Search results for "KNEE"
showing 10 items of 527 documents
Risk of surgical site infections following hip and knee arthroplasty: Results of the ischia-gisio study
2017
Surgical Site Infection (SSI) is one of the major complications following insertion of hip or knee prosthesis. The aim of the present study was to describe rates of SSIs and associated risk factors during hip and knee prosthesis procedures in Italian hospitals. METHODS: Italian hospitals were invited to join the ISChIA (Surgical Site Infections in Arthroplasty Surgery) project and participated in the study on a voluntary basis. SSI surveillance was performed according to the Hospitals in Europe Link for Infection Control through Surveillance (HELICS) -SSI protocol. The study population consisted of all patients who had a prosthetic knee or hip joint replacement between March 2010 and Februa…
Lower strength of the human posterior patellar tendon seems unrelated to mature collagen cross-linking and fibril morphology
2009
The human patellar tendon is frequently affected by tendinopathy, but the etiology of the condition is not established, although differential loading of the anterior and posterior tendon may be associated with the condition. We hypothesized that changes in fibril morphology and collagen cross-linking would parallel differences in material strength between the anterior and posterior tendon. Tendon fascicles were obtained from elective ACL surgery patients and tested micromechanically. Transmission electron microscopy was used to assess fibril morphology, and collagen cross-linking was determined by HPLC and calorimetry. Anterior fascicles were markedly stronger (peak stress: 54.3 ± 21.2 vs.…
Evaluation of regional haemodynamics and alterations of vascular wall of the lower limbs in hypertensive subjects
1995
This study was designed to analyse the relationship between arterial hypertension and changes in arterial blood flow and vascular wall damage of the lower limbs in hypertensive patients with various degrees of hypertension. Six hundred and fifty-four hypertensive patients (421 males and 233 females) aged 35 to 70 years and 88 healthy subjects (63 males and 25 females) aged 39 to 60 years were studied. Strain-gauge plethysmography of the lower limbs was used to calculate arterial calf blood flow (RF), arterial calf blood flow after post-ischaemic hyperaemia (PF), basal and minimal vascular resistances (BVR and MVR), time to reach peak flow (tPF), time until 50% reduction of peak flow (tT1/2)…
Biomechanical loading in the triple jump
2000
The triple jump is a demanding field event in which a jumper must tolerate extremely high impact forces while maintaining high horizontal speed. The present study was designed to clarify the mechanical loading characteristics and the role of neuromuscular function in the triple jump. Seven national triple jumpers (4 males, 3 females) volunteered to perform 3-6 jumps. The mean best performances were 14.32+/-0.45 m and 11.90+/-0.28 m for males and females, respectively. The three longest triple jumps for each jumper were selected for final analysis. The mean contact times were 0.139 s (hop), 0.157 s (step) and 0.177 s (jump). The largest ground reaction forces were observed in the step (15.2 …
Modular Control of Pointing beyond Arm's Length
2009
Hand reaching and bipedal equilibrium are two important functions of the human motor behavior. However, how the brain plans goal-oriented actions combining target reaching with equilibrium regulation is not yet clearly understood. An important question is whether postural control and reaching are integrated in one single module or controlled separately. Here, we show that postural control and reaching motor commands are processed by means of a modular and flexible organization. Principal component and correlation analyses between pairs of angles were used to extract global and local coupling during a whole-body pointing beyond arm's length. A low-dimensional organization of the redundant ki…
Human isometric force production and electromyogram activity of knee extensor muscles in water and on dry land.
1999
This study was designed to determine trial-to-trial and day-to-day reproducibility of isometric force and electromyogram activity (EMG) of the knee extensor muscles in water and on dry land as well as to make comparisons between the two training conditions in muscle activity and force production. A group of 20 healthy subjects (12 women and 8 men) were tested three times over 2 weeks. A measurement session consisted of recordings of maximal and submaximal isometric knee extension force with simultaneous recording of surface EMG from the vastus medialis, vastus lateralis and biceps femoris muscles. To ensure identical measurement conditions the same patient elevator chair was used in both th…
Electromechanical behaviour of human muscles in vertical jumps
1982
The relationships of muscle structure to the potentiation of myoelectrical activity and to the use of prestretching in five lower limb muscles were studied in different vertical jumping conditions. The subjects for the study were six male students, divided according to the muscle fiber distribution in m. vastus lateralis into “fast” and “slow” groups. The subjects performed vertical jumps (1) from a static squatting position (SJ), (2) with a preliminary counter movement (CMJ) and (3) after dropping (DJ) from five different heights. Myoelectrical (EMG) activity was recorded from mm. gluteus maximus, vastus lateralis, vastus medialis, rectus femoris and gastrocnemius in each jumping condition…
Effects of muscle – tendon length on joint moment and power during sprint starts
2005
The aim of this study was to examine the effects of muscle-tendon length on joint moment and power during maximal sprint starts. Nine male sprinters performed maximal sprint starts from the blocks that were adjusted either to 40 degrees or 65 degrees to the horizontal. Ground reaction forces were recorded at 833 Hz using a force platform and kinematic data were recorded at 200 Hz with a film camera. Joint moments and powers were analysed using kinematic and kinetic data. Muscle - tendon lengths of the medial gastrocnemius, soleus, vastus medialis, rectus femoris and biceps femoris were calculated from the set position to the end of the first single leg contact. The results indicated that bl…
Effects of different electrical stimulation currents and phase durations on submaximal and maximum torque, efficiency, and discomfort: a randomized c…
2021
Abstract Background Neuromuscular electrical stimulation (NMES) is an important therapeutic tool for rehabilitation. However, best stimulation parameters remain to be determined. Objective To determine the influence of different electrical stimulation currents and phase durations on torque, efficiency, and discomfort. Methods Using a cross-over design, kHz frequency alternating currents (KFAC) and pulsed currents (PC) with narrow (200 µs) or wide (500 µs) phase durations were randomly applied on knee extensor muscles of healthy participants with a minimum of seven days between sessions. The NMES-evoked torque, NMES-efficiency, and discomfort (visual 0−10 cm analogue scale) were measured for…
Contribution of the tendinous tissue to force enhancement during stretch–shortening cycle exercise depends on the prestretch and concentric phase int…
2005
When the prestretch intensity and concentric work are increased in stretch-shortening cycle (SSC) exercises, the utilization of the elastic energy can increase during the concentric phase. In order to further understand this process during SSC exercises, the interaction between fascicle-tendinous tissues (TT) of the vastus lateralis (VL) muscle was examined under different prestretch and rebound intensity drop jumps. Ten male subjects participated in the study. Direct VL fascicle lengths (N = 10) and in vivo patellar tendon force (N = 1) were measured together with the electromyographic (EMG) activity of VL during the trials. With increasing drop height but the same rebound height condition…