Search results for "Ion source"
showing 10 items of 337 documents
Production of radioactive Ag ion beams with a chemically selective laser ion source
1997
Abstract We have developed a chemically selective laser ion source at the CERN-ISOLDE facility in order to study neutron-rich Ag nuclides. A pulsed laser system with high repetition rate has been used based on high-power coppe-vapour pump lasers and dye lasers. With this source significant reductions of the isobaric background has been achieved.
Laser systems for on-line laser ion sources
2008
Since its initiation in the middle of the 1980s, the resonant ionization laser ion source has been established as a reliable and efficient on-line ion source for radioactive ion beams. In comparison to other on-line ion sources it comprises the advantages of high versatility for the elements to be ionized and of high selectivity and purity for the ion beam generated by resonant laser radiation. Dye laser systems have been the predominant and pioneering working horses for laser ion source applications up to recently, but the development of all-solid-state titanium:sapphire laser systems has nowadays initiated a significant evolution within this field. In this paper an overview of the ongoing…
Isomer separation of Cu and Cu with a resonance ionization laser ion source
2000
Abstract Radioactive copper isotopes were ionized with the resonance ionization laser ion source (RILIS) at the on-line isotope separator ISOLDE (CERN). Using the different hyperfine structure in the 3d10 4s 2 S1/2 – 3d10 4p 2 P01/2 transition the low- and high-spin isomers of 70 Cu were selectively enhanced by tuning the laser wavelength. The light was provided by a narrow-bandwidth dye laser pumped by copper vapor lasers (CVL) and frequency doubled in a BBO crystal. The ground state to isomeric state intensity ratio could be varied by a factor of 30, allowing to assign gamma transitions unambiguously to the decay of the individual isomers. It is shown that the method can also be used to…
Laser preparation of bunched ion beams
1997
Abstract Laser ionization at ISOLDE is performed with high repetition laser beams in the ion source unit and for daughter elements with low repetition lasers synchronized with laser desorption from a secondary target. We are preparing an implementation of thermal adsorption followed by laser desorption and laser ionization in the target ion source unit of ISOLDE. The combination of resonance ionization with thermal bunching allows the preparation of bunched and chemically pure ion beams. Bunched ion beams of Mg or Ca are prepared for post-acceleration at REX-ISOLDE. In order to investigate the process of adsorption and pulsed laser desorption, experiments are performed with Ba vapour. In a …
MELISSA: Laser ion source setup at CERN-MEDICIS facility. Blueprint
2019
The Resonance Ionization Laser Ion Source (RILIS) has become an essential feature of many radioactive ion beam facilities worldwide since it offers an unmatched combination of efficiency and selectivity in the production of ion beams of many different chemical elements. In 2019, the laser ion source setup MELISSA is going to be established at the CERN-MEDICIS facility, based on the experience of the workgroup LARISSA of the University Mainz and CERN ISOLDE RILIS team. The purpose is to enhance the capability of the radioactive ion beam supply for end users by optimizing the yield and the purity of the final product. In this article, the blueprint of the laser ion source, as well as the key …
Off-line studies of the laser ionization of yttrium at the IGISOL facility
2007
A laser ion source is under development at the IGISOL facility, Jyvaskyla, in order to address deficiencies in the ion guide technique. The key elements of interest are those of a refractory nature, whose isotopes and isomers are widely studied using both laser spectroscopic and high precision mass measurement techniques. Yttrium has been the first element of choice for the new laser ion source. In this work we present a new coupled dye-Ti:Sapphire laser scheme and give a detailed discussion of the results obtained from laser ionization of yttrium atoms produced in an ion guide via joule heating of a filament. The importance of not only gas purity, but indeed the baseline vacuum pressure in…
Implementation of an aerodynamic lens for TRIGA-SPEC
2016
Abstract We report on the optimization of the gas-jet system employed to couple the TRIGA-SPEC experiment to the research reactor TRIGA Mainz. CdI2 aerosol particles suspended in N2 as carrier gas are used for an effective transport of fission products from neutron induced 235 U fission from the target chamber to a surface ion source. Operating conditions of the gas-jet were modified to enable the implementation of an aerodynamic lens, fitting into the limited space available in front of the ion source. The lens boosts the gas-jet efficiency by a factor of 4–10. The characterization of the gas-jet system as well as the design of the aerodynamic lens and efficiency studies are presented and …
RILIS-ionized mercury and tellurium beams at ISOLDE CERN
2017
This paper presents the results of ionization scheme development for application at the ISOLDE Resonance Ionization Laser Ion Source (RILIS). Two new ionization schemes for mercury are presented: a three-step three-resonance ionization scheme, ionizing via an excitation to a Rydberg level and a three-step two-resonance ionization scheme, with a non-resonant final step to the ionization continuum that corresponded to a factor of four higher ionization efficiency. The efficiency of the optimal mercury ionization scheme was measured, together with the efficiency of a new three-step three resonance ionization scheme for tellurium. The efficiencies of the mercury and tellurium ionization schemes…
Effect of the gas mixing technique on the production efficiency of ion beams extracted from an electron cyclotron resonance ion source
2004
In this work the effect of gas mixing on the production efficiency of ion beams extracted from an ECR ion source has been studied with the JYFL 6.4 GHz electron cyclotron resonance ion source (ECRIS). It was found that the gas mixing affects strongly the confinement of ions in the plasma of the ECRIS. The information obtained can be used to minimize the consumption of expensive materials or isotopes and to reduce contamination of the plasma chamber. It was observed that the carbon contamination, which is built up when the MIVOC method is used could be decreased with the aid of the gas mixing technique. The best mixing gas for this purpose was found to be oxygen.
The first results with the new JYFL 14 GHz ECR ion source
2001
Abstract A new 14 GHz ECR ion source has been built for the Accelerator Laboratory in the Department of Physics (JYFL), University of Jyvaskyla. This source belongs to the family of the LBNL AECR-U-based ECR ion sources. The operation during the first four months has shown that the new ion source performs well and is able to produce intensive highly charged ion beams. For example, 145 μA of O7+ ion beam was recorded. The production of iron and boron ion beams was tested using the MIVOC method. The 56Fe11+ ion beam current reached a value of 115 μA. The intensities of 11B3+ and 11B5+ ion beams were 235 and 52 μA, respectively. This iron beam intensity is the second highest and the boron beam…