Search results for "Ionization."

showing 10 items of 1229 documents

Comparison of direct mass spectrometry methods for the on-line analysis of volatile compounds in foods

2013

For the on-line monitoring of flavour compound release, atmospheric pressure chemical ionization (APCI) and proton transfer reaction (PTR) combined to mass spectrometry (MS) are the most often used ionization technologies. APCI-MS was questioned for the quantification of volatiles in complex mixtures, but direct comparisons of APCI and PTR techniques applied on the same samples remain scarce. The aim of this work was to compare the potentialities of both techniques for the study of in vitro and in vivo flavour release. Aroma release from flavoured aqueous solutions (in vitro measurements in Teflon bags and glass vials) or flavoured candies (in vivo measurements on six panellists) was studie…

Detection limitChromatography010504 meteorology & atmospheric sciencesbiologyChemistry010401 analytical chemistryFlavourAnalytical chemistryAtmospheric-pressure chemical ionizationRepeatabilityMass spectrometrybiology.organism_classification01 natural sciences0104 chemical sciencesAdsorptionIonizationSpectroscopyAroma0105 earth and related environmental sciencesJournal of Mass Spectrometry
researchProduct

Resin and fatty-acid analysis by solid-phase extraction coupled to atmospheric pressure chemical ionization–mass spectrometry

2007

Using gas-chromatographic analysis, the suitability of liquid–liquid extraction and solid-phase extraction (SPE) methods was studied for the rapid separation of resin and fatty-acid fractions from papermaking process waters. In the second phase of this study, a novel procedure (correlation coefficient >0.99 and repeatability RSD <8%) for on-line monitoring of selected individual acid components (limits of detection 11–78 µg L−1) by SPE combined with atmospheric pressure chemical ionization–mass spectrometry was developed. The suitability of this technique for quality control of papermaking process waters was tested by means of industrial samples. The method was also found suitable for the a…

Detection limitChromatographyAtmospheric pressureChemistryHealth Toxicology and MutagenesisPapermakingExtraction (chemistry)Public Health Environmental and Occupational HealthAnalytical chemistrySoil ScienceAtmospheric-pressure chemical ionizationRepeatabilityMass spectrometryPollutionAnalytical ChemistryEnvironmental ChemistrySolid phase extractionWaste Management and DisposalWater Science and TechnologyInternational Journal of Environmental Analytical Chemistry
researchProduct

Liquid Chromatography Quadrupole Time-of-Flight Mass Spectrometry Analysis of Carbosulfan, Carbofuran, 3-Hydroxycarbofuran, and Other Metabolites in …

2007

The potential of liquid chromatography quadrupole time-of-flight mass spectrometry (LC-QqTOF-MS) to identify and confirm carbosulfan and seven of its main metabolites (carbofuran, 3-hydroxycarbofuran, 3-ketocarbofuran, 3-hydroxy-7-phenol carbofuran, 3-keto-7-phenolcarbofuran, 7-phenolcarbofuran, dibutylamine) at trace levels from food is explored for the first time. The analytical method developed consists of pressurized liquid extraction (PLE) and LC-QqTOF-MS in positive ion mode, which attains unequivocal identification and quantification of the studied compounds in food, at levels well below of those of concern (0.05 mg/kg for the sum of carbosulfan, carbofuran, and 3-hydroxycarbofuran).…

Detection limitChromatographyMolecular StructureMetaboliteRepeatabilityButylaminesMass spectrometrySensitivity and SpecificityAnalytical ChemistryDibutylamineCarbofuranchemistry.chemical_compoundchemistrySpectrometry Mass Matrix-Assisted Laser Desorption-IonizationCarbosulfanCarbamatesQuantitative analysis (chemistry)CarbofuranFood AnalysisChromatography LiquidAnalytical Chemistry
researchProduct

Improving detection limits for organotin compounds in several matrix water samples by derivatization-headspace-solid-phase microextraction and GC-MS.

