Search results for "Isometric Contraction"

showing 10 items of 237 documents

Bilateral and Unilateral Neuromuscular Function and Muscle Cross-Sectional Area in Middle-Aged and Elderly Men and Women

1996

Forty-eight healthy men (M) and women (W), divided into two different age groups, i.e., M50 yrs (range 44-57; n = 12), W50 yrs (range 43-57; n = 12), M70 yrs (range 59-75; n = 12), and W70 yrs (range 62-75; n = 12), volunteered as subjects for examination of muscle cross-sectional area (CSA), maximal voluntary forces, force-time curves, and electromyographic activity of the knee extensor muscles during bilateral and unilateral isometric contractions. The maximal bilateral knee extension force and the average CSA values in M50 were greater (p < .05) than in M70 and in W50 were greater (p < .05-.001) than those recorded for W70. The early forces in the force-time curve were greater (p < .05) …

AdultMaleMuscle tissueAgingmedicine.medical_specialtyIsometric exerciseElectromyographyKnee extensionAge groupsIsometric ContractionInternal medicineMaximal strengthmedicineHumansKneeAgedmedicine.diagnostic_testKnee extensorsElectromyographybusiness.industryMusclesAnatomyMiddle AgedMuscle Fibers Slow-Twitchmedicine.anatomical_structureMuscle Fibers Fast-TwitchCardiologyFemaleGeriatrics and GerontologyOlder peoplebusinessThe Journals of Gerontology Series A: Biological Sciences and Medical Sciences
researchProduct

Muscle cross-sectional area and voluntary force production characteristics in elite strength- and endurance-trained athletes and sprinters

1989

Seven male elite strength-trained athletes (SA) from different weight categories, six elite sprinters (SPA) and seven elite endurance-trained athletes (EA) volunteered as subjects for examination of their muscle cross-sectional area (CSA), maximal voluntary isometric force, force-time and relaxation-time characteristics of the leg extensor muscles. The SA group demonstrated slightly greater CSA and maximal absolute strength than the SPA group, while the EA group demonstrated the smallest values both in CSA and especially in maximal strength (p<0.05). When the maximal forces were related to CSA of the muscles, the mean value for the SA group of 60.8±10.0 N·cm−2 remained slightly greater than…

AdultMaleMuscle tissuemedicine.medical_specialtyPhysiologyIsometric exerciseIsometric ContractionPhysiology (medical)Internal medicinemedicineHumansOrthopedics and Sports MedicineExercise physiologyExercisebiologybusiness.industryAthletesMusclesMean valuePublic Health Environmental and Occupational HealthGeneral Medicinebiology.organism_classificationCross section (geometry)medicine.anatomical_structureEndocrinologySprintTurnoverPhysical EndurancePhysical therapybusinessEuropean Journal of Applied Physiology and Occupational Physiology
researchProduct

Should Exercises be Painful or not? Effects on Clinical and Experimental Pain in Individuals with Shoulder Pain

2021

Exercise can reduce pain, however the effect of painful versus non-painful exercises is uncertain. The primary aim of this randomized crossover study was to compare the effect of painful versus nonpainful isometric shoulder exercises on pain intensity after exercise in individuals with rotator cuff-related shoulder pain. Secondary exploratory aims were to describe the effects on pressure pain thresholds (PPTs), conditioned pain modulation (CPM) and muscle strength. On separate days, 35 individuals performed painful isometric shoulder exercises (external rotation; 20% above pain threshold), nonpainful isometric shoulder exercises (external rotation; 20% below pain threshold), and a rest cond…

AdultMalePain Thresholdmedicine.medical_specialtyVisual analogue scalePainIsometric exerciseIsometric exerciseRotator Cuff03 medical and health sciences0302 clinical medicineShoulder Pain030202 anesthesiologyIsometric ContractionThreshold of painmedicineHumansMuscle StrengthExercisePressure pain thresholdbusiness.industryOutcome measuresMiddle AgedExercise induced analgesiaCrossover studyExercise TherapyAnesthesiology and Pain MedicineNeurologyConditioned pain modulationExternal rotationShoulder exercisesRotator cuff-related shoulder painPhysical therapyFemaleNeurology (clinical)Analgesiabusinesshuman activities030217 neurology & neurosurgeryThe Journal of Pain
researchProduct

