Search results for "Ion cyclotron resonance"

showing 10 items of 96 documents

Mass Spectrometric Investigation of Noncovalent Complexation between a Tetratosylated Resorcarene and Alkyl Ammonium Ions

2004

Noncovalent complexation between tetratosylated tetraethyl resorcarene (1) and primary, secondary, and tertiary alkyl ammonium ions (mMe, dMe, tMe, mEt, dEt, tEt, dBu, and dHex) was studied by electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry. Interactions of the noncovalent complexes were investigated by means of competition experiments, collision-induced dissociation (CID) experiments, ion-molecule reactions with tripropylamine and gas phase H/D-exchange reactions with deuteroammonia. Gas phase ion-molecule reactions gave especially valuable information about the structure and properties of the complexes. Resorcarene 1 formed relatively stable…

IonsSteric effectschemistry.chemical_classificationSpectrometry Mass Electrospray IonizationMolecular StructureMacromolecular SubstancesChemistryHydrogen bondOrganic ChemistryInorganic chemistryGeneral ChemistryCatalysisDissociation (chemistry)Fourier transform ion cyclotron resonanceQuaternary Ammonium CompoundsTosyl Compoundschemistry.chemical_compoundPolymer chemistryProton affinityNon-covalent interactionsAmmoniumAlkylChemistry - A European Journal
researchProduct

The Inchworm as a precision translator in a high magnetic field and UHV environment

1989

Abstract A new set-up has been designed and tested for on-line, high-precision mass measurements of short-lived radioactive isotopes via a determination of the ion cyclotron resonance. Ions delivered by the on-line isotope separator ISOLDE at CERN/Geneva are stored in a Penning trap installed in a superconducting solenoid. Due to severe space limitations in the bore of the solenoid, it is impossible to use conventional mechanical feedthroughs for the necessary manipulations inside the uhv chamber. Instead, a number of Inchworms, a high-precision positioning device based on the piezo-electric effect are employed. This publication reports on the first application of this device in a uhv envir…

Large Hadron ColliderPhysics::Instrumentation and Detectorsbusiness.industryChemistryInstrumentationSeparator (oil production)SolenoidCondensed Matter PhysicsPenning trapSurfaces Coatings and FilmsIonMagnetic fieldNuclear physicsOpticsPhysics::Accelerator PhysicsDetectors and Experimental TechniquesNuclear ExperimentbusinessInstrumentationIon cyclotron resonance
researchProduct

Foodomics assessed by Fourier transform mass spectrometry

2019

Abstract With its ultrahigh resolution power and excellent mass accuracy, Fourier transform ion cyclotron resonance mass spectrometry is the perfct tool to analyze the “foodome” as the set of all polar small molecular compounds present in an investigated food sample. We present here selected applications of this technique in unraveling the metabolome in complex foods (thermally affected, fermentation products, distillates) such exemplified with Maillard reaction products or with wines and spirits. Technical considerations for high resolution mass analyzers are provided from a practical point of view. Moreover, aspects of food safety and nutritional quality are covered by presenting applicat…

Maillard reactionsymbols.namesakeChromatographyUltrahigh resolutionFoodomicsChemistryMetabolomesymbolsHigh resolutionFood sampleNutritional qualityFourier transform ion cyclotron resonance
researchProduct

Quantitative Spatial Analysis of the Mouse Brain Lipidome by Pressurized Liquid Extraction Surface Analysis

2014

Here we describe a novel surface sampling technique termed pressurized liquid extraction surface analysis (PLESA), which in combination with a dedicated high-resolution shotgun lipidomics routine enables both quantification and in-depth structural characterization of molecular lipid species extracted directly from tissue sections. PLESA uses a sealed and pressurized sampling probe that enables the use of chloroform-containing extraction solvents for efficient in situ lipid microextraction with a spatial resolution of 400 μm. Quantification of lipid species is achieved by the inclusion of internal lipid standards in the extraction solvent. The analysis of lipid microextracts by nanoelectrosp…

MaleIn situChromatographyChemistryLiquid-Liquid ExtractionExtraction (chemistry)Analytical chemistryBrainShotgun lipidomicsLipidomeMass spectrometryLipidsMass SpectrometryFourier transform ion cyclotron resonanceAnalytical ChemistryMice Inbred C57BLMiceMicroscopy FluorescenceFragmentation (mass spectrometry)Liquid–liquid extractionSpectroscopy Fourier Transform InfraredPressureAnimalsAnalytical Chemistry
researchProduct

The electron cyclotron resonance ion source with arc-shaped coils concept

2012

The main limitation to further improve the performance of ECR ion sources is set by the magnet technology related to the multipole magnet field used for the closed minimum-B structure. The JYFL ion source group has sought different approaches to improve the strength of the minimum-B structure required for the production of highly charged ion beams. It was found out that such a configuration can be realized with arc shaped coils. The first prototype, electron cyclotron resonance ion source with arc-shaped coils (ARC-ECRIS), was constructed and tested at JYFL in 2006. It was confirmed that such an ion source can be used for the production of highly charged ion beams. Regardless of several cos…

Materials scienceIon beamOptical PhenomenaPlasma Gasesta114Highly charged ionCyclotron resonanceTemperatureParticle acceleratorElectronsCyclotronsModels TheoreticalIon gunIon sourceElectron cyclotron resonancelaw.inventionMagnetic FieldslawAtomic physicsInstrumentationIon cyclotron resonanceReview of Scientific Instruments
researchProduct

