Search results for "Interferometer"
showing 10 items of 109 documents
GW170817: Implications for the Stochastic Gravitational-Wave Background from Compact Binary Coalescences
2018
The LIGO Scientific and Virgo Collaborations have announced the first detection of gravitational waves from the coalescence of two neutron stars. The merger rate of binary neutron stars estimated from this event suggests that distant, unresolvable binary neutron stars create a significant astrophysical stochastic gravitational-wave background. The binary neutron star background will add to the background from binary black holes, increasing the amplitude of the total astrophysical background relative to previous expectations. In the Advanced LIGO-Virgo frequency band most sensitive to stochastic backgrounds (near 25 Hz), we predict a total astrophysical background with amplitude $\Omega_{\rm…
Effect of Static Disorder in an Electron-Fabry Perot Interferometr with Two Quantum Scattering Centers
2007
In a recent paper -- F. Ciccarello \emph{et al.}, New J. Phys. \textbf{8}, 214 (2006) -- we have demonstrated that the electron transmission properties of a one-dimensional (1D) wire with two identical embedded spin-1/2 impurities can be significantly affected by entanglement between the spins of the scattering centers. Such effect is of particular interest in the control of transmission of quantum information in nanostructures and can be used as a detection scheme of maximally entangled states of two localized spins. In this letter, we relax the constraint that the two magnetic impurities are equal and investigate how the main results presented in the above paper are affected by a static d…
Active Plasmonics in True Data Traffic Applications: Thermo-Optic On/Off Gating Using a Silicon-Plasmonic Asymmetric MachZehnder Interferometer
2012
We present the first system-level demonstration of an active plasmonic device in 10-Gb/s data traffic conditions. An asymmetric silicon-plasmonic Mach-Zehnder interferometer with dielectric-loaded plasmonic waveguides serving as the electrically controlled arms, operates as thermo-optic ON/OFF gating element with 2.8-mu s response time and 10.8-mW power consumption. We present the first system-level demonstration of an active plasmonic device in 10-Gb/s data traffic conditions. An asymmetric silicon-plasmonic Mach-Zehnder interferometer with dielectric-loaded plasmonic waveguides serving as the electrically controlled arms, operates as thermo-optic ON/OFF gating element with 2.8-mu s respon…
Infrared laser threshold magnetometry with a NV doped diamond intracavity etalon
2019
International audience; We propose a hybrid laser system consisting of a semiconductor external cavity laser associated to an intra-cavity diamond etalon doped with nitrogen-vacancy color centers. We consider laser emission tuned to the infrared absorption line that is enhanced under the magnetic field dependent nitrogen-vacancy electron spin resonance and show that this architecture leads to a compact solid-state magnetometer that can be operated at room-temperature. The sensitivity to the magnetic field limited by the photon shot-noise of the output laser beam is estimated to be less than 1 pT/ √ Hz. Unlike usual NV center infrared magnetometry, this method would not require an external f…
Space-borne Bose–Einstein condensation for precision interferometry
2018
Space offers virtually unlimited free-fall in gravity. Bose-Einstein condensation (BEC) enables ineffable low kinetic energies corresponding to pico- or even femtokelvins. The combination of both features makes atom interferometers with unprecedented sensitivity for inertial forces possible and opens a new era for quantum gas experiments. On January 23, 2017, we created Bose-Einstein condensates in space on the sounding rocket mission MAIUS-1 and conducted 110 experiments central to matter-wave interferometry. In particular, we have explored laser cooling and trapping in the presence of large accelerations as experienced during launch, and have studied the evolution, manipulation and interf…
Gravitational-wave Detection and Parameter Estimation for Accreting Black-hole Binaries and Their Electromagnetic Counterpart
2020
We study the impact of gas accretion on the orbital evolution of black-hole binaries initially at large separation in the band of the planned Laser Interferometer Space Antenna (LISA). We focus on two sources: (i)~stellar-origin black-hole binaries~(SOBHBs) that can migrate from the LISA band to the band of ground-based gravitational-wave observatories within weeks/months; and (ii) intermediate-mass black-hole binaries~(IMBHBs) in the LISA band only. Because of the large number of observable gravitational-wave cycles, the phase evolution of these systems needs to be modeled to great accuracy to avoid biasing the estimation of the source parameters. Accretion affects the gravitational-wave p…
Resilience of singlet-state extraction against non-optimal resonance conditions
2008
We have recently presented a protocol for extracting the singlet state of two non-interacting high-dimensional spins through post-selection of the internal state of interaction mediators sent in succession [F. Ciccarello et al., arXiv:0710.3855v1]. The scheme requires each mediator's wavevector to obey appropriate resonance conditions. Here we show the robustness of the scheme in the realistic case where such conditions are not sharply fulfilled.
Evaluation of performance of a hybrid electro-optic directional coupler and a Mach–Zehnder switch
2017
The efficiency of an electro-optic (EO) directional coupler (DC) and a Mach–Zehnder (MZ) switch is discussed. The specific designs employ a passive waveguide core and an EO cladding. The performance of a DC switch was evaluated by numerical methods, namely coupled mode theory (CMT), eigenmode expansion (EME) method, and beam envelope method. Using the CMT and EME methods, it is shown that in the DC with a passive waveguide core and EO cladding at certain waveguide parameters the switching effect does not take place. The effect is demonstrated for the first time and suggests that careful optimization of the DC switch should be done before experimental realization of the device. The efficienc…
Miniature MOEMS hyperspectral imager with versatile analysis tools
2019
The Fabry-Perot interferometers (FPI) are essential components of many hyperspectral imagers (HSI). While the Piezo-FPI (PFPI) are still very relevant in low volume, high performance applications, the tunable MOEMS FPI (MFPI) technology enables volume-scalable manufacturing, thus having potential to be a major game changer with the advantages of low costs and miniaturization. However, before a FPI can be utilized, it must be integrated with matching optical assembly, driving electronics and imaging sensor. Most importantly, the whole HSI system must be calibrated to account for wide variety of unwanted physical and environmental effects, that significantly influence quality of hyperspectral…
First M87 Event Horizon Telescope Results. II. Array and Instrumentation
2019
The Event Horizon Telescope (EHT) is a very long baseline interferometry (VLBI) array that comprises millimeter- and submillimeter-wavelength telescopes separated by distances comparable to the diameter of the Earth. At a nominal operating wavelength of ~1.3 mm, EHT angular resolution (λ/D) is ~25 μas, which is sufficient to resolve nearby supermassive black hole candidates on spatial and temporal scales that correspond to their event horizons. With this capability, the EHT scientific goals are to probe general relativistic effects in the strong-field regime and to study accretion and relativistic jet formation near the black hole boundary. In this Letter we describe the system design of th…