ECR at JYFL (University of Jyvaskyla, Department of Physics). A sector Faraday cup was employed to measure the distribution of the beam current oscillations across the beam profile. The spatial and temporal characteristics of two different oscillation “modes” often observed with the JYFL 14 GHz ECRIS are discussed. It was observed that the low frequency oscillations below 200 Hz are distributed almost uniformly. In the high frequency oscillation “mode,” with frequencies >300 Hz at the core of the beam, carrying most of the current, oscillates with smaller amplitude than the peripheral parts of the beam. The result…
Charged-current neutrino-nucleus scattering off Xe isotopes
2019
Xenon detectors are used in the search for dark matter and neutrinoless double-beta decay ($0\ensuremath{\nu}\ensuremath{\beta}\ensuremath{\beta})$. As the next-generation detectors reach masses in the ton scale, neutrinos from astrophysical sources are soon predicted to become background in such detectors. Theoretical predictions of neutrino scattering cross sections and information of nuclear structure effects therein are crucial in accounting for the background. We perform calculations for differential and total cross sections of charged-current neutrino scattering off the most abundant xenon isotopes. The nuclear-structure calculations are made in the proton-neutron quasiparticle random…
Limitations of electron cyclotron resonance ion source performances set by kinetic plasma instabilities.
2015
Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropy of the electron energy distribution function stemming from the resonant nature of the electron heating process. Electron cyclotron plasma instabilities are related to non-linear interaction between plasma waves and energetic electrons resulting to strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents observed in several laboratories. It is demonstrated with a minimum-B 14 GHz ECRIS operating on helium, oxygen, and argon plasmas that kinetic instabilities restrict the parameter space avail…
The on-board calibration system of the X-ray Imaging Polarimetry Explorer (XIPE)
2016
The calibration system for XIPE is aimed at providing a way to check and correct possible variations of performance of the Gas Pixel Detector during the three years of operation in orbit (plus two years of possible extended operation), while facilitating the observation of the celestial sources. This will be performed by using a filter wheel with a large heritage having a set of positions for the calibration and the observation systems. In particular, it will allow for correcting possible gain variation, for measuring the modulation factor using a polarized source, for removing non interesting bright sources in the field of view and for observing very bright celestial sources. The on-board …
A facility for fast-neutron irradiations at Jyväskylä and its use for nuclide cross-section measurements in fission
2013
Abstract An efficient and reliable transport system for fast-neutron irradiations has been built at the Physics Department, Jyvaskyla, Finland. It is constructed from commercial bicycle components and is driven by a computer-controlled stepping motor. It can be operated in single or cyclic mode. The neutron irradiated targets are moved within 1.2 s (full stop to full stop) to a well-shielded position 3 m away where they can be removed or directly investigated by γ spectroscopy. The system has been built with the aim to experimentally verify the calculated production rates of neutron-rich nuclei in the SPIRAL2 uranium target. However, the facility can be used for various kinds of fast-neutro…
Enhancement of Bremsstrahlung Radiation Generated by Electron Beam Interaction in an Axially-Oriented Scintillator Crystal (Poster)
2019
Since their discovery, scintillator materials have played an important role in nuclear and particle physics, as well as in medical and industrial imaging. [...]
Automated astrographic plates measuring process
1990
The astrographic plates measuring process applied at the Astronomical Observatory of Valencia has been described.
"Table 3" of "Measurement of azimuthal anisotropy of muons from charm and bottom hadrons in $pp$ collisions at $\sqrt{s}=13$ TeV with the ATLAS detec…
2020
Summary of results for charm and bottom muon v2 as a function of multiplicity. Uncertainties are statistical and systematic, respectively.