On the effects of HV/MV stations on global grounding systems
2016
The METERGLOB project has faced the issue of the identification of Global Grounding Systems. One of the main point of the problem is to define if an interconnection of single grounding systems gives place to a Global Grounding System in any condition and for every kind of ground fault. This paper focuses the attention on what happens in the case of single line to ground fault inside a HV/MV station whose ground electrode is connected to the cable' shields of the MV lines outgoing the station and supplying the secondary substations of a given area.
Stability Analysis and Stabilization of T-S Fuzzy Delta Operator Systems with Time-Varying Delay via an Input-Output Approach
2013
Published version of an article in the journal: Mathematical Problems in Engineering. Also available from the publisher at: http://dx.doi.org/10.1155/2013/913234 Open Access The stability analysis and stabilization of Takagi-Sugeno (T-S) fuzzy delta operator systems with time-varying delay are investigated via an input-output approach. A model transformation method is employed to approximate the time-varying delay. The original system is transformed into a feedback interconnection form which has a forward subsystem with constant delays and a feedback one with uncertainties. By applying the scaled small gain (SSG) theorem to deal with this new system, and based on a Lyapunov Krasovskii funct…
Robust stability and stabilization of uncertain T-S fuzzy systems with time-varying delay: An input-output approach
2013
An input-output approach to the stability and stabilization of uncertain Takagi-Sugeno (T-S) fuzzy systems with time-varying delay is proposed in this paper. The time-varying parameter uncertainties are assumed to be norm-bounded, and the delay is intervally time varying. A novel method is employed to approximate the time-varying delay, based on which the considered system is transformed into a feedback interconnection form. The new formulation of the system is comprised of a forward subsystem with constant time delay and a feedback subsystem embedding the uncertainties. By applying the scaled small-gain theorem to the converted system, less conservative stability and stabilization criteria…
A refractive free-space microoptical 4 x 4 interconnect on chip level with optical fan-out fabricated by the LIGA technique
2002
A parallel purely refractive 4/spl times/4 optical data link has been built. The design is based on pairs of crossed cylindrical microlenses. The optical module is fabricated and monolithically integrated in. polymethyl methacrylate (PMMA) by the LIGA technique.
2020
The growth of cloud-based services is mainly supported by the core networking infrastructures of large-scale data centers, while the scalability of these services is influenced by the performance and dependability characteristics of data centers. Hence, the data center network must be agile and reconfigurable in order to respond quickly to the ever-changing application demands and service requirements. The network must also be able to interconnect the big number of nodes, and provide an efficient and fault-tolerant routing service to upper-layer applications. In response to these challenges, the research community began exploring novel interconnect topologies, namely: Flecube, DCell, Ficonn…
Interconnections criteria of grounding grids in global grounding systems
2018
A Global Grounding System is defined as the combination of local grounding systems, obtained by their interconnection, which ensures, thanks to their proximity, that no dangerous touch voltages can arise. The interconnection of grounding systems via the armors of the MV cables, between secondary substations and HV/MV stations is herein analyzed to verify the effects on touch voltages in ground-fault conditions. In particular, two main issues are discussed: 1) the transfer of dangerous voltages to secondary substations, due to ground-faults occurring at the HV/MV station; 2) the reduction in the magnitude of the ground potential rise due to ground-fault conditions at secondary substations, t…
Integration Issues of Distributed Generators Considering Faults in Electrical Distribution Networks
2014
In the recent years there is a great interest in integration of distributed generation (DG) units at distribution level; this integration leads to planning as well as operational challenges. Some possibilities to handle grid planning issues are addressed in this paper. Effects on grid protection, fault current level, and voltage profile are investigated and described for different types of DG units; the classification of DG units is based on their terminal characteristics in terms of real and reactive power delivering capability. Different scenarios for mis-coordination problems caused by DG interconnection are discussed. The effect of the DG on the voltage profile of a distribution network…
Risk indexes for studying interconnected earthing systems inside MV networks
2006
The paper presents a risk-evaluation-based approach to the issue of interconnection between the earth electrodes of the MV/LV substations within MV networks. After a short introduction on the interconnection between earthing systems, the paper proposes four risk indexes defined starting from the safety requirements given by CENELEC HD 63 7 S1. The indexes allow one to put in evidence, in a clear way, the benefits of the interconnection in terms of reduction of risk of critical electric shock for persons and of stress on the insulation of the LV devices in the presence of single line to earth faults and double earth faults inside MV/LV substations and single line to earth faults inside HV/MV…
Evaluation of the power quality from a seawave power farm for different interconnection schemes
2007
In this paper we present an approach to the interconnection of a seawave power farm to the grid The generator type used in the farm is a Permanent Magnet (PM) linear generator driven from the seawaves that generates, therefore, highly distorted emfs. We propose and compare two possible ways to interconnect the farm to the grid. One is based on an approach where for each generator there is a conversion subsystem that permits the direct connection of each generator to the a.c. network, the other one is based on an ac.-d.c. converter that is connected to the generator, the converter is connected to a dc link that can receive the power from every unit and that can supply a dc-ac converter direc…
Analysis of interconnection substations for sewave power farms
2014
In this paper we analyse the interconnection of a seawave power farm to the grid. The generator type used in the farm is a linear synchronous generator driven from the seawaves that generates, highly distorted emfs. We presents two possible ways to interconnect the farm to the grid. One is based on an approach where for each generator there is a conversion subsystem that permits the direct connection of each generator to the a.c. network, the other one is based on an a.c.-d.c. converter that is connected to the generator, the converter is connected to a dc link that can receive the power from every unit and that can supply a dc-ac converter directly connected to the main.