Search results for "Ion beam"

showing 7 items of 297 documents

The relationship between visible light emission and species fraction of the hydrogen ion beams extracted from 2.45 GHz microwave discharge.

2015

The relationship between Balmer-α and Fulcher-band emissions with extracted H + , H + 2 , and H + 3 ions is demonstrated for a 2.45 GHz microwave discharge. Ion mass spectra and optical measurements of Balmer-α and Fulcher-band emissions have been obtained with a Wien Filter having an optical viewport on the plasma chamber axis. The beam of approximately 1 mA is analyzed for different plasma conditions simultaneously with the measurement of light emissions both with temporal resolution. The use of visible light emissions as a valuable diagnostic tool for monitoring the species fraction of the extracted beams is proposed. peerReviewed

plasma sourcesMaterials scienceWien filterta114Astrophysics::High Energy Astrophysical Phenomenaelektrodition beamsAstrophysics::Cosmology and Extragalactic AstrophysicsPlasmaelectrodesIonion sourcesPhysics::Plasma PhysicsTemporal resolutionMass spectrumPlasma diagnosticsAtomic physicsInstrumentationvisible lightAstrophysics::Galaxy AstrophysicsMicrowaveVisible spectrumThe Review of scientific instruments
researchProduct

A GEM-TPC in twin configuration for the Super-FRS tracking of heavy ions at FAIR

2018

The GEM-TPC [1] described herein will be part of the standard beam-diagnostics equipment of the Super-FRS [2] . This chamber will provide tracking information for particle identification at rates up to 1 MHz on an event-by-event basis. The key requirements of operation for these chambers are: close to 100% tracking efficiency under conditions of high counting rate, spatial resolution below 1 mm and a superb large dynamic range covering projectiles from Z=1 up to Z=92. The current prototype consists of two GEM-TPCs inside a single vessel, which are operating independently and have electrical drift fields in opposite directions. The twin configuration is done by flipping one of the GEM-TPCs o…

radioactive ion beamNuclear and High Energy PhysicsProtonfragment separatorPhysics::Instrumentation and Detectorssuper-FRSchemistry.chemical_elementTracking (particle physics)01 natural sciences7. Clean energyParticle identificationGSIXenonOptics0103 physical sciencesseurantaNuclear Experiment010306 general physicsInstrumentationImage resolutionPhysicsTime projection chamberta114010308 nuclear & particles physicsProjectilebusiness.industrytrackingfairtime projection chamberbeam adjustmentchemistrygas electron multiplierGas electron multiplierbusinessNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Transport and extraction of radioactive ions stopped in superfluid helium

2003

A new approach to convert a high energy beam to a low energy one, which is essential for the next generation radioactive ion beam facilities, has been proposed and tested at Jyvaskyla, Finland. An open Ra-223 alpha-decay-recoil source has been used to produce radioactive ions in superfluid helium. The alpha spectra demonstrate that the recoiling Rn-219 ions have been extracted out of liquid helium. This first observation of the extraction of heavy positive ions across the superfluid helium surface was possible thanks to the high sensitivity of radioactivity detection. An efficiency of 36% was obtained for the ion extraction out of liquid helium. (C) 2003 Elsevier Science B.V. All rights res…

radioactive ion beamNuclear and High Energy PhysicssnowballIon beamChemistryLiquid heliumExtraction (chemistry)superfluid heliumIGISOL TECHNIQUENUCLEAR-SPIN POLARIZATIONSpectral linelaw.inventionIonHelium-4lawPhysics::Accelerator PhysicsPhysics::Atomic PhysicsAtomic physicsNuclear ExperimentInstrumentationBeam (structure)Superfluid helium-4
researchProduct

Use of fragmentation beams at LNS with CHIMERA detector

2012

The recent intensity upgrade of the LNS fragmentation beam is discussed. The available beams, the tagging procedures and details on the beam quality are reported. The experimental program started with the CHIMERA detector using such beams is also discussed with preliminary results and future perspectives. © Owned by the authors, 2012.

radioactive ion beamPhysicsPhysics::Instrumentation and Detectorsbusiness.industryPhysicsQC1-999DetectorEngineering physicsUpgradeOpticsFragmentation (mass spectrometry)Physics and AstronomyPhysics::Accelerator PhysicsLaser beam qualitytagging systembusinessfragmentation beamBeam (structure)
researchProduct

Potku – New analysis software for heavy ion elastic recoil detection analysis

2014

Time-of-flight elastic recoil detection (ToF-ERD) analysis software has been developed. The software combines a Python-language graphical front-end with a C code computing back-end in a user-friendly way. The software uses a list of coincident time-of- flight–energy (ToF–E) events as an input. The ToF calibration can be determined with a simple graphical procedure. The graphical interface allows the user to select different elements and isotopes from a ToF–E histogram and to convert the selections to individual elemental energy and depth profiles. The resulting sample composition can be presented as relative or absolute concentrations by integrating the depth profiles over user-defined rang…

ta113Nuclear and High Energy PhysicsIon beam analysista114business.industryComputer scienceEvent (computing)Reference data (financial markets)ion beam analysisERDelastic recoil detectionComputational scienceTOF-ERDElastic recoil detectionSoftwareCoincidentHistogramgraphical open source softwarebusinessInstrumentationGraphical user interfaceNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

High speed microfluidic prototyping by programmable proximity aperture MeV ion beam lithography

2013

Abstract Microfluidics refers to the science and technology for controlling and manipulating fluids that flow along microchannels. For the development of complex prototypes, many microfluidic test structures are required first. Normally, these devices are fabricated via photolithography. This technique requires a photomask for transferring a pattern to photoresists by exposing with UV light. However, this method can be slow when a new structure is required to change. This is because a series of photomasks are needed, which is time consuming and costly. Here, we present a programmable proximity aperture lithography (PPAL) technique for the development of microfluidic prototype in poly(methyl…

ta113Nuclear and High Energy PhysicsMaterials scienceFabricationApertureMicrofluidicsProcess (computing)NanotechnologyIon beam lithographylaw.inventionlawta318PhotomaskPhotolithographyInstrumentationLithographyNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Production of a 15C radioactive ion beam based on 18O(n, α)

2019

In the context of the SPIRAL2 radioactive beam facility the production rate of the neutron-rich 15C nucleus by 18O(n,α) has been investigated. In a water target of 20 cm3, enriched in 18O and placed behind the neutron converter, a rate of a few 1010 nuclei per second can be reached with 1mA of 40MeV deuterons. A 18O(n,α) cross-section based on the activation method is proposed. It is intermediate between the highest and lowest evaluations available to date. peerReviewed

tutkimuslaitteetydinfysiikkaion beam productionneutron-rich carbon isotopes
researchProduct