Cinical outcomes of Endurant II stent-graft for infrarenal aortic aneurysm repair: comparison of on-label versus off-label use.
2016
Purpose We aimed to compare the outcomes of the Endurant II (Medtronic) stent-graft used under instructions for use versus off-label in high-risk patients considered unfit for conventional surgery. Methods Data from patients treated with the Endurant II stent-graft between December 2012 and March 2015 were retrospectively analyzed. Sixty-four patients were included. Patients were assigned to group A if treated under instructions for use (n=34, 53%) and to group B if treated off-label (n=30, 47%). Outcome measures included perioperative mortality and morbidity, survival, freedom from reintervention, endoleak incidence, in-hospital length of stay, and mean stent-graft component used. Mean fol…
Diagnostic accuracy of 64-slice computed tomography coronary angiography in patients with low-to-intermediate risk
2007
Purpose. Our aim was to evaluate the diagnostic accuracy of 64- slice computed tomography coronary angiography (MSCT-CA) for detecting significant stenosis (≥50% lumen reduction) in a population of patients at low to intermediate risk. Materials and methods. We studied 72 patients (38 men, 34 women, mean age 53.9±8.0 years) with atypical or typical chest pain and stratified in the low- to intermediate risk category. MSCT-CA (Sensation 64 Cardiac, Siemens, Germany) was performed after IV administration of 100 ml of iodinated contrast material (Iomeprol 400 mgI/ml, Bracco, Italy). Two observers, blinded to the results of conventional coronary angiography (CAG), assessed the MSCT-CA scans in c…
Transgastric imaging-The key to successful periprocedural TEE guiding for edge-to-edge repair of the tricuspid valve.
2021
Intraprocedural transesophageal echocardiography (TEE) guidance plays an essential role in transcatheter repair therapy of the tricuspid valve (TV). So far, several different imaging concepts are in use. We propose an imaging protocol that fully addresses the morphological complexity of the TV and further offers efficacious workarounds for the frequently occurring restrictions of TV imaging in edge-to-edge repair of the TV. As a tertiary referral center with a large experience of more than 250 cases of transcatheter edge-to-edge repair (TEER) of the TV performed at the Heart Valve Center in Mainz/Germany, we have constantly adapted our peri-interventional echocardiographic approach to accom…
Current Concepts and Perspectives on Brain Arteriovenous Malformations: A Review of Pathogenesis and Multidisciplinary Treatment.
2021
Brain arteriovenous malformations (bAVMs) are unusual vascular pathologies characterized by the abnormal aggregation of dilated arteries and veins in the brain parenchyma and for which the absence of a normal vascular structure and capillary bed leads to direct connections between arteries and veins. Although bAVMs have long been believed to be congenital anomalies that develop during the prenatal period, current studies show that inflammation is associated with AVM genesis, growth, and rupture. Interventional treatment options include microsurgery, stereotactic radiosurgery, and endovascular embolization, and management often comprises a multidisciplinary combination of these modalities. T…
Radiation exposure in vascular angiographic procedures.
2012
Abstract Purpose To evaluate dose reduction in vascular angiographic procedures by using fluoroscopy capture instead of digital subtraction angiography frames for documentation. Materials and Methods A total of 764 consecutive vascular interventional procedures performed over a period of 1 year were retrospectively analyzed with respect to the fluoroscopy time and the resulting dose–area product (DAP), the DAP of the radiographic frames, and the overall DAP. Results A total of 70% of the total DAP was a result of the acquisition of radiographic frames, leaving only 30% being applied by fluoroscopy. Conclusions Fluoroscopy capture should be used for documentation whenever possible. A registr…
RADIOPROTECTION IN 2018: AN UPDATE
2018
Fluoroscopically-guided interventional procedures are performed in large numbers in Europe and in the United States. Radiation doses received by interventional radiologists can vary for the same type of procedure and for similar patient doses. Occupational radiation protection is a necessity whenever radiation is used in the practice of medicine. The International Commission on Radiological Protection is engaging against occupational radiation damages, publishing regular recommendations on dose limits. These limits are expressed as effective doses for the whole body and also as equivalent doses for particular regions or tissues of practitioners’ bodies. Shielding and personal protective clo…
Ultrasound-guided lumbar puncture for nusinersen administration in spinal muscular atrophy patients.
2020
Background and purpose The purpose was to report the results of ultrasound-guided lumbar puncture for the administration of nusinersen in spinal muscular atrophy (SMA) patients with complex spines. Methods Eighteen SMA patients (five children, five adolescents and eight adults) with either severe scoliosis or spondylodesis were evaluated for ultrasound-guided lumbar puncture. Ultrasound was performed with a 3.5 MHz transducer to guide a 22 gauge × 15 mm needle, which was placed in the posterior lumbar space following a parasagittal interlaminar approach. Results Twelve patients had undergone spinal instrumentation (nine growing rods and three spinal fusion) whilst the other six showed sever…
Final Evaluation Of a Prospective, Non-Interventional Study On Efficacy and Tolerability Of a New Generation VWF/FVIII Concentrate In The Treatment O…
2013
Background With marketing authorization in 2005, a non-interventional study (SET = Surveillance of Efficacy and Tolerability) with a double virus inactivated VWF/FVIII concentrate (Wilate®) was initiated in Germany. In 2012, the inclusion of patient documentation was terminated for final evaluation of the study data, representing the treatment of 170 patients suffering from von Willebrand’s disease (VWD). Aim The presented study was performed to assess the haemostatic efficacy and safety of a newly introduced VWF/FVIII product in the treatment of all types of VWD patients in every day clinical setting and to validate the results from pivotal clinical trials. Methods Patients of any age suf…
Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European Asso…
2018
This Consensus Document is the first of two reports summarizing the views of an expert panel organized by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) on the clinical use of intracoronary imaging including intravascular ultrasound (IVUS) and optical coherence tomography (OCT). The first document appraises the role of intracoronary imaging to guide percutaneous coronary interventions (PCIs) in clinical practice. Current evidence regarding the impact of intracoronary imaging guidance on cardiovascular outcomes is summarized, and patients or lesions most likely to derive clinical benefit from an imaging-guided intervention are identified. The relevance of the u…
Structured reporting of rectal cancer staging and restaging: A consensus proposal
2021
Background: Structured reporting (SR) in oncologic imaging is becoming necessary and has recently been recognized by major scientific societies. The aim of this study was to build MRI-based structured reports for rectal cancer (RC) staging and restaging in order to provide clinicians all critical tumor information. Materials and Methods: A panel of radiologist experts in abdominal imaging, called the members of the Italian Society of Medical and Interventional Radiology, was established. The modified Delphi process was used to build the SR and to assess the level of agreement in all sections. The Cronbach’s alpha (Cα) correlation coefficient was used to assess the internal consistency of ea…