2010

Triethyltin, tributyltin, diphenyltin and triphenyltin were selected as model compounds. The method is based on in situ ethylation and simultaneous headspace-solid-phase microextraction (HS-SPME) and gas chromatographic-mass spectrometry analysis (GC-MS). The extraction procedure was optimized studying some variables such as reaction time, salinity, sample volume and headspace volume. SPME-GC-MS and SPME-GC-FID techniques were compared; quality assurance parameters such as sensitivity, selectivity and precision were established. The proposed procedure showed limits of detection between 0.025 and 1 ng/L. The linearity was in the 0.025-5000 ng/L range. The precision expressed as relative stan…

Detection limitCromatografia de gasosChromatographyAnalytical chemistrySolid-phase microextractionAnalytical Chemistrylaw.inventionMatrix (chemical analysis)chemistry.chemical_compoundchemistrylawFlame ionization detectorSample preparationGas chromatographyCompostos organometàl·licsAigües residuals AnàlisiGas chromatography–mass spectrometryDerivatizationTalanta
researchProduct

Development of a pressurised liquid extraction and liquid chromatography with electrospray ionization-tandem mass spectrometry method for the determi…

2006

Amnesic shellfish poisoning (ASP) is a potentially lethal human toxic syndrome which is caused by domoic acid (DA) that originates in marine phytoplankton belonging to the Pseudonitzschia genus. A confirmatory and sensitive procedure has been developed and validated for the determination of DA in shellfish. The proposed method includes pressurised liquid extraction (PLE) with methanol/acetone (9:1), florisil ® cleanup purification inside the PLE extraction cell and detection by liquid chromatography (LC) coupled to electrospray ionization in positive mode tandem mass spectrometry (ESI-MS–MS). Comparison of ionization sources (ESI, atmospheric pressure ionization (APCI) atmospheric pressure …

Detection limitElectrospraySpectrometry Mass Electrospray IonizationChromatographyKainic AcidElectrospray ionizationOrganic ChemistryAnalytical chemistryDomoic acidAtmospheric-pressure chemical ionizationGeneral MedicineTandem mass spectrometryBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical Chemistrychemistry.chemical_compoundchemistryTandem Mass SpectrometryAmnesic shellfish poisoningAnimalsChromatography LiquidShellfishJournal of chromatography. A
researchProduct

Zwitterionic Sulfonates as m/z Shift Reagents for 5-Methylcytosine Detection in Deoxyribonucleic Acids (DNA) Using Flow Injection Analysis and Electr…

2015

5-Methylcytosine (5-MC) is an important epigenetic modification of DNA. Abnormally high concentrations of this substance appear because of the hypermethylation of cytosine. Therefore, the measurement of the quantity of this compound in mammals is of great importance. Recently, we reported that several imidazolium-based zwitterionic sulfonates form complexes with 5-MC in solution, which can be studied by electrospray ionisation mass spectrometry (ESI-MS). It is shown in this paper that such an association can be utilised for the detection of 5-MC in a DNA sample using high-throughput a flow injection analysis ESI-MS method. A variety of the sulfonate zwitterions have been tested as m/ z shi…

Detection limitFlow injection analysisSpectrometry Mass Electrospray IonizationElectrosprayChromatographyChemistryElectrospray ionizationAnalytical chemistryReproducibility of ResultsDNAGeneral MedicineDNA MethylationTandem mass spectrometryMass spectrometryAtomic and Molecular Physics and OpticsSample preparation in mass spectrometryFlow Injection Analysis5-MethylcytosineAnimalsCattleA-DNASulfonic AcidsSpectroscopyEuropean Journal of Mass Spectrometry
researchProduct

Development of an ICP-IDMS method for accurate routine analyses of toxic heavy metals in polyolefins and comparison with results by TI-IDMS

