2019

Purpose Myopia is increasing worldwide and possibly linked to education. In this study, we analyse the association of myopia and education in the U.S. and investigate its age-dependency. Methods We conducted a secondary data analysis using the public use files from the cross-sectional study National Health and Nutrition Examination Survey of the period from 1999 to 2008. 19,756 participants aged 20 to 85 years were included with data on education and ophthalmic parameters (distance visual acuity, objective refraction and keratometry). Spherical equivalent, astigmatism, corneal power and corneal astigmatism were evaluated for an association with education using linear regression analysis wit…

0301 basic medicineUnivariate analysisMultidisciplinaryVisual acuitygenetic structuresKeratometerNational Health and Nutrition Examination SurveyHigher educationbusiness.industryCross-sectional studySecondary dataAstigmatismmedicine.diseaseeye diseaseslaw.invention03 medical and health sciences030104 developmental biology0302 clinical medicinelaw030221 ophthalmology & optometryMedicineOptometrymedicine.symptombusinessPLOS ONE
researchProduct

Repeatability assessment of biometric measurements with different refractive states and age using a swept-source biometer

2018

Background We aim to assess if refractive error or age may influence the repeatability of measurements using a swept-source biometer. Methods A total of 61 subjects were evaluated with IOLMaster 700 acquiring measurements of axial length (AL), central corneal thickness (CCT), white-to-white distance (WTW), anterior aqueous depth (AQD), lens thickness (LT), and keratometry (K) readings. Repeatability was evaluated classifying the sample according to the refractive state and age by the calculation of the within-subject standard deviation (Sw), coefficient of repeatability, and intraclass correlation coefficient. Results Very similar Sw was acquired among groups for AL, CCT, and WTW. Differenc…

AdultMaleAgingRefractive errormedicine.medical_specialtyBiometryIntraclass correlationBiomedical Engineering030204 cardiovascular system & hematologyAstigmatismStandard deviationlaw.inventionYoung Adult03 medical and health sciences0302 clinical medicineLens thicknessAge groupslawOphthalmologyLens CrystallinemedicineHumansMathematicsKeratometerAge FactorsReproducibility of ResultsGeneral MedicineRepeatabilityMiddle AgedRefractive Errorsmedicine.diseaseAxial Length EyeFemaleSurgeryTomography Optical Coherence030217 neurology & neurosurgeryExpert Review of Medical Devices
researchProduct

Repeatability of whole-cornea measurements using an anterior segment imaging device based on OCT and Placido-disk

2017

Current advances in refractive surgery require high accuracy of corneal measurements. We aim to evaluate the repeatability of topographic measurements using an integrated Placido disk - OCT device.Thirty right eyes of thirty healthy and young subjects were included. The topographic parameters of simulated keratometry, asphericity, minimum pachymetry, white-to-white distance, spherical aberration and corneal elevation were studied. Three measurements were taken by the same observer using the Visante omni device. The coefficient of repeatability (CoR), coefficient of variation (CoV) and intraclass correlation coefficient (ICC) were calculated to assess the repeatability. The Bland-Altman grap…

AdultMaleCorneal PachymetryIntraclass correlationmedicine.medical_treatmentCoefficient of variationBiomedical Engineeringlaw.inventionCorneaYoung Adult03 medical and health sciences0302 clinical medicineOpticslawRefractive surgerymedicineHumansCorneal pachymetryMathematicsKeratometermedicine.diagnostic_testbusiness.industryCorneal TopographyReproducibility of ResultsGeneral MedicineRepeatabilityCorneal topographySpherical aberration030221 ophthalmology & optometryFemaleSurgerybusinessTomography Optical Coherence030217 neurology & neurosurgeryBiomedical engineeringExpert Review of Medical Devices
researchProduct

Corneoscleral contact lenses for visual rehabilitation after keratoplasty surgery.

