Search results for "Intraocular Lenses"
showing 10 items of 70 documents
Tolerance to rotation of toric monofocal and bifocal intraocular lenses. A theoretical study
2018
Abstract This manuscript aims to evaluate the tolerance to rotation of a toric monofocal and a toric bifocal intraocular lenses with different cylinder powers. Theoretical designs based on wavefront aberrations were created to simulate a toric monofocal and a toric bifocal intraocular lens. Cylinder power ranged from −1 D to −6 D, in steps of −1 D. Tolerance to rotation was estimated by the visual Strehl ratio based on the optical transfer function (VSOTF) metric. Tolerance to rotation for both monofocal and bifocal intraocular lenses decreased when the cylinder power increased. For the bifocal design studied, the tolerance to rotation was larger for the near focus than for the far, however…
Effect of the color of the intraocular lens on optical and visual quality
2014
Purpose: To analyze the optical quality of intraocular lenses (IOL) with an orange (PC440Y) and a yellow (SN60AT) filter, and correlate these results with the visual quality of patients with these implants. Setting: Fisabio Oftalmología Médica, Valencia, Spain. Design: Randomized prospective study. Materials and Methods: The IOL optical quality was determined using the modulation transfer function (MTF) and the spectral transmission. The visual quality of 87 eyes with cataract (51 with orange filter and 36 with yellow filter) was determined by best corrected visual acuity (BCVA) and contrast sensitivity function (CSF) under photopic and mesopic conditions. To analyze the results, we use a S…
Physicochemical Surface Properties of Various Intraocular Lenses
2001
<i>Purpose:</i> It is of major interest to understand how intraocular lens (IOL) surfaces interact with aqueous humor or tissues after implantation. Important parameters to describe the physicochemical surface properties are the contact angle and critical surface tension. Therefore, we performed measurements of the contact angle and critical surface tension of several commercially available IOLs. <i>Setting:</i> Department of Ophthalmology, Johannes Gutenberg University, Mainz, University Eye Hospital, Tübingen, and Max Planck Institute for Polymer Research, Mainz, Germany. <i>Methods:</i> A total of 17 commercially available standard quality IOL types (6…
Schematic eye models to mimic the behavior of the accommodating human eye
2018
A simplified version of the human eye is known as schematic eye model. Since the first attempts in the middle of the 19th century, numerous approaches describing new schematic eye models have been introduced. Some of them are able to describe the accommodation ability of the human eye. Accommodative schematic eyes could be of great interest since they are able to explain the functionality of the human eye and they can be easily used for different research purposes. Some of these include the design and testing of multifocal ophthalmic solutions, evaluation of the effect of optical aberrations on the retinal image quality, and study of the optical performance of the eye at different distances…
Validation of a spectral light scattering method to differentiate large from small particles in intraocular lenses
2017
A psychophysical approach has been designed to measure straylight from intraocular lenses (IOLs) in vitro. This approach uses a clinical straylight meter (C-Quant) and an observer's eye as optical detector. Based on this, we introduced a method for study of straylight-wavelength dependency for IOLs. This dependency can be used to distinguish between 2 types of scattering particles (small and large) as defined by Mie theory. Validation was performed using a turbidity standard and scattering filters. Several IOLs were analyzed to identify potential scattering sources. Large particles were found to predominate in scattering from the studied lenses. This was confirmed by straylight-angular depe…
Modulation transfer function in refractive-diffractive multifocal intraocular lenses in vitro
2007
Purpose: The optical quality of two types of multifocal, hybrid refractive-diffractive, intraocular lenses (IOL) is analyzed in vitro. Following the EN-ISO international standard, the IOLs’ modulation transfer functions (MTF) are determined for both distance and near vision. The behaviour of these curves when the pupil size varies is studied. Methods: The IOLs analyzed were: AcrySoft ResTor SN60D3 (Alcon) and Tecnis ZM900 (AMO). The MTF was calculated from the cross line-spread function recorded with the OPAL Vector System (Image Science Ltd. Oxford) by using fast Fourier transform techniques. The artificial eye model used simulates in vivo conditions of the anterior chamber including an ar…
Optical quality of intraocular lenses after several years in the human eye
2013
The optical quality of explanted intraocular lenses (IOLs) was analysed to verify if their quality is maintained after having been in the human eye for several years. Twenty-five explanted IOLs were studied, 10 because of intraocular luxation and 15 from corneal donors. The dioptric power and modulation transfer function (MTF) were determined to discover the image quality of the IOLs. The spectral transmission was also established to ascertain whether the filter against ultraviolet (UV) radiation was still effective. The results show that the MTF of implanted IOLs is maintained and therefore so is the image quality they provide. Only decay in the MTF of some of the explanted IOLs was observ…
Aspheric intraocular lenses enhance contrast sensitivity
2007
Evaluation of: Pandita D, Raj SM, Vasavada VA, Vasavada VA, Kazi NS, Vasavada AR. Contrast sensitivity and glare disability after implantation of AcrySof IQ natural aspherical intraocular lens: pro...
Validity of automated refraction after segmented refractive multifocal intraocular lens implantation
2017
Aim To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Methods Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Results Ana…
Optical quality of hyperopic and myopic phakic intraocular lenses
2013
Aims: To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Settings and Design: Prospective study. Material and Methods: The wavefront aberrations of two myopic (−3 and −6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro . To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were ca…