2000

An inductively coupled plasma isotope dilution mass spectrometric (ICP-IDMS) method was developed as a suitable method - with respect to its sensitivity, precision, accuracy, and time-consumption - for the analysis of toxic heavy metal traces (Pb, Cd, Cr, and Hg) in polyolefins. Results for Pb, Cd, and Cr were compared with those obtained by thermal ionization isotope dilution mass spectrometry (TI-IDMS), which was used as a reference method. Because of its high first ionization potential and its high volatility mercury could not be determined by TI-IDMS. A multi-element spike solution, containing isotopically enriched 206Pb, 116Cd, 53Cr, and 201Hg, was used for the isotope dilution step. D…

Detection limitIsotopeChemistryAnalytical chemistryThermal ionizationchemistry.chemical_elementAlkenesIsotope dilutionMass spectrometrySensitivity and SpecificityBiochemistryHazardous SubstancesMass SpectrometryMercury (element)IsotopesPolyethyleneMetals HeavyInductively coupled plasmaChemical decompositionFresenius' Journal of Analytical Chemistry
researchProduct

Trace analysis of plutonium in environmental samples by resonance ionization mass spectroscopy (RIMS)

1998

Resonance ionization mass spectroscopy (RIMS) is well suited for trace analysis of long-lived radioisotopes in environmental, biological and technical samples. By multiple resonant laser excitation and ionization of the elemental atoms under investigation, an extremely high element selectivity can be achieved. In addition, isotope selectivity is obtained by subsequent mass analysis. The excellent sensitivity results from the large atomic cross-sections in the excitation–ionization process and the good detection efficiency for ions. The element selectivity of RIMS allows a simplified procedure for the chemical preparation of the samples compared to the requirements of thin sources for α-spec…

Detection limitIsotopeChemistryMechanical EngineeringMetals and AlloysAnalytical chemistrychemistry.chemical_elementMass spectrometryIonPlutoniumMechanics of MaterialsIonizationMaterials ChemistryPhysics::Atomic PhysicsTransuranium elementExcitationJournal of Alloys and Compounds
researchProduct

Ultratrace analysis and isotope ratio measurements of long-lived radioisotopes by resonance ionization mass spectrometry (RIMS).

2003

Resonance Ionization Mass Spectrometry (RIMS) is a sensitive and selective method for ultratrace analysis of long-lived radioisotopes and isotope ratio measurements. It provides extremely high isobaric suppression and good overall efficiency. The experimental limits of detection are as low as 10(6) atoms per sample and isotopic selectivities of 5x10(12) have been obtained. The widespread potential of RIMS, using different experimental arrangements, is demonstrated for the determination of the radiotoxic isotopes Pu-238 to Pu-244 and Sr-89/Sr-90 in various environmental samples as well as for Ca-41 in nuclear reactor components and biomedical samples.

Detection limitIsotopeChemistryRadiochemistryAnalytical chemistryIsobaric processPlutonium-244Thermal ionization mass spectrometryMass spectrometryBiochemistryStrontium-90Analytical ChemistryPlutonium-238Analytical and bioanalytical chemistry
researchProduct

Resonance ionization mass spectrometry for ultratrace analysis of plutonium with a new solid state laser system

2004

Abstract Resonance ionization mass spectrometry (RIMS) is well-suited for isotope selective ultratrace analysis of long-lived radioactive isotopes due to its high element and isotope selectivity and good sensitivity. For the analysis of plutonium with a pulsed RIMS apparatus, a powerful, reliable and easy to handle Nd:YAG pumped titanium–sapphire laser system has been developed and combined with a time-of-flight mass spectrometer. Spectroscopic measurements led to an efficient three step excitation and ionization scheme for plutonium with λ1 = 420.76 nm, λ2 = 847.28 nm, and λ3 = 767.53 nm. The isotope shifts in this scheme for the plutonium isotopes 238 Pu through 244 Pu have been determine…

Detection limitIsotopeChemistryRadiochemistryAnalytical chemistrychemistry.chemical_elementThermal ionization mass spectrometryCondensed Matter PhysicsLaserMass spectrometrylaw.inventionPlutoniumSolid-state laserlawIonizationPhysical and Theoretical ChemistryInstrumentationSpectroscopyInternational Journal of Mass Spectrometry
researchProduct