Search results for "Ionomer"
showing 10 items of 76 documents
Effect of different polishing techniques on surface roughness and bacterial adhesion of three glass ionomer-based restorative materials : in vitro st…
2020
Background Although many reports concluded that polishing of glass ionomers is crucial for smoother surface and limiting the adhesion of cariogenic bacteria, there is no specific surface treatment protocol recommended. A novel material in the same category was released recently claimed to have surface smoothness comparable to resin composite and bacterial adhesion less than other types of glass ionomers. In this study, different polishing systems were tested with three glass ionomers one of them is the novel material to find the most appropriate polishing protocol. Objectives: To evaluate and compare the surface roughness and bacterial adhesion to resin modified glass ionomer, bioactive ion…
Effect of mouthwashes on the integrity of composite resin and resin modified glass ionomer : in vitro study
2018
Background The constant search for an improved esthetic dental material has led investigators to realize that its performance depends on the conditions where the material is used. It has been probed that the contact with mouth rinses triggers alterations, reason why the aim of this study was to identify their possible effects of it on the integrity of nanohybrid composite resin and resin modified glass ionomer. Material and methods A total of 144 samples were manufactured with two nanohybrid composite resins and two resin modified glass ionomer restorative materials. The specimens were immersed in one of the three mouthwashes used in the study, for a total of 1092 minutes, with intervals of…
The effect of short polyethylene fiber with different weight percentages on diametral tensile strength of conventional and resin modified glass ionom…
2017
Background The aim of this study was to investigate the effect of polyethylene fiber on diametral tensile strength of conventional and resin modified glass ionomer cements. Material and Methods 60 specimens in 6 groups (n=10) were prepared. In group 1 conventional glass ionomer (Fuji GC) and in group 2 resin modified glass ionomer (Fuji LC) were as control groups. In group 3 and 4 conventional glass ionomers mixed with short polyethylene fibers in proportion of 1 wt% and 3 wt%, respectively. In fifth and sixth groups, resin modified glass ionomer and short polyethylene fibers were mixed in 1 and 3% wt, respectively. Samples were prepared in a round brass mold (6.5×2.5 mm). After thermo-cycl…
Comparison between the effect of adding microhydroxyapatite and chitosan on surface roughness and Microhardness of resin modified and conventional gl…
2019
Background This study aimed to compare the effect of chitosan (CH) and hydroxyapatite (HP) on the surface roughness and microhardness of a conventional glass ionomer cement (CGIC) and a resin modified glass ionomer cement (RMGIC). Material and Methods 60 disk-shaped specimens (2mm x 6mm) were prepared in 6 groups; group I: CGIC, group II: RMGIC, group III: CGIC + 15% volume CH solution in liquid, group IV: CGIC +10% weight micro-HP in powder, group V: RMGIC + 15% volume CH, group VI: RMGIC + 10% weight micro-HP. After storage in deionized water at room temperature for 24 hours, the surface roughness and microhardness of the specimens were measured using a surface profilometer and Vickers mi…
Effect of addition of bioactive glass to resin modified glass ionomer cement on enamel demineralization under orthodontic brackets
2019
Background Enamel demineralization and white spot lesions around orthodontic brackets is a common problem associated with fixed orthodontic treatment. Glass ionomer cements (GICs) are commonly used for bracket bonding and recently, bioactive glass (BAG) was added to GICs to enhance deposition of calcium phosphate in adjacent dental structure. This study sought to assess the effect of addition of BAG particles to resin modified GIC (RMGIC) on enamel demineralization under orthodontic brackets. Material and methods In this in vitro, experimental study, 60 sound human premolars were immersed in distilled water at 6°C. The teeth were randomly divided into three groups. Using a sticker, a window…
Remineralization effects of conventional and experimental ion-releasing materials in chemically or bacterially-induced dentin caries lesions
2019
Abstract Objectives The aim of this study was to evaluate the remineralization effects of conventional and experimental ion-releasing materials on different artificial dentin carious lesions. Methods Forty human dentin discs were submitted to different demineralization protocols for simulated caries lesion: (D1) Shallow chemically-induced caries, (D2) deep chemically-induced caries, (D3) deep bacterially-induced caries. Each disc was divided in five parts; one of those served as baseline control. The remaining parts of each disc (n = 12–16/group) were treated using the following materials: EXP, an experimental resin-based bioactive material consisting of a self-etch primer and an adhesive c…
Microleakage comparison of glass-ionomer and white mineral trioxide aggregate used as a coronal barrier in nonvital bleaching
2011
Objectives: There is some evidence that the pH at the root surface is reduced by intracoronal placement of bleaching pastes, which is known to enhance osteoclastic activity. Therefore, it is recommended that a protective barrier be used over the canal filling to prevent leakage of bleaching agents. Glass-ionomer (GI) is commonly used as a coronal barrier before nonvital bleaching. Because mineral trioxide aggregate (MTA) creates high alkalinity after mixing with water, using MTA as a protective barrier over the canal filling may not only prevent leakage of bleaching agents and microorganisms, but may prevent cervical resorption. The aim of this study was to evaluate sealing ability of white…
A laboratory comparison of Individual Targis/Vectris posts with standard fiberglass posts
2007
This article presents an in vitro analysis of a specific occlusal loading test on endodontically treated teeth restored with 2 different composite post materials. Individual, customized posts (IFPs) were compared to standard fiberglass posts (SFPs). The selected IFPs (standard cylindric Targis/Vectris posts) were compared to SFPs (Conic 6% Post, Ghimas). The posts were first subjected to a 3-point bending test to compare their flexural elastic properties. They were then used to restore 22 endodontically treated artificial maxillary central incisors and subjected to a specific occlusal loading simulation test. The loading test showed that IFP restorations performed better than SFP restoratio…
Reactive compatibilization of PA6/LDPE blends with an ethylene–acrylic acid copolymer and a low molar mass bis-oxazoline
2003
Abstract A sample of polyamide-6 (PA) was blended with low density polyethylene (LDPE) in the 80/20 wt/wt ratio, either without and with 2 phr of an ethylene–acrylic acid copolymer (EAA), Which was known to behave as a compatibilizer precursor, and the effect of the addition of small amounts (0.2 or 0.35 phr) of a fourth component, 2,2′-(1,3-phenylene)-bis(2-oxazoline) (PBO), was investigated. The reactions of PBO with EAA, PA and their blends were studied by recording as a function of time the torque applied to the blending apparatuses and by studying the solubility behavior of the products in formic acid. The PALDPE blends were prepared in a co-rotating twin screw extruder and were charac…
A preliminary clinical trial using flowable glass-ionomer cement as a liner in proximal-ART restorations: the operator effect
2013
Objectives: This in vivo study was carried out to assess the influence of the operator experience on the survival rate of proximal-ART restorations using a two-layer technique to insert the glass-ionomer cement (GIC). Study Design: Forty five proximal cavities in primary molars were restored in a school setting according to the ART technique. The cavities were restored by two operators with Ketac Molar Easymix, and received a flowable layer of GIC prior to a second GIC layer with a regular consistency. The operators had different clinical experiences with ART (no experience or two years of experience), but both completed a one-week training to perform the restorations and the GIC mixing in …