Search results for "Ionization chamber"

showing 4 items of 34 documents

Correction factors for ionization chamber measurements with the ‘Valencia’ and ‘large field Valencia’ brachytherapy applicators

2018

Treatment of small skin lesions using HDR brachytherapy applicators is a widely used technique. The shielded applicators currently available in clinical practice are based on a tungsten-alloy cup that collimates the source-emitted radiation into a small region, hence protecting nearby tissues. The goal of this manuscript is to evaluate the correction factors required for dose measurements with a plane-parallel ionization chamber typically used in clinical brachytherapy for the 'Valencia' and 'large field Valencia' shielded applicators. Monte Carlo simulations have been performed using the PENELOPE-2014 system to determine the absorbed dose deposited in a water phantom and in the chamber act…

Skin Neoplasmsmedicine.medical_treatmentBrachytherapyPhysics::Medical PhysicsMonte Carlo methodBrachytherapyDose profileRadiationImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsmedicineRadiology Nuclear Medicine and imagingRadiometryValenciaPhysicsRadiological and Ultrasound TechnologybiologyPhantoms ImagingRadiation Dosimetersbusiness.industryRadiotherapy Dosagebiology.organism_classification030220 oncology & carcinogenesisAbsorbed doseIonization chamberbusinessMonte Carlo MethodPhysics in Medicine & Biology
researchProduct

Determination of consensus kQ values for megavoltage photon beams for the update of IAEA TRS-398

2020

The IAEA is currently coordinating a multi-year project to update the TRS-398 Code of Practice for the dosimetry of external beam radiotherapy based on standards of absorbed dose to water. One major aspect of the project is the determination of new beam quality correction factors, kQ, for megavoltage photon beams consistent with developments in radiotherapy dosimetry and technology since the publication of TRS-398 in 2000. Specifically, all values must be based on, or consistent with, the key data of ICRU Report 90. Data sets obtained from Monte Carlo (MC) calculations by advanced users and measurements at primary standards laboratories have been compiled for 23 cylindrical ionization chamb…

TRS-398INMRImedicine.medical_treatmentMonte Carlo method030218 nuclear medicine & medical imagingNuclear physics03 medical and health sciences0302 clinical medicinemedicineRelative biological effectivenessDosimetryRadiology Nuclear Medicine and imagingExternal beam radiotherapyMonte CarloPhysicsMV photon beamsRadiological and Ultrasound Technologydosimetryionization chambersmetrologymetrologia030220 oncology & carcinogenesisAbsorbed doseIonization chamberPhoton beamsbeam quality correction factorsLaser beam quality
researchProduct

Direct Measurement of Mammographic X-Ray Spectra with a Digital CdTe Detection System

2012

In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate X-ray spectroscopy in mammography (1–30 keV). The DPP system performs a height and shape analysis of the detector pulses, sampled and digitized by a 14-bit, 100 MHz ADC. We show the results of the characterization of the detection system both at low and high photon counting rates by using monoenergetic X-ray sources and a nonclinical X-ray tube. The detection system exhibits excellent performance up to 830 kcps with an energy resolution of 4.5% FWHM at 22.1 keV. Direct measurements of clinical molybdenum X-ray spectra were carried out by using a pinhole…

digital pulse processingmammographyAnalytical chemistrylcsh:Chemical technologyBiochemistryArticleAnalytical ChemistryCdTe detectorsCdTe detectorOpticsmedicineCadmium CompoundsMammographylcsh:TP1-1185Computer SimulationElectrical and Electronic EngineeringInstrumentationPhysicsDosimetermedicine.diagnostic_testbusiness.industryAttenuationSpectrum AnalysisX-RaysDetectorSettore FIS/01 - Fisica Sperimentalehigh photon counting rateCdTe detectors Digital Pulse Processing MammographySignal Processing Computer-AssistedAtomic and Molecular Physics and OpticsPhoton countingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Full width at half maximumX-ray spectroscopy; high photon counting rate; CdTe detectors; digital pulse processing; mammographyIonization chamberX-ray spectroscopyTelluriumbusinessHalf-value layerSensors; Volume 12; Issue 6; Pages: 8390-8404
researchProduct

Instrumentation for time-of-flight elastic recoil detection analysis

2016

Time-of-flight elastic recoil detection is an ion beam based method to analyze the elemental composition of thin film samples at different depths. In order to improve the mass resolution and to enable kinematic correction a position sensitive gas ionization chamber energy detector was constructed. This detector along with pre-existing timing detectors were connected to a modern fully digitizing data acquisition setup. This thesis describes the design of these instruments, including all aspects from the mechanical design of the gas ionization detector to the algorithm and software development of the digitizing acquisition setup. The performance of the system has been studied with measurements …

digital pulse processingmateriaalitutkimusanalyysilaitteetelastic recoil detection analysisanalyysimenetelmätsirontaohutkalvottime-of-flightgas ionization chamberdigitizerdigitaalitekniikka
researchProduct