Non‐uniform displacement within ruptured Achilles tendon during isometric contraction

2021

The purpose of this study was investigate tendon displacement patterns in non-surgically treated patients 14 months after acute Achilles tendon rupture (ATR) and to classify patients into groups based on their Achilles tendon (AT) displacement patterns. Twenty patients were tested. Sagittal images of AT were acquired using B-mode ultrasonography during ramp contractions at a torque level corresponding to 30% of the maximal isometric plantarflexion torque of the uninjured limb. A speckle tracking algorithm was used to track proximal-distal movement of the tendon tissue at 6 antero-posterior locations. Two-way repeated measures ANOVA for peak tendon displacement was performed. K-means cluster…

AdultMalePhysical Therapy Sports Therapy and RehabilitationIsometric exercise030204 cardiovascular system & hematologyAchilles Tendon03 medical and health sciences0302 clinical medicineIsometric ContractionmedicineHumansOrthopedics and Sports MedicineDisplacement (orthopedic surgery)UltrasonographyRuptureAchilles tendonbusiness.industryRepeated measures designRecovery of Function030229 sport sciencesAnatomyMiddle AgedRuptured achilles tendonSagittal planeBiomechanical PhenomenaTendonmedicine.anatomical_structureTorqueFemaleAchilles tendon rupturemedicine.symptombusinessAlgorithmsFollow-Up StudiesScandinavian Journal of Medicine &amp; Science in Sports
researchProduct

Force and EMG power spectrum during eccentric and concentric actions

2000

This study was designed to examine the force and activation levels of elbow flexor muscles during preactivated eccentric, concentric and isometric actions.Force, average EMG (aEMG), and the EMG power spectrum were investigated at different constant movement velocities (1 rad x s(-1), 2 rad x s(-1), 3 rad x s(-1), and 4 rad x s(-1)) at different joint angles.Average force at a 110 degree elbow angle was lower and aEMG was higher in concentric actions as compared with eccentric and isometric actions. At a 55 degree elbow angle, there was no difference in aEMG, or it was slightly higher in eccentric actions. MF was higher in the concentric as compared with eccentric actions at the three fastes…

AdultMalePhysicsmedicine.medical_specialtyElbow flexormedicine.diagnostic_testElectromyographyMovementElbowSpectral densityPhysical Therapy Sports Therapy and RehabilitationElectromyographyAnatomyConcentricMotor unitmedicine.anatomical_structurePhysical medicine and rehabilitationIsometric ContractionElbowmedicineHumansEccentricOrthopedics and Sports Medicinemedicine.symptomMuscle contractionMedicine &amp; Science in Sports &amp; Exercise
researchProduct

Effect of electrode location on surface electromyography changes due to eccentric elbow flexor exercise.

2009

Experiments were carried out to determine whether the location of electrodes has an effect on eccentric exercise–induced changes in surface electromyography (sEMG) variables in the biceps brachii muscle. sEMG signals were recorded with a grid of 64 electrodes before and up to 4 days post-exercise. Root mean square (RMS) and mean power frequency (MNF) were calculated for: (1) each channel; (2) as an average of all channels; and (3) as an average of individual channel rows and columns. Mean muscle-fiber conduction velocity (CV) was estimated similarly but was based on double-differential channels. Maximal isometric voluntary torque decreased 21.3 ± 5.6% post-exercise. The average sEMG variabl…

AdultMalePhysiologyMuscle Fibers SkeletalPainElectromyographyIsometric exerciseNerve conduction velocityRoot mean squareCellular and Molecular NeurosciencePhysiology (medical)Isometric ContractionmedicineElbowEccentricHumansMuscle SkeletalElectrodesExerciseMathematicsMuscle fatiguemedicine.diagnostic_testBiceps brachii muscleElectromyographySignal Processing Computer-AssistedAnatomyElectrode locationNeurology (clinical)Biomedical engineeringMuscle ContractionMusclenerve
researchProduct

Bipedal distribution of human vestibular‐evoked postural responses during asymmetrical standing

