Search results for "Interventional radiology"
showing 10 items of 182 documents
Forty-slice MDCT enteroclysis: evaluation after oral administration of isotonic solution in Crohn's disease.
2007
Objective. The aim of this study was to evaluate the accuracy of multidetector computed tomography (MDCT) enteroclysis after oral hyperhydration with isotonic solution in detecting bowel wall alterations in patients with Crohn’s disease. Materials and methods. Twenty-eight patients with a diagnosis of Crohn’s disease established by ileocolonoscopy and histology were enrolled in the study; 15 patients with negative ileocolonoscopy served as controls. In all cases, MDCT enteroclysis was performed after oral administration of 2,000 ml of isotonic solution and intravenous administration of N-butylscopolamine. Axial, isotropic multiplanar and volume-rendered reconstructions were used to evaluate…
Stent-assisted detachable coil embolization of wide-necked renal artery aneurysms
2017
Renal artery aneurysms (RAAs) are rare with an estimated incidence of 0.1% in the general population, and they represent approximately 25% of all visceral aneurysms. The gold standard of treatment is open surgery, but it is associated with a high risk of nephrectomy, mortality, and morbidity. Less invasive endovascular therapies are becoming increasingly common for the treatment of RAAs. Here, we aimed to report three cases of wide-necked complex renal artery aneurysms treated endovascularly using stent-assisted coil embolization with self-expandable stent nitinol Solitaire AB and Concerto Axium coils. In addition, we describe the use of the waffle-cone technique in a case of wide-necked sa…
Characterisation of indeterminate focal breast lesions on grey-scale ultrasound: role of ultrasound elastography.
2011
PURPOSE: This study was undertaken to evaluate the role of ultrasound (US) elastography in characterising focal breast lesions classified as indeterminate on B-mode US. MATERIALS AND METHODS: Eighty-four focal breast lesions, 64 benign and 20 malignant (mean diameter, 15.1 mm), detected but not characterised on B-mode US in 72 women, Breast Imaging Reporting and Data System (BI-RADS) US category 3 (n=56) or category 4 (n=28), were studied with US elastography and classified in consensus by two radiologists according to a five-point colour scale. Sensitivity, specificity and positive and negative predictive values (PPV and NPV) of US elastography compared with conventional US were calculated…
CT exposure in adult and paediatric patients: a review of the mechanisms of damage, relative dose and consequent possible risks.
2014
An increase has been observed not only in the absolute number of CT examinations but also in the length of coverage and number of scanning phases, with the result that exposure to ionising radiation from CT is becoming an increasingly serious problem. The extent of the problem is not entirely known and cannot be adequately addressed without proper knowledge of all the phases that leads to the effective dose calculation. In light of the growing awareness of the issue of ionising radiation dose and the possible risk for the individual and the population, there is a need for radiologists, medical physicists and radiographers to play an active role in dose management. In this review, the author…
Treatment of isolated ascending aortic aneurysm by off-pump epiaortic wrapping is safe and durable.
2016
OBJECTIVES: Isolated ascending aortic aneurysm (iAA) is usually treated by open graft repair requiring sternotomy, cardiopulmonary bypass (CPB) and cardioplegia. This approach carries significant mortality in older patients or those presenting with comorbidities. We report an original series of patients presenting with iAA and treated with epiaortic wrapping by using a synthetic mesh. This less invasive aortic repair technique allows reducing the aortic diameter to a predefined value and is performed without CPB. METHODS: Data from patients presenting with an iAA and treated with the wrapping technique (WT) by polypropylene/polyester mesh from November 2006 to July 2015 were collected. The …
TAVI imaging: over the echocardiography
2020
Aortic valve stenosis (AS) is a common valvular heart disease. Recently, transcatheter aortic valve implantation (TAVI) has changed the treatment of severe AS in elderly patients with contraindications to traditional surgical replacement. Echocardiography is conventionally used as the first imaging modality to assess the presence and severity of AS and to provide anatomical and functional information. Nowadays, imaging techniques play a crucial role in the planning of TAVI to define suitable candidates. Computed tomography (CT) is essential to display the anatomy of the aortic valve complex (including aortic annulus, Valsalva sinuses, coronary arteries ostia, sinotubular junction), thoracoa…
Integrated non-invasive approach to atherosclerosis with cardiac CT and carotid ultrasound in patients with suspected coronary artery disease
2017
The aim of the study was to compare the atherosclerotic disease in the coronary and carotid arteries in patients who underwent non-invasive imaging for suspected stable coronary artery disease (CAD). 107 patients (64 men, age 59 ± 12) with atypical chest pain underwent cardiac CT (CCT) and carotid ultrasound (US) on the same day. Severity (obstructive or not-obstructive disease), location, shape, and composition of atherosclerotic plaques in the two districts were evaluated. Patients presented normal coronary arteries in 36 % (n = 38), not-obstructive CAD in 36 % (n = 39), and obstructive CAD in 28 % (n = 30), while had normal carotid arteries in 53 % (n = 57), not-obstructive disease in 44…
Umbilical venous catheters placement evaluation on frontal radiogram: application of a simplified flow-chart for radiology residents
2017
Background: Umbilical Venous Catheter (UVC) are commonly used in neonatal period; they can be not correctly positioned and could be associated with complications. The purpose of this article is to suggest a flow-chart to evaluate the placement of UVC, testing it in young radiologists-in-training. Method: We developed a simple flow-chart to asses, steps by step, UVC placement considering its course and tip location (ideally placed in the atriocaval junction). We tested the flow-chart impact asking to 20 residents to evaluate the placement of 10 UVC before and after they familiarized with the flow-chart and the anatomical findings of a newborn. The agreement among the 20 students was evaluate…
Darstellung des Blutflusses in den Gebärmutterarterien und im normalen sowie malignen Gebärmuttergewebe mittels einer 2D-Multiphasen-Tagging-Technik
1998
PURPOSE The aim of this pilot study was to evaluate a 2D-STAR technique as a non contrast-enhanced approach to demonstrate the uterine artery and its branches and to assess the cervical uterine blood flow in healthy volunteers and in patients with advanced uterine cervical carcinoma. MATERIALS AND METHODS Seven healthy volunteers (mean age, 29 years) and twenty-two patients (mean age, 52 years) with advanced cancer of the uterine cervix (FIGO IIB-IVA) were prospectively examined by 2D-STAR imaging at different inversion delay times (300 ms-1900 ms) which showed the passage of a blood bolus through normal and malignant tissue of the uterine cervix. RESULTS The uterine artery was well visuali…
ERCP and MRCP--when and why.
2002
Since the introduction of endoscopic retrograde cholangiopancreatography (ERCP) in the 1970s, gastroenterologists have a wide spectrum of diagnostic and therapeutic options in the biliopancreatic ductal system at their disposal. With its arrival in the 1990s, magnetic resonance cholangiopancreatography (MRCP) developed as a potent diagnostic tool in biliopancreatic pathology. Currently, MRCP is widely replacing diagnostic ERCP and thereby avoiding complications related to endoscopic technique.We summarize evidence-based data and demonstrate indications and differential indications for MRCP and ERCP in pancreatic disease. Complications related to the procedures and possible medical preventio…