Search results for "Insulation"
showing 10 items of 61 documents
Partial Discharge Detection Using a Spherical Electromagnetic Sensor
2019
The presence of a partial discharge phenomenon in an electrical apparatus is a warning signal that could determine the failure of the insulation system, terminating the service of the apparatus and/or the network. In this paper, an innovative partial discharge (PD) measurement instrument based on an antenna sensor is presented and analyzed. Being non-intrusive is one of the most relevant features of the sensor. The frequency response of the antenna sensor and the features to recognize different PD sources and automatically synchronize them with the supply voltage are described and discussed in details. The results show the performance of the instrument can make a fast and correct diagnosis …
High-Speed Machines: Typologies, Standards, and Operation under PWM Supply
2018
This paper presents an overview of the most recent state of the art in the field of high-speed electric machines fed through high-frequency converters. This type of systems is rapidly wide spreading in aeronautical and automotive applications, as well as microturbines. Each typology has its own advantages and downsides, which are analytically presented in this paper. Some types of high-speed electric machines require high-frequency voltage supply, highly stressing the dielectric materials of the winding insulation system. For this reason, in high-speed electric drives, premature failure may occur and a reduction of the total system reliability has been observed in the past years. Such issue…
Evaluation of innovative thermal insulation systems for a sustainable envelope
2017
La memoria presenta i risultati ottenuti su sistemi di isolamento termico per l’involucro edilizio. Si presentano i risultati ottenuti tramite simulazioni informatiche che hanno consentito di verificare e ottimizzare la trasmissione del calore attraverso un sistema sottovuoto in vetro per le facciate trasparenti. Inoltre la possibilità offerta dal riciclo del materiale di scarto della potatura dell’Opunthia Ficus Indica (fichi d’india) che,opportunamente trattato ha permesso di ottenere un materiale isolante (Brevetto n. 1402131), in forma di pannello o in grani sfusi, (valori di coibenza termica 0.0710.057 W/mK). The paper presents the results of the research on thermal insulation systems…
SiC-based sandwich material for Flow Channel Inserts in DCLL blankets: Manufacturing, characterization, corrosion tests
2017
This work has been carried out within the framework of the EUROfusion Consortium and has received funding from the Euratom research and training programme 2014–2018 under grant agreement No 633053. The views and opinions expressed herein do not necessarily reflect those of the European Commission.
Influence on PD Parameters due to Voltage Conducted Disturbances
2004
In the standard specification of ac dielectric-characteristic measurements of insulating materials, test voltage is prescribed as "approximately sinusoidal" when the highest acceptable deviation of the HV waveform, from the correct sinusoidal shape, is limited to a /spl plusmn/5% tolerance range of the crest factor value. In the field of partial discharge (PD) measurements and their statistical data processing, on which forecasts of long term behavior of components and their reliability are currently carried out, the results of elaborations depend on the voltage wave shape. In this paper, the errors in PD measurements, evaluated at industrial frequencies, due to applied voltages distorted b…
From Wood and Hemp Biomass Wastes to Sustainable Nanocellulose Foams
2021
Abstract Transition to the circular economy requires the implementation of recycling and reuse routes for waste products. This research addresses one of the leading emerging areas, i.e., the development of sustainable materials and natural waste processing, namely wood and hemp byproducts. The cellulosic nanomaterials derived from these under-utilized waste residues and byproducts also serve as promising natural precursors for advanced applications, e.g., biomedical, pollution filtering, and thermal insulation. The wood and hemp fibrils were prepared by microfluidic processing of 0.2 – 1.0 wt% cellulose water suspensions. After freeze-drying, the resulting foam materials were characterized …
Estimation of the effective diffusivity of blowing agents in closed-cell low-density polyurethane foams based on thermal aging data
2021
Abstract Low-density closed-cell polyurethane (PU) foams are applied as thermal insulation materials due to their low thermal conductivity imparted by that of the physical blowing agent (PBA) used in foam production. However, foam conductivity tends to gradually increase with time, primarily due to changes in the gas composition in foam cells brought about by gas diffusion. To enable predicting the variation of conductivity during the service life of foam insulation, gas diffusivities are usually determined by measuring the gas composition in foams at different aging times. This study considers an alternative approach of estimating the effective diffusivities of gases in PU foams, which is …
Wireless partial discharge tracking on cross-linked polyethylene MV and HV cables
2018
Medium voltage (MV)/high voltage (HV) cable lines are high-value assets and require substantial costs for their installation or replacement. For this reason, the capability to assess the condition of cable lengths and accessories on site is of great importance. Cross-linked polyethylene (XLPE) insulation is extensively used for MV, HV, and extra-high voltage (EHV) class cables [1] thanks to its excellent voltage-endurance and thermomechanical properties. In particular, XLPE-insulated cables feature substantially lower losses, easier manufacturing and jointing procedures, better environmental compatibility, and higher operating temperature compared with impregnated paper cables, which lead t…
Influence of the rainfall measurement interval on the erosivity determinations in the Mediterranean area
2006
Summary The single-storm erosion index, EI, of the USLE and RUSLE models may vary appreciably with the rainfall measurement interval, Δ t . However, the effect of Δ t on EI has not been investigated in the Mediterranean area. Approximately 700 erosive events and 1.5 years of rainfall energies measured by a rainfall impact measurement device were used to evaluate the effect of the rainfall measurement interval (5 min ⩽ Δ t ⩽ 60 min) on the erosivity determinations in the Mediterranean semi-arid area of Sicily. According to both literature and practical considerations, a reference time interval equal to 15 min was used in this investigation. Hourly rainfall data led to an appreciable underes…
Evaluation and application of Opuntia ficus-indica insulation panel
2015
Today the attention to the building sustainability issue is increasingly important, because of the major responsibility of the buildings field in the environmental degradation: both in terms of energy consumption from non-renewable sources and the raw materials impoverishment. In addition, the level of comfort required by users are growing and the thermal insulation of buildings becomes the key element in the reduction of energy consumption and C02 emissions, both in the case of new construction and existing ones. The thermal insulation of buildings is the key element in the reduction of energy consumption and C02 emissions due to the cooling of building interiors, both in the case of new c…