Search results for "Interrupt"
showing 10 items of 61 documents
Reconfiguration: a key to handle exceptions and performance deteriorations in manufacturing operations
2005
During a manufacturing operation, exceptions may occur dynamically and unpredictably. Their occurrence may lead to the degradation of system performance or, in the worst case scenario may interrupt the production process by causing errors in the schedule plan. This paper classifies three families of exceptions: (1) out-of-order events such as machine breakdowns, (2) operational out-of-ordinary events such as rush orders and (3) deteriorations of manufacturing resource performance such as reductions of machines' utilization. In all cases, in order to maintain an adequate level of system performance, it is necessary to detect exceptions, to diagnose them quickly and to recover them by taking …
Robust model-following control of parallel UPS single-phase inverters
2008
This paper presents a robust control technique applied to modular uninterruptible power-supply (UPS) inverters operating in parallel. When compared to conventional proportional-integral (PI) control, the proposed technique improves the response of the output voltage to load steps and to high distorted output currents, reducing the distortion of the output voltage. Furthermore, an excellent distribution of currents between modules is achieved, resulting in fine power equalization between the inverters on stream. The crossover frequency of the different loop gains involved is moderate, so that robustness to variations of the operation point and to modeling uncertainties is achieved. A compara…
Circuit Breakers – a legal analysis of volatility safeguards in the rules of stock exchanges on the occasion of the COVID-19 crisis
2020
Abstract This paper examines circuit breakers (CBs), i. e. emergency systems of trading venues that interrupt or restrain trading when significant price movements of financial instruments occur. After a description of the ratio legis and the economic fundamentals, the genesis and the different forms of CBs are presented. The European legal framework is then outlined. The relevant rules of the Frankfurt Stock Exchange (FWB) serve as an example.
Series arc faults in AC and DC electrical circuits. Characterization and detection methods
2013
This paper analyzes the problem of the arc faults in both AC and DC low voltage electrical circuits. The state-of-the-art of the arc fault detection methods is analyzed together with the UL 1699 and UL 1699B Standard requirements for protection devices against arc faults (AFCIs). An experimental characterization is carried out of the arc fault phenomenon, for both AC and DC systems, focusing the attention on series arcs. The experimental measurements are carried out on a proper test bench, which has been developed in order to reproduce significant arcing conditions, in accordance with the UL 1699 Standard requirements.
Déclaration et vérification des créances. Instance en cours interrompue et conditions de la reprise d'instance
2017
International audience; (Com. 27 sept. 2016, n° 14-24.107, arrêt n° 787 F-D, Sté Fonderies Collignon c/ Mme Annie G. et a.)
Effectiveness of Safety Warnings in Atypical Antipsychotic Drugs
2009
Studies conducted to obtain drug authorization are often of short duration and based on small sample sizes in selected populations. Policies on drug safety rely on the validity of the methods used to achieve rapid and effective communication of new information. No formal evaluation has ever been made of the Spanish communications system, although indirect data have raised questions about its effectiveness.To evaluate the impact of two safety warnings issued by the Spanish Drug Agency, and of a later prior authorization requirement involving the use of atypical antipsychotic drugs in the elderly.The study was based on a time-series analysis constructed with data corresponding to monthly invo…
Flow barriers : What prevents software developers from experiencing flow in their work
2022
Software development requires high problem-solving skills and creativity, making it a profession with good opportunities to become immersed in a flow experience. The characteristics of flow experience are absorption, enjoyment, and intrinsic motivation toward the activity. This study aims to better understand the barriers that prevent software developers from experiencing flow at work. Previous research has mostly examined software developers’ productivity, flow being one component of productive workdays. This study addresses the research gap by exploring the barriers to experiencing flow in software development. A qualitative questionnaire was used to gather data about flow experiences fro…
A case report of pulmonary vein isolation performed in a patient with polysplenia and interrupted inferior vena cava
2021
Abstract Background Pulmonary vein isolation (PVI) has entrenched itself as one of the main approaches for the treatment of paroxysmal symptomatic atrial fibrillation (AF). Pulmonary vein isolation prevents focal triggers from pulmonary veins from initiating AF paroxysms. As standard—PVI is performed through the inferior vena cava (IVC) approach, through the femoral vein. However, there are conditions when this approach is not appropriate or is not available. Case summary We report a case of a 53-year-old male who was referred to Pauls Stradins Clinical University Hospital for PVI due to worsening AF. Due to the rare anatomical variant of the venous system, the standard approach to PVI coul…
Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis
2017
This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard…
Effect of a distal weight-bearing implant on visual analog scale scores in 23 transfemoral amputees.
2018
The objective of this interrupted time series clinical trial was to evaluate the effect of a distal weight-bearing implant on well-being in patients with transfemoral amputations using the visual analog scale (VAS). A total of 29 patients from five hospitals with previous transfemoral amputations were surgically implanted with an osseoanchored implant with a distal spacer that allows a direct load on the residuum over the distal surface of the socket. Patients were followed for a 14-month period and assessed presurgically and postsurgically using the VAS. The Wilcoxon test was used to evaluate the differences between variables. VAS mean scores improved significantly after intervention. Sign…