Search results for "Kerma"
showing 10 items of 46 documents
The 4th international comparison on EPR dosimetry with tooth enamel
2011
This paper presents the results of the 4th International Comparison of in vitro electron paramagnetic resonance dosimetry with tooth enamel, where the performance parameters of tooth enamel dosimetry methods were compared among sixteen laboratories from all over the world. The participating laboratories were asked to determine a calibration curve with a set of tooth enamel powder samples provided by the organizers. Nine molar teeth extracted following medical indication from German donors and collected between 1997 and 2007 were prepared and irradiated at the Helmholtz Zentrum Munchen. Five out of six samples were irradiated at 0.1, 0.2, 0.5, 1.0 and 1.5 Gy air kerma; and one unirradiated s…
Monte Carlo evaluation of kerma in an HDR brachytherapy bunker
2004
In recent years, the use of high dose rate (HDR) after-loader machines has greatly increased due to the shift from traditional Cs-137/Ir-192 low dose rate (LDR) to HDR brachytherapy. The method used to calculate the required concrete and, where appropriate, lead shielding in the door is based on analytical methods provided by documents published by the ICRP, the IAEA and the NCRP. The purpose of this study is to perform a more realistic kerma evaluation at the entrance maze door of an HDR bunker using the Monte Carlo code GEANT4. The Monte Carlo results were validated experimentally. The spectrum at the maze entrance door, obtained with Monte Carlo, has an average energy of about 110 keV, m…
Seasonal variation of air kerma rate in Sicily.
2007
Thermoluminescence dosimetry has been used to measure air kerma in 29 sites in Sicily. Four three month measurement campaigns have been carried out in order to assess seasonal variations. Average annual values between 20 and 90 nGy h(-1), after cosmic background subtraction, are reported. Average annual values are strongly dependent on site lithology, and we find that winter data are generally the highest, while spring and autumn rates are generally the lowest with very similar trends in any site. Summer values generally lay in between. Largest seasonal variations are found in sites along the southern coast of the island, probably because of stronger action of winds affecting radon, along w…
Gut microbiota disturbance during antibiotic therapy: a multi-omic approach
2014
It is known that the gastrointestinal tract (GIT) microbiota responds to different antibiotics in different ways and that while some antibiotics do not induce disturbances of the community, others drastically influence the richness, diversity, and prevalence of bacterial taxa. However, the metabolic consequences thereof, independent of the degree of the community shifts, are not clearly understood. In a recent article, we used an integrative OMICS approach to provide new insights into the metabolic shifts caused by antibiotic disturbance. The study presented here further suggests that specific bacterial lineage blooms occurring at defined stages of antibiotic intervention are mostly associa…
Reducing Patient Radiation Dose With Image Noise Reduction Technology in Transcatheter Aortic Valve Procedures
2015
X-ray radiation exposure is of great concern for patients undergoing structural heart interventions. In addition, a larger group of medical staff is required and exposed to radiation compared with percutaneous coronary interventions. This study aimed at quantifying radiation dose reduction with implementation of specific image noise reduction technology (NRT) in transcatheter aortic valve implantation (TAVI) procedures. We retrospectively analyzed 104 consecutive patients with TAVI procedures, 52 patients before and 52 after optimization of x-ray radiation chain, and implementation of NRT. Patients with 1-step TAVI and complex coronary intervention, or complex TAVI procedures, were excluded…
Design and evaluation of a HDR skin applicator with flattening filter
2008
The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, made of tungsten, aim to flatten the heterogeneous dose distribution obtained with the Leipzig applicators. (ii) To estimate the dose rate distributions for these Leipzig+filter applicators by means of the Monte Carlo (MC) method. (iii) To experimentally verify these distributions for prototypes of these new applicators, and (iv) to obtain the correspondence factors to measure t…
Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions
2016
Purpose: The aims of this study were (i) to design a new high-dose-rate (HDR) brachytherapy applicator for treating surface lesions with planning target volumes larger than 3 cm in diameter and up to 5 cm in size, using the microSelectron-HDR or Flexitron afterloader (Elekta Brachytherapy) with a 192Ir source; (ii) to calculate by means of the Monte Carlo(MC) method the dose distribution for the new applicator when it is placed against a water phantom; and (iii) to validate experimentally the dose distributions in water. Methods: The penelope2008MC code was used to optimize dwell positions and dwell times. Next, the dose distribution in a water phantom and the leakage dose distribution arou…
Cross-regional view of functional and taxonomic microbiota composition in obesity and post-obesity treatment shows country specific microbial contrib…
2019
This work was supported by CONICYT-Chile through the FONDECYT [n° 3160525] (DM) and by Universidad San Sebastián, and by grants to AM from the Spanish Ministry of Economy and Competitiveness (projects SAF2012-31187, SAF2013-49788-EXP, SAF2015-65878-R), Carlos III Health Institute (Projects PIE14/00045 and AC15/00022), Generalitat Valenciana (Project PrometeoII/2014/065 and Prometeo/2018/A/133), Asociación Española Contra el Cancer (Project AECC 2017-1485) and co-financed by the European Regional Development Fund (ERDF).
A Critical Perspective on the Supplementation of Akkermansia muciniphila: Benefits and Harms
2023
Akkermansia muciniphila is a mucin-degrading bacterium of the intestinal niche, exerting beneficial effects on the host metabolic profile. Accumulating evidence indicated Akkermansia as a promising therapeutic probiotic against metabolic disorders such as obesity, type 2 diabetes and cardiovascular diseases. However, in specific intestinal microenvironments, its excessive enrichment may be not beneficial. Conditions like inflammatory bowel disease (IBD), Salmonella typhimurium infection or post-antibiotic reconstitution may not benefit from Akkermansia supplementation. Furthermore, using Akkermansia in patients with endocrine and gynecological disorders—such as polycystic ovary syndrome (PC…
Air-kerma evaluation at the maze entrance of HDR brachytherapy facilities.
2014
In the absence of procedures for evaluating the design of brachytherapy (BT) facilities for radiation protection purposes, the methodology used for external beam radiotherapy facilities is often adapted. The purpose of this study is to adapt the NCRP 151 methodology for estimating the air-kerma rate at the door in BT facilities. Such methodology was checked against Monte Carlo (MC) techniques using the code Geant4. Five different facility designs were studied for (192)Ir and (60)Co HDR applications to account for several different bunker layouts.For the estimation of the lead thickness needed at the door, the use of transmission data for the real spectra at the door instead of the ones emit…