Search results for "Joint"
showing 10 items of 1472 documents
Muscle deficits persist after unilateral knee replacement and have implications for rehabilitation.
2009
BackgroundKnee joint arthritis causes pain, decreased range of motion, and mobility limitation. Knee replacement reduces pain effectively. However, people with knee replacement have decreases in muscle strength (“force-generating capacity”) of the involved leg and difficulties with walking and other physical activities.Objective and DesignThe aim of this cross-sectional study was to determine the extent of deficits in knee extensor and flexor muscle torque and power (ability to perform work over time) and in the extensor muscle cross-sectional area (CSA) after knee joint replacement. In addition, the association of lower-leg muscle deficits with mobility limitations was investigated.Methods…
Preliminary Experience with a Novel System of Facet Fixation to Treat Patients with Lumbar Degenerative Disease. A New Perspective in Minimally Invas…
2017
Purpose We report our experience with a novel surgical device for the treatment of lumbar degenerative microinstability. Facet Wedge (DePuy Synthes, Raynham, Massachusetts, United States) is a novel technique of intra-articular lumbar facet fixation that provides a minimally invasive alternative to standard posterior fixation. Materials and Methods From November 2014 to July 2015, 38 patients underwent single-level Facet Wedge implantation. The main surgical indications included herniated disk (18 patients), spinal canal and foraminal stenosis (14 patients), and Meyerding grade I degenerative spondylolisthesis (6 patients). All the patients showed radiologic signs of microinstability: hype…
Leg and joint stiffness in human hopping
2010
The present study investigated the regulation of leg and joint stiffness in hopping at different intensity levels. Eight male subjects performed bilateral hopping at various intensity levels that were determined by peak vertical ground reaction force (GRF). In addition to the GRF, the measurements included hopping kinematics and electromyography (EMG) of selected leg muscles. While the leg and ankle joint stiffness remained invariant, the knee joint stiffness increased significantly (P<0.01) with the hopping intensity. EMG analysis revealed a significant increase in averaged EMG for all the measured muscles before and during the early phase of ground contact (P<0.05-0.001) with increasing h…
Effects of muscle activation on shear between human soleus and gastrocnemius muscles
2015
Lateral connections between muscles provide pathways for myofascial force transmission. To elucidate whether these pathways have functional roles in vivo, we examined whether activation could alter the shear between the soleus (SOL) and lateral gastrocnemius (LG) muscles. We hypothesized that selective activation of LG would decrease the stretch-induced shear between LG and SOL. Eleven volunteers underwent a series of knee joint manipulations where plantar flexion force, LG, and SOL muscle fascicle lengths and relative displacement of aponeuroses between the muscles were obtained. Data during a passive full range of motion were recorded, followed by 20° knee extension stretches in both pass…
Iliosacral Screw Osteosynthesis
2017
Fragility fractures of the anterior pelvic ring are very often combined with fractures of the posterior pelvic ring. The large majority of the posterior fractures is situated in the sacral ala. Non-operative therapy may be cumbersome in patients with a combination of an anterior with a posterior pelvic ring fracture. Any surgical therapy should be as less invasive as possible. Iliosacral screw fixation is a minimal invasive technique. Variations of the upper sacral anatomy make optimal iliosacral screw placement challenging. The vestibule or isthmus is the narrowest part of the bony corridor from the lateral ilium to the S1 sacral body. It always points towards anterior and superior. The wh…
Breaststroke swimmer's knee
1980
The cause of the breaststroke swimmer's knee with medial pain of the knee joint has not been clearly identified. Breaststroke swimmers with knee pain were, therefore, examined arthros copically. None showed any other disorders of their knees than medial synovitis in seven of nine swimmers. Since structural abnormalities could be ruled out, biomechanical analyses utiliz ing cinematographic techniques were used to study patients swimming in a special flume with the speed set at 90% of their best competitive performance. The results indicate that the extension and flexion and also in some cases the hip abduction and adduction movements of the whip kick were performed with high peak angular ve…
Das Kiefergelenk bei entzündlichen, degenerativen und weichteilrheumatischen Erkrankungen
1991
Temporomandibular joint affections in rheumatic disease are described. They were seen in inflamed joint diseases, mostly in rheumatoid arthritis, and less so in juvenile rheumatoid arthritis, psoriatic arthritis, Reiter’s syndrome, ankylosing spondylitis, and collagen vascular disease.
Numerical experimental analysis of hybrid double lap aluminum-CFRP joints
2015
Abstract Due to their reliability and ease of assembly, both the adhesively bonded and the mechanical joints are commonly used in different fields of modern industrial design and manufacturing, to joint composite materials or composites with metals. As it is well known, adhesively bonded joints are characterized by high stiffness and good fatigue life, although delamination phenomena localized near the free edges may limit their use, especially for applications where corrosive environments and/or moisture can lead to premature failure of the bonding. In these cases, a possible alternative is given by the well-known mechanical joints. On the contrary, these last joints (bolted, riveted) requ…
The Shoulder Girdle
2000
The shoulder girdle is an anatomically complex structure consisting of the scapula, clavicula, proximal humerus, and their articular connections. The wide range of motion is provided by the glenohumeral joint and the two shoulder girdle joints, the acromioclavicular and sternoclavicular joints.
Use of accelerometers and gyros for hip and knee angle estimation
2013
In this paper a wearable sensor system, consisting of accelerometers and gyros, has been studied to estimate hip and knee angles. The proposed algorithm, developed in order to avoid the error accumulation due to gyroscopes drift, has been tested on angle measurement of the hip and knee of a commercial device for assisted gait. The results have shown a good accuracy of the angles estimation, also in high angle rate movement