2002

Galvanic vestibular stimulation (GVS) evokes responses in muscles of both legs when bilateral stimuli are applied during normal stance. We have used this technique to assess whether asymmetrical standing alters the distribution of responses in the two legs. Subjects stood either asymmetrically with 75% of their body weight on one leg or symmetrically with each leg taking 50% of their body weight. The net response in each leg was taken from changes in ground reaction force measured from separate force plates under each foot. The net force profile consisted of a small initial force change that peaked at approximately 200 ms followed by an oppositely directed larger component that peaked at ap…

AdultMalePhysiologyPostureElectromyographyFunctional LateralityIsometric ContractionmedicineHumansForce platformGround reaction forceGalvanic vestibular stimulationBalance (ability)PhysicsVestibular systemLegmedicine.diagnostic_testElectromyographyFootOriginal ArticlesAnatomyHorizontal planeHead MovementsLinear ModelsVestibule LabyrinthTilt (camera)GravitationThe Journal of Physiology
researchProduct

Effects of muscle action type on corticospinal excitability and triceps surae muscle-tendon mechanics.

2018

This study investigated whether the specific motor control strategy reported for eccentric muscle actions is dependent on muscle mechanical behavior. Motor evoked potentials, Hoffman reflex (H-reflex), fascicle length, pennation angle, and fascicle velocity of soleus muscle were compared between isometric and two eccentric conditions. Ten volunteers performed maximal plantarflexion trials in isometric, slow eccentric (25°/s), and fast eccentric (100°/s) conditions, each in a different randomized testing session. H-reflex normalized by the preceding M wave (H/M) was depressed in both eccentric conditions compared with isometric ( P &lt; 0.001), while no differences in fascicle length and pe…

AdultMalePhysiologyPyramidal TractsH-ReflexTendons03 medical and health sciences0302 clinical medicineMuscle actionTriceps surae muscleIsometric ContractionMedicineEccentricHumansta315Muscle Skeletalbusiness.industryGeneral NeuroscienceMotor control030229 sport sciencesTendonBiomechanical Phenomenamedicine.anatomical_structurecorticospinal excitabilitymotor evoked potentialsbusinessNeuroscience030217 neurology & neurosurgerymuscle-tendon dynamicsJournal of neurophysiology
researchProduct

Activation of human quadriceps femoris during isometric, concentric, and eccentric contractions.

2001

Maximal and submaximal activation level of the right knee-extensor muscle group were studied during isometric and slow isokinetic muscular contractions in eight male subjects. The activation level was quantified by means of the twitch interpolation technique. A single electrical impulse was delivered, whatever the contraction mode, on the femoral nerve at a constant 50° knee flexion (0° = full extension). Concentric, eccentric (both at 20°/s velocity), and isometric voluntary activation levels were then calculated. The mean activation levels during maximal eccentric and maximal concentric contractions were 88.3 and 89.7%, respectively, and were significantly lower ( P &lt; 0.05) with respe…

AdultMalePhysiologyRestEccentric contractionsIsometric exerciseConcentricMuscular ContractionsIsometric ContractionPhysiology (medical)HumansMedicineEccentricKneeMuscle SkeletalLegbusiness.industryTwitch interpolationAnatomyElectric StimulationTorquemedicine.symptomMuscle groupbusinessMuscle ContractionMuscle contraction
researchProduct

Intermuscular force transmission between human plantarflexor muscles in vivo.

2010

The exact mechanical function of synergist muscles within a human limb in vivo is not well described. Recent studies indicate the existence of a mechanical interaction between muscle actuators that may have functional significance and further play a role for injury mechanisms. The purpose of the present study was to investigate if intermuscular force transmission occurs within and between human plantarflexor muscles in vivo. Seven subjects performed four types of either active contractile tasks or passive joint manipulations: passive knee extension, voluntary isometric plantarflexion, voluntary isometric hallux flexion, passive hallux extension, and selective percutaneous stimulation of th…

AdultMalePhysiologyStimulationIsometric exerciseElectromyographyIn vivoPhysiology (medical)Isometric ContractionmedicineHumansDisplacement (orthopedic surgery)Muscle StrengthMuscle SkeletalUltrasonographymedicine.diagnostic_testArthrometry Articularbusiness.industryElectromyographyAnatomyElectric StimulationTendonBiomechanical Phenomenamedicine.anatomical_structureFunctional significanceUltrasonographybusinessJournal of applied physiology (Bethesda, Md. : 1985)
researchProduct