2019

Abstract Purpose To report the use of corneoscleral lenses (CSL) in keratoconus patients who were unsatisfied with their visual outcomes after keratoplasty surgery. Methods Eleven consecutive cases with unsatisfactory vision with spectacles, due to irregular astigmatism, preferred to try CSL before SL due to handling or economic issues. An eye examination included refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count (ECC) and evaluation of corneal biomechanical parameters (corneal resistance factor, CRF; corneal hysteresis, CH; corneal-compensated intraocular pressure, IOPcc). The fitting process…

AdultMaleKeratoconusIntraocular pressuremedicine.medical_specialtyVisual acuitygenetic structuresContact LensesVisual rehabilitationKeratoconusRefraction Ocularlaw.inventionCorneal hysteresisCorneal Transplantation03 medical and health sciences0302 clinical medicinelawmedicineHumansAgedRetrospective StudiesAged 80 and overKeratometerIrregular astigmatismmedicine.diagnostic_testbusiness.industryAstigmatismCorneal TopographyGeneral MedicineMiddle Agedmedicine.diseaseeye diseasesSurgeryOphthalmologyEye examination030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryKeratoplasty PenetratingOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Assessment of corneal morphological changes induced by the use of daily disposable contact lenses.

2015

To assess the effect of different disposable soft contact lenses upon corneal thickness, and upon anterior and posterior corneal curvatures using a dual-Scheimpflug imaging based device.Twenty-eight young, healthy subjects wore four different types of daily disposable soft contact lenses on four different days: Dailies Total1, Proclear 1 Day, Clariti 1-Day and 1-Day Acuvue Moist. The lenses had different material and water content. Pachymetry maps and keratometry values were obtained using the Galilei G4 twice a day: one before putting the lens on and one after an eight-hour period of contact-lens wear. Measurements were also recorded without any contact lenses being worn during a day.Clari…

AdultMaleVisual Acuitylaw.inventionCorneaYoung AdultlawMyopiaMedicineHumansDisposable EquipmentKeratometerCorneal curvaturebusiness.industryHealthy subjectsCorneal TopographyGeneral MedicineEquipment DesignContact Lenses Hydrophiliceye diseasesContact lensLens (optics)OphthalmologyOptometryDaily disposableFemalesense organsThickeningbusinessOptometryFollow-Up StudiesContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Comparison of Immersion Ultrasound, Partial Coherence Interferometry, and Low Coherence Reflectometry for Ocular Biometry in Cataract Patients

2011

PURPOSE: To compare ocular biometry parameters measured with immersion ultrasound, partial coherence interferometry, and low coherence reflectometry in cataract patients. METHODS: Measurements of axial length and anterior chamber depth were analyzed and compared using immersion ultrasound, partial coherence interferometry, and low coherence reflectometry. Keratometry (K), flattest axis, and white-to-white measurements were compared between partial coherence interferometry and low coherence reflectometry. Seventy-eight cataract (LOCS II range: 1 to 3) eyes of 45 patients aged between 42 and 90 years were evaluated. A subanalysis as a function of cataract degree was done for axial length and…

AdultMalemedicine.medical_specialtyBiometryMaterials scienceAnterior ChamberDiagnostic Techniques OphthalmologicalCataractlaw.inventionOpticslawOphthalmologymedicineHumansBody Weights and MeasuresReflectometryAgedUltrasonographyAged 80 and overKeratometerbusiness.industryUltrasoundAnova testAxial lengthMiddle AgedAxial Length EyeOphthalmologyInterferometryInterferometryPartial coherence interferometryFemaleSurgeryUltrasonographybusinessJournal of Refractive Surgery
researchProduct

Early clinical outcomes after small incision lenticule extraction surgery (SMILE)

2018

Abstract Purpose Dry eye is known to impact on clinical outcomes after laser vision correction and the use of a newer ‘all femtosecond laser’ surgical approach may be associated with less impact on the ocular surface post-operatively. The purpose of this study was to evaluate the early clinical outcomes and tear instability after the first small incision lenticule extraction (SMILE) cases undertaken by three surgeons at a single site in the UK. Methods Retrospective audit. Seventy-one eyes of 37 patients underwent SMILE surgery using the Zeiss VisuMax laser system (Carl Zeiss Meditec, Germany). Uncorrected and corrected distance visual acuity, spherical equivalent refraction, fluorescein en…

