Search results for "Instrumentation"

showing 10 items of 4914 documents

Twin GEM-TPC prototype (HGB4) beam test at GSI and Jyväskylä : a development for the Super-FRS at FAIR

2017

The FAIR[1] facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI research institute. One major part of the facility will be the Super-FRS[2] separator, which will be include in phase one of the project construction. The NUSTAR experiments will benefit from the Super-FRS, which will deliver an unprecedented range of radioactive ion beams (RIB). These experiments will use beams of different energies and characteristics in three different branches; the high-energy which utilizes the RIB at relativistic energies 300-1500 MeV/u as created in the production process, the low-energy bra…

Radioactive ion beamsPhysics - Instrumentation and DetectorsPhysics::Instrumentation and DetectorsSeparator (oil production)hiukkaskiihdyttimet01 natural sciences7. Clean energy114 Physical sciencesParticle identificationNuclear physics0103 physical sciencesElectronicsNuclear ExperimentdetectorsPhysicsta114010308 nuclear & particles physicsProjectileI.2.7Detectorparticle acceleratorsilmaisimetAntiprotonPhysics::Accelerator PhysicsF.2.2Beam (structure)
researchProduct

The SPEDE Spectrometer: Combined In-Beam γ-ray and Conversion Electron Spectroscopy with Radioactive Ion Beams

2015

The SPEDE spectrometer [1] aims to combine a silicon detector, for the detection of electrons, with the MINIBALL γ-ray detection array for in-beam studies employing radioactive ion beams at the HIE-ISOLDE facility at CERN. The setup will be primarily used for octupole collectivity [2] and shape coexistence studies [3, 4] in Coulomb excitation experiments. In the shape coexistence cases the transitions between states of the same spin and parity have enhanced E0 strength [5]. Additionally the 0→0 transitions, typically present in nuclei exhibiting shape coexistence [6], can only occur via E0 transitions, i.e. via internal conversion electron emission.

Radioactive ion beamsPhysicsLarge Hadron ColliderSpectrometerta114Physics::Instrumentation and DetectorsParity (physics)Coulomb excitationElectronElectron spectroscopyPhysics::Accelerator PhysicsSilicon detectorAtomic physicsconversion electron spectrometersNuclear Experiment
researchProduct

Beam cooler for low-energy radioactive ions

2001

Abstract An ion beam cooler for mass-separated radioactive ion beams has been developed and tested at the IGISOL-type mass separator facility. Technical description and characteristic properties are presented. An energy spread below 1 eV and transmission efficiency of 60% were measured.

Radioactive ion beamsPhysicsNuclear and High Energy PhysicsIon beamSeparator (oil production)Ion gunIonIon beam depositionLow energyPhysics::Accelerator PhysicsAtomic physicsNuclear ExperimentInstrumentationBeam (structure)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

A sextupole ion beam guide to improve the efficiency and beam quality at IGISOL

2008

The laser ion source project at the IGISOL facility, Jyvaskyla, has motivated the development and construction of an rf sextupole ion beam guide (SPIG) to replace the original skimmer electrode. The SPIG has been tested both off-line and on-line in proton-induced fission, light-ion and heavy-ion induced fusion-evaporation reactions and, in each case, has been directly compared to the skimmer system. For both fission and light-ion induced fusion, the SPIG has improved the mass-separated ion yields by a factor of typically 4 to 8. Correspondingly, the transmission efficiency of both systems has been studied in simulations with and without space charge effects. The transport capacity of the SP…

Radioactive ion beamsPhysicsNuclear and High Energy PhysicsIon beambusiness.industryFOS: Physical sciencesOpticsPhysics::Plasma PhysicsLaser beam qualityNuclear Experiment (nucl-ex)businessNuclear ExperimentInstrumentationNuclear Experiment
researchProduct

Wavelet analysis and neural network classifiers to detect mid-sagittal sections for nuchal translucency measurement

2016

We propose a methodology to support the physician in the automatic identification of mid-sagittal sections of the fetus in ultrasound videos acquired during the first trimester of pregnancy. A good mid-sagittal section is a key requirement to make the correct measurement of nuchal translucency which is one of the main marker for screening of chromosomal defects such as trisomy 13, 18 and 21. NT measurement is beyond the scope of this article. The proposed methodology is mainly based on wavelet analysis and neural network classifiers to detect the jawbone and on radial symmetry analysis to detect the choroid plexus. Those steps allow to identify the frames which represent correct mid-sagitta…

Radiology Nuclear Medicine and ImagingAcoustics and UltrasonicsComputer scienceGeneral MathematicsMaterials Science (miscellaneous)Acoustics and UltrasonicWavelet analysi030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineWaveletNuchal translucencyNuchal Translucency MeasurementmedicineMathematics (all)Instrumentation1707lcsh:R5-920Mid-sagittal section030219 obstetrics & reproductive medicineArtificial neural networkSettore INF/01 - Informaticabusiness.industrylcsh:MathematicsUltrasoundPattern recognitionSymmetry transformlcsh:QA1-939Sagittal planeNeural networkIdentification (information)True negativemedicine.anatomical_structureNuchal translucencySignal ProcessingComputer Vision and Pattern RecognitionArtificial intelligencebusinesslcsh:Medicine (General)Biotechnology
researchProduct

Mechanically stable metal layers for ohmic and blocking contacts on CdZnTe detectors by electroless deposition

2015

CdZnTe detectors are commonly exploited for the detection of gamma rays. However, obtaining mechanical stable, low noise contacts on CdZnTe is still an issue. In particular, ohmic contacts would be preferable for high flux applications. In this work, we show that it is possible to obtain mechanical stable gold contacts by electroless deposition in methanol solution. Moreover, we show that electroless deposited nickel contacts are also mechanical stable and are good candidates for the realization of ohmic contacts on high resistivity CdZnTe crystals.

