Search results for "Integra"
showing 10 items of 5314 documents
Enhancement in the computation of gradient retention times in liquid chromatography using root-finding methods.
2019
Abstract Gradient elution may provide adequate separations within acceptably short times in a single run, by gradually increasing the elution speed. Similarly to isocratic elution, chromatograms can be predicted under any experimental condition, through strategies based on retention models. The most usual approach implies solving an integral equation (i.e., the fundamental equation of gradient elution), which has an analytical solution only for certain combinations of retention model and gradient programme. This limitation can be overcome by using numerical integration, which is a universal approach although at the cost of longer computation times. In this work, several alternatives to impr…
Experimental determination of mode I fracture parameters in orthotropic materials by means of Digital Image Correlation
2020
Abstract The mode I fracture parameters for an orthotropic body are directly calculated from full-field deformation measurements provided by Digital Image Correlation (DIC). Three complementary and direct approaches are evaluated and compared: (i) the determination of the Stress Intensity Factor (SIF) by fitting the displacement field using the analytical expression proposed by Lekhnitskii; (ii) the determination of the J-Integral by using the Energy Domain Integral (EDI) formulation on the raw DIC data; and (iii) the calculation of the J-Integral using the EDI approach on the displacement data fitted using Lekhnitskii’s formulation. A comparative experimental study is performed by testing …
Process intensification in a photocatalytic membrane reactor: Analysis of the techniques to integrate reaction and separation
2017
Abstract Different methods to integrate reaction and separation in a membrane reactor are studied in the present work, with the aim being to highlight the pros and cons of the different alternatives and the effects of the intervening parameters. The coupling of the two processes can take place inside a single apparatus or using separate units. If a single apparatus is utilized, the coupling is more direct, but separate units offer higher degrees of freedom for the design with more opportunities to optimize the system without constraints. However, when using separate units, the integration of the two unit operations depends largely on the parameters intervening in the coupling procedure. The…
Critical Influence of Dielectric Sensitive Material and Manufactured Process in Microwave Gas-Sensing: Application of Ammonia Detection with an Inter…
2020
In this paper, authors propose a study on microwave gas sensors and the influence of critical key parameters such as the sensitive material and the circuit conception process. This work aims to determine the influence of these parameters on the quality of the final response of the microwave gas sensor. The fixed geometry of the sensor is a microstrip interdigital capacitor coated with a sensitive layer excited with two 50 Ω SMA ports. The sensitive material has been chosen in order to interact with the target gas: ammonia. Indeed, this gas interacts with phthalocyanine and metal oxides like hematite, TiO2. To explore the effect of the circuit manufacturing process, three series of samples a…
Evaluating Thermal Corrections for Adsorption Processes at the Metal/Gas Interface
2019
International audience; Adsorption and desorption steps are key for active catalysts and rely on a subtle balance between enthalpic and entropic terms. While the enthalpic term is becoming ever more accurate through density functional development, the entropic term remains underrated and its precise determination a great challenge. In this work, we have performed extensive first principles thermodynamic integration (TI) simulations for the 1 adsorption of small (e.g., CO) to larger (e.g., phenol) molecules at metallic surfaces and compared their adsorption free energies to the values obtained by vertical, static statistical mechanics approximations to thermal corrections invoking three diff…
Ontology-Based Information System
2014
We describe a novel way for creating information systems based on ontologies. The described solution is aimed at domain experts who would benefit from being able to quickly prototype fully-functional, web-based information system for data input, editing and analysis. The systems backbone is SPARQL 1.1 endpoint that enables organization users to view and edit the data, while outside users can get read-only access to the endpoint. The system prototype is implemented and successfully tested with Latvian medical data ontology with 60 classes and imported 5 000 000 data-level triples.
Wronskian representation of solutions of NLS equation, and seventh order rogue wave.
2012
This work is a continuation of a recent paper in which we have constructed a multi-parametric family of the nonlinear Schrodinger equation in terms of wronskians. When we perform a special passage to the limit, we get a family of quasi-rational solutions expressed as a ratio of two determinants. We have already construct Peregrine breathers of orders N=4, 5, 6 in preceding works; we give here the Peregrine breather of order seven.
The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase
2023
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (i…
The IXO Wide-Field Imager
2010
The Wide Field Imager (WFI) of the International X-ray Observatory (IXO) is an X-ray imaging spectrometer based on a large monolithic DePFET (Depleted P-channel Field Effect Transistor) Active Pixel Sensor. Filling an area of 10 × 10 cm² with a format of 1024 × 1024 pixels it will cover a field of view of 18 arcmin. The pixel size of 100 × 100 μm² corresponds to a fivefold oversampling of the telescope's expected 5 arcsec point spread function. The WFI's basic DePFET structure combines the functionalities of sensor and integrated amplifier with nearly Fano-limited energy resolution and high efficiency from 100 eV to 15 keV. The development of dedicated control and amplifier ASICs allows for…
The wide-field imager for IXO: status and future activities
2010
The Wide Field Imager (WFI) of the International X-ray Observatory (IXO) is an X-ray imaging spectrometer based on a large monolithic DePFET (Depleted P-channel Field Effect Transistor) Active Pixel Sensor. Filling an area of 10 x 10 cm2 with a format of 1024 x 1024 pixels it will cover a field of view of 18 arcmin. The pixel size of 100 x 100 μm2 corresponds to a fivefold oversampling of the telescope's expected 5 arcsec point spread function. The WFI's basic DePFET structure combines the functionalities of sensor and integrated amplifier with nearly Fano-limited energy resolution and high efficiency from 100 eV to 15 keV. The development of dedicated control and amplifier ASICs allows for…