Search results for "Isotope dilution"

showing 10 items of 48 documents

Buchbesprechung: Guidelines for Achieving High Accuracy in Isotope Dilution Mass Spectrometry (IDMS) Herausgegeben von Mike Sargent, Chris Harrington…

2003

ChromatographyChemistryAnalytical chemistryGeneral MedicineIsotope dilutionAngewandte Chemie
researchProduct

Accurate determination of element species by on-line coupling of chromatographic systems with ICP-MS using isotope dilution technique

1998

Abstract The instrumental design for coupling different liquid chromatographic systems such as ion, reversed phase, and size exclusion chromatography as well as capillary gas chromatography, with ICP-MS for the determination of element species is described. For accurate analyses obtaining ‘real time’ concentrations of chromatographic peaks, the isotope dilution mass spectrometric (IDMS) technique is applied. Two different spiking modes are possible, one using species-specific and another one using species-unspecific spike solutions of isotope-enriched labelled compounds. The species-specific mode is only possible for element species well defined in their structure and composition, for examp…

ChromatographyChemistrySize-exclusion chromatographyAnalytical chemistryIsotope dilutionMass spectrometryHigh-performance liquid chromatographyAtomic and Molecular Physics and OpticsAnalytical ChemistryGel permeation chromatographychemistry.chemical_compoundGas chromatographyInstrumentationInductively coupled plasma mass spectrometrySpectroscopyIodateSpectrochimica Acta Part B: Atomic Spectroscopy
researchProduct

Isotope-dilution ICP-MS for trace element determination and speciation: from a reference method to a routine method?

2003

This critical review discusses the conditions under which inductively coupled plasma-isotope dilution mass spectrometry (ICP-IDMS) is suitable as a routine method for trace element and element-speciation analysis. It can, in general, be concluded that ICP-IDMS has high potential for routine analysis of trace elements if the accuracy of results is of predominant analytical importance. Hyphenated techniques with ICP-IDMS suffer both from lack of commercially available isotope-labeled spike compounds for species-specific isotope dilution and from the more complicated system set-up required for species-unspecific ICP-IDMS analysis. Coupling of gas or liquid chromatography with species-specific …

ChromatographyChemistryVaporizationExtraction (chemistry)Analytical chemistryTrace elementSample preparationIsotope dilutionMass spectrometryBiochemistryInductively coupled plasma mass spectrometryAnalytical ChemistryDilutionAnalytical and bioanalytical chemistry
researchProduct

Development of a species-unspecific isotope dilution GC-ICPMS method for possible routine quantification of sulfur species in petroleum products.

2008

Inductively coupled plasma mass spectrometry (ICPMS) hyphenated with capillary gas chromatography was applied for sulfur multispecies determination in petroleum products by species-unspecific isotope dilution mass spectrometry (IDMS). To guarantee a stable and continuous addition of the spike into the GC-ICPMS system, a special dosing unit was designed and synthesis of a (34)S-labeled dimethyldisulfide spike from (34)S-enriched elemental sulfur in the milligram range was developed. The sample was mixed with an internal standard for spike mass flow calibration. From the mass flow chromatogram obtained by species-unspecific GC-ICP-IDMS, determination of all separated sulfur species and of the…

Chromatographybusiness.industrychemistry.chemical_elementIsotope dilutionMass spectrometrySulfurAnalytical ChemistryMatrix (chemical analysis)Petroleum productchemistryIon trapGas chromatographybusinessInductively coupled plasma mass spectrometryAnalytical chemistry
researchProduct

Determination of acrylamide in coffee and chocolate by pressurised fluid extraction and liquid chromatography-tandem mass spectrometry.

2007

A selective and sensitive procedure has been developed and validated for the determination of acrylamide in difficult matrices, such as coffee and chocolate. The proposed method includes pressurised fluid extraction (PFE) with acetonitrile, florisil clean-up purification inside the PFE extraction cell and detection by liquid chromatography (LC) coupled to atmospheric pressure ionisation in positive mode tandem mass spectrometry (APCI-MS-MS). Comparison of ionisation sources (atmospheric pressure chemical ionisation (APCI), atmospheric pressure photoionization (APPI) and the combined APCI/APPI) and clean-up procedures were carried out to improve the analytical signal. The main parameters aff…

Detection limitAcrylamideCacaoChromatographyAtmospheric pressureChemistryHealth Toxicology and MutagenesisExtraction (chemistry)Public Health Environmental and Occupational HealthAnalytical chemistryAtmospheric-pressure chemical ionizationGeneral ChemistryIsotope dilutionToxicologyMass spectrometryTandem mass spectrometryCoffeeChemistry (miscellaneous)Liquid chromatography–mass spectrometrySpainTandem Mass SpectrometryFood ScienceChromatography LiquidFood additives and contaminants
researchProduct

Cr(III)/Cr(VI) speciation in aerosol particles by extractive separation and thermal ionization isotope dilution mass spectrometry