Radiology Nuclear Medicine and ImagingMaterials scienceContactschemistry.chemical_elementElectroless depositionCrystalsMetalNickelOhmic contactAnodesInstrumentationNuclear and High Energy Physicbusiness.industryBlocking (radio)MethanolMetallurgyDetectorSettore FIS/01 - Fisica SperimentaleDetectorsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)AnodeLow noiseNickelchemistryvisual_artvisual_art.visual_art_mediumOptoelectronicsGoldbusiness
researchProduct

Charge carrier transport mechanisms in CdZnTe detectors grown by the vertical Bridgman technique

2016

In this work, we report on the results of electrical characterization of CdZnTe (CZT) detectors, with gold electroless contacts, grown by the boron oxide encapsulated vertical Bridgman technique (B-VB), currently produced at IMEM-CNR (Parma, Italy). The detectors, with different thicknesses (1 and 2.5 mm), have the same electrode layout: the anode is a central electrode (2 x 2 mm(2)) surrounded by a guard ring electrode. The cathode is a planar electrode covering the detector surface (4.1 x 4.1 mm(2)). Current-voltage (I-V) characteristics were measured at different temperatures in order to study the charge transport and the electrical properties. These detectors were compared with the trav…

Radiology Nuclear Medicine and ImagingMaterials sciencebusiness.industryDetectorSettore FIS/01 - Fisica SperimentaleBiasingCathodePhoton countingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Anodelaw.inventionDetectors; Crystals; Conductivity; Temperature measurement; Leakage currents; Surface treatment; TemperaturelawElectrodeOptoelectronicsCharge carrierbusinessInstrumentationVoltageNuclear and High Energy Physic
researchProduct

Digital CZT detector system for high flux energy-resolved X-ray imaging

2017

Photon counting arrays with energy resolving capabilities are recently desired for the next-generation X-ray imaging systems. In this work, we present the performance of a 2 mm thick CZT pixel detector, with pixel pitches of 500 mu m and 250 mu m, coupled to a fast and low noise ASIC (PIXIE ASIC), characterized by only the preamplifier stage. A 16-channel digital readout electronics was used to continuously digitize and process each output channel from the PIXIE ASIC, performing multi-parameter analysis (event arrival time, pulse shape, pulse height) at low and high input counting rates (ICRs). The spectroscopic response of the system to monochromatic X-ray and gamma ray sources, at both lo…

Radiology Nuclear Medicine and ImagingPhysics::Instrumentation and DetectorsPreamplifier01 natural sciences030218 nuclear medicine & medical imagingCharge sharing03 medical and health sciences0302 clinical medicineOptics0103 physical sciencesInstrumentationNuclear and High Energy PhysicPhysicsPixel010308 nuclear & particles physicsbusiness.industryDetectorSettore FIS/01 - Fisica SperimentaleGamma raySMALL PIXEL; CDTE; PERFORMANCE; RESOLUTION; PROGRESS; CTPhoton countingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Electronic Optical and Magnetic MaterialsPixieMonochromatic colorbusiness
researchProduct

Emissitivity spectra obtained from field and laboratory measurements using the temperature and emissivity separation algorithm.

2006

Surface emissivities play an important role in thermal remote sensing, since knowledge of them is required to estimate land surface temperature with enough accuracy. They are also important in other environmental or geological studies. We show the results obtained for the emissivity spectra of different natural surfaces (water, green, and senescent vegetation) by applying the temperature and emissivity separation (TES) algorithm to ground-based measurements collected at the field with a multiband thermal radiometer. The results have been tested with data included in spectral libraries, and rms errors lower than 0.01 have been found, except for senescent vegetation. Two methods are also prop…

RadiometerMaterials scienceMaterials Science (miscellaneous)InstrumentationMultispectral imageThermalEmissivityRadiative transferBusiness and International ManagementTemperature measurementIndustrial and Manufacturing EngineeringSpectral lineRemote sensingApplied optics
researchProduct

Correlation of radioactivity measurements, air kerma rates and geological features of Sicily

2006

Abstract Sicily, the largest Mediterranean island (with an extension of about 25 000 km 2 ), exhibits a very wide variety of lithologies, ranging from sedimentary to metamorphic and volcanic rocks. Principal component analysis (PCA) and hierarchical cluster analysis (HCA) have been applied to air kerma values measured by thermoluminescent dosimetry in several sites and to data of radionuclide concentrations, geochemical and mineralogical features of rocks and soils sampled in 29 sites of Sicily to point out similarities among different lithologies. The study was devoted to find multiple correlations and allow a better classification of Sicilian lithotypes. Samples of rocks and soils have be…

Radionuclidegeographyeducation.field_of_studyRadiationgeography.geographical_feature_categorySoil testLithologyPopulationMineralogyNatural radioactivity Sicily Elemental concentration Mineralogy Environmental doseVolcanic rockPetrographyKermaSedimentary rockeducationInstrumentationGeologyRadiation Measurements
researchProduct