Radioactive ion beam manipulation at the IGISOL-4 facility

2020

The IGISOL-4 facility in the JYFL Accelerator Laboratory of the University of Jyvaskyla (JYFL-ACCLAB) produces low-energy radioactive ion beams, primarily for nuclear spectroscopy, utilizing an ion guide-based, ISOL-type mass separator. Recently, new ion manipulation techniques have been introduced at the IGISOL-4 including the application of the PI-ICR (Phase-Imaging Ion Cyclotron Resonance) technique at the JYFLTRAP Penning trap, as well as commissioning of a Multi-Reflection Time-Of-Flight (MR-TOF) separator/spectrometer. The successful operation of the MR-TOF also required significant improvement of the Radio-Frequency Quadrupole (RFQ) cooler and buncher device beam pulse time structure…

Materials scienceSpectrometerIon beamPhysicsQC1-999tutkimuslaitteethiukkaskiihdyttimetPenning trapIon sourceIonNuclear physicsBeamlineIonizationPhysics::Accelerator PhysicsydinfysiikkaNuclear ExperimentIon cyclotron resonanceEPJ Web of Conferences
researchProduct

Electron cyclotron resonance ion source plasma chamber studies using a network analyzer as a loaded cavity probe

2012

A method and first results utilizing a network analyzer as a loaded cavity probe to study the resonance properties of a plasma filled electron cyclotron resonance ion source (ECRIS) plasma chamber are presented. The loaded cavity measurements have been performed using a dual port technique, in which two separate waveguides were used simultaneously. One port was used to ignite and sustain the plasma with a microwave source operating around 11 GHz and the other was used to probe the cavity properties with the network analyzer using a frequency range around 14 GHz. The first results obtained with the JYFL 14 GHz ECRIS demonstrate that the presence of plasma has significant effects on the reson…

Materials scienceta114business.industryCyclotron resonanceResonancePlasmaNetwork analyzer (electrical)Ion sourceElectron cyclotron resonancePhysics::Plasma PhysicsOptoelectronicsAtomic physicsbusinessInstrumentationMicrowaveIon cyclotron resonanceReview of Scientific Instruments
researchProduct

Size- and Structure-Selective Noncovalent Recognition of Saccharides by Tetraethyl and Tetraphenyl Resorcinarenes in the Gas Phase

2008

The noncovalent complexation of tetraethyl and tetraphenyl resorcinarenes with mono-, di-, and oligosaccharides was studied with negative-polarization electrospray ionization quadrupole ion trap and electrospray ionization Fourier-transform ion cyclotron resonance mass-spectrometric analysis. The saccharides formed 1:1 complexes with deprotonated resorcinarenes, which exhibited clear size and structure selectivity in their complexation. In the case of the monosaccharides, hexoses formed much more abundant and kinetically stable complexes than pentoses or deoxyhexoses. A comparison of the mono-, di-, and oligosaccharides revealed that both the relative abundance and stability of the complexe…

Models MolecularCellobiosePhenylalanineElectrospray ionizationCarbohydratesCrystallography X-RayMass spectrometryMass SpectrometryCatalysisSubstrate SpecificityDeprotonationPolymer chemistryCarbohydrate ConformationOrganic chemistryQuadrupole ion trapHost–guest chemistrychemistry.chemical_classificationOrganic ChemistryGeneral ChemistryOligosaccharideResorcinareneKineticschemistryGasesCalixarenesIon cyclotron resonanceChemistry - A European Journal
researchProduct

Alkali metal mediated resorcarene capsules: An ESI-FTICRMS study on gas-phase structure and cation binding of tetraethyl resorcarene and its per-meth…

2002

AbstractElectrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS) with additional ab initio calculations were used to examine the alkali metal cation binding selectivity (i.e., molecular recognition) and host properties of tetraethyl resorcarene (1) and its per-methylated derivative (2). The significance of intramolecular hydrogen bonding for the crown conformation was demonstrated. The presence of intramolecular flip-flop hydrogen bonding in 1 was confirmed both with calculations and in ND3-exchange experiments. All the alkali metal cations formed host–guest complexes by docking inside the cavity of the host. Complexation with the larger cations, esp…

Models MolecularSpectrometry Mass Electrospray IonizationCation bindingFourier AnalysisHydrogen bondChemistryStereochemistryElectrospray ionizationMolecular ConformationHydrogen BondingAlkaliesIon cyclotron resonance spectrometryMethylationFourier transform ion cyclotron resonanceMolecular recognitionMetalsStructural BiologyIntramolecular forcePolymer chemistryMoleculePolycyclic CompoundsSpectroscopyJournal of the American Society for Mass Spectrometry
researchProduct

Mass spectrometric studies on small open-chain piperazine-containing ligands and their transition metal complexes

2001

Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry was used to characterize the complexes formed between open-chain piperazine-containing ligands and transition metal salts (Cobalt, Copper, Zinc, and Cadmium as chlorides, nitrates, and acetates). Only single-charged complexes were observed, formed of one ligand (L) and mainly one metal ion (M). Since the net charge of the complexes was one, a counterion (X) was attached to some of the complexes, with formation of [L + M + X]+ complexes, and a proton was lost from others, as in [L − H + M]+ complexes. In most cases the composition of the complexes was more dependent on the ligand than the metal salt. Collisio…

Models Molecularchemistry.chemical_classificationSpectrometry Mass Electrospray IonizationFourier AnalysisLigandMetal ions in aqueous solutionInorganic chemistryMolecular ConformationCobaltLigandsPiperazinesFourier transform ion cyclotron resonanceNon-innocent ligandStructure-Activity RelationshipZincchemistry.chemical_compoundCrystallographychemistryTransition metalMetalsCarboxylateCounterionMetal aquo complexCopperSpectroscopyJournal of Mass Spectrometry
researchProduct