Search results for "Inverter"

showing 10 items of 129 documents

Impact of wind speed on ventilation performance within a container installed with photovoltaic inverter

2017

Abstract PV inverter needs proper ventilation for reducing the heat dissipation of the electronic components. In this work, a container installed with PV inverter is considered with different configurations of cooling channels within the container for ventilation analysis. Typically, high capacity PV inverters are installed inside the container and therefore inverters, are not experiencing external wind effects and it depends on the configuration of cooling channels. In this work, the main cooling channel is located at the top of the inverter; inlet and outlet ventilation holes are located on the side of cross ventilation. They help in analyzing the cooling design, dependent on site specifi…

EngineeringRenewable Energy Sustainability and the EnvironmentTurbulencebusiness.industry020209 energyAirflowElectrical engineering02 engineering and technologyCooling flowComputational fluid dynamicsWind speedlaw.inventionMechanical fanlawVentilation (architecture)0202 electrical engineering electronic engineering information engineeringInverterbusinessMarine engineeringRenewable Energy
researchProduct

A simple and accurate model of photovoltaic modules for power system design

2014

EngineeringSIMPLE (military communications protocol)business.industryPhotovoltaic systemphotovoltaic arraysolar energyElectrical engineeringSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciPower system designMaximum power point trackingSolar micro-invertermodeling and simulationElectronic engineeringGrid-connected photovoltaic power systemrenewable energy sourcebusinessRooftop photovoltaic power station2014 Ninth International Conference on Ecological Vehicles and Renewable Energies (EVER)
researchProduct

Design issues for wind farms grid tied Inverter

2017

In this paper the Authors give indications for the design of a grid tied Voltage Source Inverters (VSI) aimed to optimal use in energy conversion from wind source. In particular, the design of the inverter is more focused on the control system planning, with a particular glance on the grid synchronization problem. After the exposition of general issues concerning renewable energies and associated topics, the case of a grid tied inverter is considered and a methodology of design is sketched starting from the consideration of the DC side and also considering the power device losses, the protection issue against over voltages and over-currents, snubber circuits, heat sinks and, finally the con…

EngineeringSustainability and the Environmentbusiness.industry020209 energy020208 electrical & electronic engineeringElectrical engineering02 engineering and technologySettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciGridwind farms inverter design control systemPower (physics)Renewable energyRenewable Energy Sustainability and the Environment; Automotive Engineering; Electrical and Electronic EngineeringSettore ING-IND/33 - Sistemi Elettrici per L'EnergiaControl systemAutomotive Engineering0202 electrical engineering electronic engineering information engineeringElectronic engineeringSnubberEnergy transformationInverterRenewable EnergyVoltage sourceElectrical and Electronic Engineeringbusiness2017 Twelfth International Conference on Ecological Vehicles and Renewable Energies (EVER)
researchProduct

A parametric study on unbalanced three phase islanded microgrids with inverter interfaced units

2013

In this paper, the solution of the power flow for unbalanced three phase microgrids systems is proposed. The study aims at the integration of inverter interfaced units using the control law used for primary voltage and frequency regulation, so as to take into account possible small variations of these parameters to account for sudden load changes. The proposed study deals with unbalanced systems which is the typical case of small distribution systems and shows how the power losses term varies as the regulators parameters vary as well, thus showing that these are sensitive parameters that could have an important role in optimal management of such systems.

EngineeringThree phaseIslanded power flowbusiness.industryUnbalanced systemsAutomatic frequency controlControl engineeringunbalanced systemsPower factorPower (physics)Settore ING-IND/33 - Sistemi Elettrici Per L'EnergiamicrogridThree-phaseControl theoryInverterthree phaseMicrogridsbusinessParametric statisticsVoltagePower control
researchProduct

Design of a grid connected inverter for sustainable small wind farms

2016

The actual definition of sustainability is nowadays widely accepted. It provides a very general indication on what it is, but it reveals unable to assert how it should be reached. However, if one considers the multiplicity of human activities that have led to talk of real process of human settlement on the environment, it is then understood how it is close to the particular mankind activities. Then the task of providing a guidance on what to do within the sustainability concept is delegated case by case. In this paper, with reference to wind renewable source, The Authors give some indications in the design of a voltage source inverters aimed to optimal use of the wind source. In particular …

EngineeringWind powerbusiness.industryProcess (engineering)Renewable Energy Sustainability and the Environment020209 energy020208 electrical & electronic engineeringEnergy Engineering and Power TechnologyControl engineering02 engineering and technologySettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciTask (project management)Renewable energyComputer Networks and CommunicationRisk analysis (engineering)Hardware and ArchitectureControl systemSustainability0202 electrical engineering electronic engineering information engineeringInverterVoltage sourcebusiness
researchProduct