AdultMalemedicine.medical_specialtyVisual acuityDistance visual acuitygenetic structuresCorneal Surgery LaserCorneal StromaVisual AcuityRefraction Ocularlaw.invention03 medical and health sciences0302 clinical medicineSingle sitelawOphthalmologyMyopiamedicineHumansSmall incision lenticule extractionSmile surgeryRetrospective StudiesSurgical approachKeratometerbusiness.industryCorneal TopographyGeneral Medicineeye diseasesSurgeryOphthalmologyTears030221 ophthalmology & optometryFemaleLasers Excimersense organsmedicine.symptombusinessOcular surface030217 neurology & neurosurgeryOptometry
researchProduct

Influence of optic quality on contrast sensitivity and visual acuity in eyes with a rigid or flexible phakic intraocular lens

2009

Purpose To determine whether the difference in optic quality between 2 types of phakic intraocular lenses (pIOLs) affects visual quality. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Before implantation of a pIOL for myopia, all eyes had an examination including corrected (CDVA) and uncorrected (UDVA) distance visual acuity testing, corneal endothelial cell count (ECC), and intraocular pressure (IOP) measurement. The postoperative outcomes, determined at least 1 year after surgery, were CDVA; UDVA; contrast sensitivity function under photopic, mesopic, and mesopic with glare conditions; ECC; IOP; keratometry (Scheimpflug photography); and total ocular aberratio…

AdultPhakic Intraocular LensesIntraocular pressuremedicine.medical_specialtyVisual acuityOptical Phenomenagenetic structuresAnterior ChamberMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityCell CountIntraocular lensProsthesis DesignPhakic intraocular lensGlarelaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyMyopiamedicineHumansContrast (vision)Intraocular Pressuremedia_commonKeratometerbusiness.industryEndothelium Cornealeye diseasesSensory SystemsOphthalmologyOptometrySurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Ocular biometry with swept-source optical coherence tomography

2020

This study aimed to summarize the outcomes reported when swept-source optical coherence tomography (SS-OCT) is used for ocular biometry. A literature search was performed to identify publications reporting clinical outcomes of patients measured with commercial SS-OCT. Twenty-nine studies were included in this review. A comprehensive analysis of the available data was performed, focusing on parameters used for intraocular lens (IOL) power calculation in cataract surgery, including keratometry, central corneal thickness, white-to-white distance, anterior chamber depth, lens thickness, axial length, IOL power, and pupil diameter. Different metrics for repeatability, reproducibility, and agreem…

Biometrygenetic structuresAnterior Chambermedicine.medical_treatmentIntraocular lensCataractlaw.invention03 medical and health sciences0302 clinical medicineOptical coherence tomographyLens thicknesslawHumansMedicineLenses IntraocularReproducibilitymedicine.diagnostic_testKeratometerbusiness.industryReproducibility of ResultsGold standard (test)RepeatabilityCataract surgeryeye diseasesSensory SystemsAxial Length EyeOphthalmology030221 ophthalmology & optometryOptometrySurgerysense organsbusinessTomography Optical Coherence030217 neurology & neurosurgeryJournal of Cataract and Refractive Surgery
researchProduct

Evaluation of 6 biometers based on different optical technologies

2021

This study shows that optical biometers based on different technologies provide repeatable measurements for different ocular parameters and, when compared, statistically significant differences between them were found when measuring most parameters.

Biometrygenetic structuresKeratometerAnterior ChamberCoefficient of variationReproducibility of ResultsArticlesRepeatabilityeye diseasesSensory Systemslaw.inventionCorneaAxial Length EyeOphthalmologylawStatisticsHumansSurgerysense organsProspective StudiesTomography Optical CoherenceMathematicsJournal of Cataract and Refractive Surgery
researchProduct