Search results for "Iridium"
showing 6 items of 296 documents
Ligand-Centred Fluorescence and Electronic Relaxation Cascade at Vibrational Time Scales in Transition-Metal Complexes
2015
Using femtosecond-resolved photoluminescence up-conversion, we report the observation of the fluorescence of the high-lying ligand-centered (LC) electronic state upon 266 nm excitation of an iridium complex, Ir(ppy)(3), with a lifetime of 70 +/- 10 fs. It is accompanied by a simultaneous emission of all lower-lying electronic states, except the lowest triplet metal-to-ligand charge-transfer ((MLCT)-M-3) state that shows a rise on the same time scale. Thus, we observe the departure, the intermediate steps, and the arrival of the relaxation cascade spanning similar to 1.6 eV from the (LC)-L-1 state to the lowest 3MLCT state, which then yields the long-lived luminescence of the molecule. This …
Otrējo spirtu dinamiskā kinētiskā sadalīšana
2019
Antrinių alkoholių dinaminė kinetinė rezoliucija. Simonas Balkaitis. Darbo vadovas: Dr. chem. Artis Kinēns. Magistrinį darbą sudaro 63 puslapiai, 10 iliustracijų, 31 schema, 14 lentelių, 1 lygtis, 53 literatūros šaltiniai. Darbas parašytas anglų kalba. Pirmiausia buvo ištirta antrinių alkoholių racemizacija įvairių iridžio, rutenio ir geležies katalizatorių pagalba. Tuomet, racemizacijai tinkamiausiuose tirpiklių variantuose buvo tiriama alkoholių kinetinė rezoliucija. Gauti duomenys buvo panaudoti naujos dinaminės kinetinės rezoliucijos procedūros paieškose.
Determination of platinum and iridium in reforming catalysts by second derivative and absorptiometric spectrophotometry
1991
Investigations on the spectrophotometric determination of platinum as a complex formed by tin(II)chloride in hydrochloric acid are reported. The determination of platinum was found to be interfered with by iridium, because it also forms a complex with tin(II) chloride. The features of the derivative absorption spectrophotometry for the quantitative determination of platinum and iridium was also studied. The analytical application of the method for the determination of platinum and iridium in catalysts was investigated.
Broad-beam transmission data for new brachytherapy sources, Tm-170 and Yb-169
2005
The characteristics of the radionuclides (170)Tm and (169)Yb are highly interesting for their use as high dose-rate brachytherapy sources. The introduction of brachytherapy equipment containing these sources will lead to smaller required thicknesses of the materials used in radiation protection barriers compared with the use of conventional sources such as (192)Ir and (137)Cs. The purpose of this study is to determine the required thicknesses of protection material for the design of the protecting walls. Using the Monte Carlo method, transmission data were derived for broad-beam geometries through lead and concrete barriers, from which the first half value layer and tenth value layer are ob…
In vitro comparison of platinum-iridium and gold tip electrodes: lesion depth in 4 mm, 8 mm, and irrigated-tip radiofrequency ablation catheters
2009
Aims We compared a newly developed irrigated gold tip electrode ablation catheter and a gold tip 4 and 8 mm catheter with the corresponding platinum–iridium (Pt) tip catheters in an in vitro setting. Methods and results In a flow chamber simulating physiological flow conditions, radiofrequency catheter ablation was performed on tissue samples of porcine endomyocardium and liver. Lesion depth, energy and temperature delivery, and popping frequency were determined. Two hundred and fifty-three ablations were conducted. Four and eight millimetre, gold tip electrode catheters produced significantly deeper lesions compared with the Pt tip electrode (liver 4 mm: 4.67 ± 1.7 vs. 2.9 ± 1.0 mm, P < 0.…
CCDC 1490706: Experimental Crystal Structure Determination
2017
Related Article: Diego Rota Martir, Cristina Momblona, Antonio Pertegás, David B. Cordes, Alexandra M. Z. Slawin, Henk J. Bolink, and Eli Zysman-Colman|2016|ACS Applied Materials and Interfaces|8|33907|doi:10.1021/acsami.6b14050