Experimental test on a fuel cell powered brushless synchronous motor for automotive applications

2014

In this paper, a fuel cell powered motor emulator is proposed. The MATLAB/Simulink model including the fuel cell stack, the motor and drive models is described. The Urban Driving Cycle test is performed in MATLAB environment. Effective operating conditions of the whole fuel cell powered motor are accurately emulated according to actual regulations in force. The emulated current profile is used for experimental tests on a 5kW Nuvera PowerFlow stack. Thanks to the proposed approach, the motor and inverter drives are accurately emulated and the provided test-bench is used to evaluate performances of the stack under test for automotive applications. Simulation and experimental results are compa…

Engineeringbusiness.industryAutomotive industryautomotive fuel cell synchronous motor electric vehicles.Settore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciAutomotive engineeringStack (abstract data type)InverterFuel cellsbusinessMATLABSynchronous motorcomputerDriving cyclecomputer.programming_language3rd Renewable Power Generation Conference (RPG 2014)
researchProduct

DC link voltage swinging and load current unbalance in fault tolerant VSI. overview and compensation strategies

2015

The topic of this paper is the discussion on the performance of a three-phase fault tolerant inverter with particular attention to the underrated aspect of current unbalances occurring due to the DC link voltage fluctuates after the inverter reconfiguration. Capacitor voltage unbalance affects not only the average output voltage of the inverter, but also its performance. In fact, the inverter performance depends on the fluctuating DC-link voltage components rather than on the average DC-link voltage. After a brief analysis of the voltage fluctuation phenomena resulting from fault tolerant configuration and their effect on load current unbalance, the Authors consider different compensating p…

Engineeringbusiness.industryControl reconfigurationFault toleranceTopology (electrical circuits)Hardware_PERFORMANCEANDRELIABILITYPower converterSettore ING-IND/32 - Convertitori Macchine E Azionamenti Elettricilaw.inventionCompensation (engineering)Fault-toleranceCapacitorControl theorylawPower electronicsHardware_INTEGRATEDCIRCUITSInverterInverterCurrent (fluid)AC motor drivebusinessVoltage2015 AEIT International Annual Conference (AEIT)
researchProduct

Reducing DC Link Voltage Unbalance in a Fault-Tolerant Inverter

2014

Today, continuous working of power inverter drives is mandatory for several applications. Damages to materials, machines or even risks to human life have to be absolutely avoided. In the literature, fault-tolerant algorithms and architectures to achieve a successful fault handling are investigated. Researchers aim at reducing the number and cost of additional components, improving at the same time the inverter performances under postfault conditions. Cost, post-fault power derating and increasing distortion are usually conflicting requirements. In this paper, a fault-tolerant three phase inverter is presented. A reconfigurable architecture and a novel fault-tolerant algorithm is designed to…

Engineeringbusiness.industryDc link voltageFault current limiterElectronic engineeringInverterFault toleranceSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettricibusinessPower electronics Power converters AC motor drives fault-tolerant Inverter
researchProduct

A review of multiple faults diagnosis methods in Voltage Source Inverters

2015

This paper examines, as in short review, the methods of diagnosis of simple and multiple faults on Voltage Source Inverter (VSI). The methods examined here are essentially based on the inspection of the load currents. Some of these diagnosis methods are characterized by low computational effort, other for a better reliability avoiding faultless positive tests. Some solutions are characterized by a share of these benefits while others prefer an enforcement of trustworthiness, in spite of the lower calculation amount. The analysis of the technical literature, certainly, offers a glimpse about the creation of new algorithms and significant advances for the future.

Engineeringbusiness.industryFault toleranceSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciFault (power engineering)A shareFault indicatorReliability engineeringStuck-at faultReliability (semiconductor)Software fault toleranceVoltage sourcebusinessMultiple faultDiagnosiVoltage Source Inverters
researchProduct

Numerical Analysis of Medium Scale PV Plants and Their Power-Flow Control System With a Simple Three Phase Inverter

2012

This paper presents a mathematical analysis of a medium scale Photovoltaic (PV) power generation system connected to the distribution network and of its control system, in which the conversion stage is unique thanks to the absence of a boost chopper. Boost choppers are usually used as actuator for maximum power point tracking (MPPT). The conducted analysis leads to the conclusion that the used inverter presents two degrees of freedom that can be easily exploited in a control system in which the inverter simultaneously realizes the interconnection to the grid and at the same time realizes the MPPT control. The structure of the control system is then presented, discussed and then validated by…

Engineeringbusiness.industryPhotovoltaic systemPower factorPower Electronics PWM invertersSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciMaximum power point trackingPower optimizerMPPT controlElectric power systemStand-alone power systemControl theoryElectronic engineeringGrid-connected photovoltaic power systemPower-flow studybusinessPhotovoltaic system
researchProduct