1997

An isotope dilution mass spectrometric (IDMS) method, using the formation of positive thermal ions, was developed for Cr(III) and Cr(VI) speciation in aerosol particles. Cr(III) and Cr(VI) spike species, enriched in 53Cr, were applied for the isotope dilution step. After leaching of filter collected aerosol samples by an alkaline solution at pH 13, species separation was carried out by extraction with a liquid anion exchanger in methyl isobutyl ketone. Cr(VI) in the organic phase was re-extracted into an ammoniacal solution and chromium was then isolated from both fractions of species by electrodeposition. Detection limits of 30 pg/m3 for Cr(III) and of 8 pg/m3 for Cr(VI) were achieved in a…

Detection limitChemistryAnalytical chemistrychemistry.chemical_elementIsotope dilutionMass spectrometryBiochemistryAerosolMethyl isobutyl ketonechemistry.chemical_compoundChromiummedia_common.cataloged_instanceLeaching (metallurgy)European unionmedia_commonFresenius' Journal of Analytical Chemistry
researchProduct

Determination of uranium in tap water by ICP-MS

2000

A fast and accurate procedure has been developed for the determination of uranium at microg L(-1) level in tap and mineral water. The method is based on the direct introduction of samples, without any chemical pre-treatment, into an inductively coupled plasma mass spectrometer (ICP-MS). Uranium was determined at the mass number 238 using Rh as internal standard. The method provides a limit of detection of 2 ng L(-1) and a good repeatability with relative standard deviation values (RSD) about 3% for five independent analyses of samples containing 73 microg L(-1) of uranium. Recovery percentage values found for the determination of uranium in spiked natural samples varied between 91% and 106%…

Detection limitChromatographyChemistryAnalytical chemistryReproducibility of Resultschemistry.chemical_elementRepeatabilityIsotope dilutionUraniumSensitivity and SpecificityBiochemistryMass SpectrometryMoroccoMineral waterTap waterMetalsSpainWater SupplyUraniumInductively coupled plasmaInductively coupled plasma mass spectrometryFresenius' Journal of Analytical Chemistry
researchProduct

Determination of ruthenium in photographic emulsions - Development and comparison of different sample treatments and mass spectrometric methods

1999

Different sample treatment procedures were combined with inductively coupled plasma mass spectrometry (ICP-MS) and negative thermal ionisation mass spectrometry (NTI-MS) for the determination of ruthenium traces in photographic emulsions. Dissolution of the samples in concentrated ammonia solution was used in connection with ICP-MS by external calibration, which has the advantage of a simple sample preparation technique but introduces high amounts of the silver matrix into the mass spectrometer. On the other hand, isotope dilution mass spectrometry (IDMS) with an enriched 99Ru spike solution was applied for ICP-MS and NTI-MS measurements, respectively, in connection with a significant reduc…

Detection limitChromatographyChemistryAnalytical chemistrychemistry.chemical_elementIsotope dilutionMass spectrometryBiochemistryRuthenium/dk/atira/pure/sustainabledevelopmentgoals/clean_water_and_sanitationMatrix (chemical analysis)Sample preparationPhotographic emulsionSDG 6 - Clean Water and SanitationInductively coupled plasma mass spectrometry
researchProduct

Bromide/bromate speciation by NTI-IDMS and ICP-MS coupled with ion exchange chromatography

1997

Two different mass spectrometric methods, negative thermal ionization isotope dilution mass spectrometry (NTI-IDMS) and inductively coupled plasma mass spectrometry (ICP-MS), off-line and on-line coupled with anion exchange chromatography, have been developed for simultaneous bromide and bromate determinations in water samples. The detection limits of these methods are in the range of 0.03–0.09 μg/L using a 50 mL sample.The results are independent of the content of other anions, which could be demonstrated by the analyses of six mineral waters containing chloride and sulfate of up to 160 mg/L and 1500 mg/L, respectively. Bromide has been analyzed by the NTI-IDMS method in the range of 10–50…

Detection limitChromatographyIon chromatographyIsotope dilutionBromateBiochemistrychemistry.chemical_compoundchemistryBromideStandard additionmedia_common.cataloged_instanceEuropean unionInductively coupled plasma mass spectrometrymedia_commonFresenius' Journal of Analytical Chemistry
researchProduct

Development of an ICP−IDMS Method for Dissolved Organic Carbon Determinations and Its Application to Chromatographic Fractions of Heavy Metal Complex…

1998

A sensitive and fast method for direct determinations of dissolved organic carbon (DOC) in bulk samples and in chromatographically separated fractions by inductively coupled plasma isotope dilution mass spectrometry (ICP−IDMS) is developed. A 13C-enriched spike solution of benzoic acid is used for the isotope dilution step. Equal ionization efficiencies are obtained for carbon, independent of the type and molecular weight of the dissolved organic substance, which is the most important precondition for DOC determinations by ICP−IDMS. The detection limits achieved are 0.3 mg L-1 for bulk analyses and 7 × 10-4 μg s-1 for transient signals of chromatographic peaks. The results for different wat…

Detection limitChromatographyIsotopeChemistryAnalytical chemistrychemistry.chemical_elementIsotope dilutionMass spectrometryAnalytical Chemistrychemistry.chemical_compoundDissolved organic carbonInductively coupled plasmaCarbonBenzoic acidAnalytical Chemistry
researchProduct