Search results for "Kerma"

showing 10 items of 46 documents

The 4th international comparison on EPR dosimetry with tooth enamel

2011

This paper presents the results of the 4th International Comparison of in vitro electron paramagnetic resonance dosimetry with tooth enamel, where the performance parameters of tooth enamel dosimetry methods were compared among sixteen laboratories from all over the world. The participating laboratories were asked to determine a calibration curve with a set of tooth enamel powder samples provided by the organizers. Nine molar teeth extracted following medical indication from German donors and collected between 1997 and 2007 were prepared and irradiated at the Helmholtz Zentrum Munchen. Five out of six samples were irradiated at 0.1, 0.2, 0.5, 1.0 and 1.5 Gy air kerma; and one unirradiated s…

Detection limitMolarRadiationChemistryCalibration curvebusiness.industryTooth enamelKermamedicine.anatomical_structurestomatognathic systemCalibrationmedicineEpr dosimetryDosimetryNuclear medicinebusinessInstrumentationRadiation Measurements
researchProduct

Monte Carlo evaluation of kerma in an HDR brachytherapy bunker

2004

In recent years, the use of high dose rate (HDR) after-loader machines has greatly increased due to the shift from traditional Cs-137/Ir-192 low dose rate (LDR) to HDR brachytherapy. The method used to calculate the required concrete and, where appropriate, lead shielding in the door is based on analytical methods provided by documents published by the ICRP, the IAEA and the NCRP. The purpose of this study is to perform a more realistic kerma evaluation at the entrance maze door of an HDR bunker using the Monte Carlo code GEANT4. The Monte Carlo results were validated experimentally. The spectrum at the maze entrance door, obtained with Monte Carlo, has an average energy of about 110 keV, m…

Internationalitymedicine.medical_treatmentNuclear engineeringBrachytherapyPhysics::Medical PhysicsMonte Carlo methodBrachytherapyRadiation DosageRisk AssessmentKermaLead shieldingRadiation ProtectionRadiation MonitoringRisk FactorsOccupational ExposuremedicineScattering RadiationComputer SimulationHospital Design and ConstructionRadiology Nuclear Medicine and imagingMonte carlo evaluationLow dose rateSimulationPhysicsModels StatisticalRadiology Department HospitalRadiological and Ultrasound TechnologyMonte carlo codeDose rateMonte Carlo MethodPhysics in Medicine and Biology
researchProduct

Seasonal variation of air kerma rate in Sicily.

2007

Thermoluminescence dosimetry has been used to measure air kerma in 29 sites in Sicily. Four three month measurement campaigns have been carried out in order to assess seasonal variations. Average annual values between 20 and 90 nGy h(-1), after cosmic background subtraction, are reported. Average annual values are strongly dependent on site lithology, and we find that winter data are generally the highest, while spring and autumn rates are generally the lowest with very similar trends in any site. Summer values generally lay in between. Largest seasonal variations are found in sites along the southern coast of the island, probably because of stronger action of winds affecting radon, along w…

LithologyHealth Toxicology and MutagenesisAir pollutionchemistry.chemical_elementRadonmedicine.disease_causeAtmospheric sciencesKermaRadiation MonitoringmedicineEnvironmental ChemistryWaste Management and DisposalSicilyGeographybusiness.industryGeneral MedicineSeasonalitymedicine.diseasePollutionGround levelSpectrometry GammachemistryAir Pollutants RadioactiveThermoluminescence dosimetrySpatial variabilitySeasonsNuclear medicinebusinessJournal of environmental radioactivity
researchProduct

Gut microbiota disturbance during antibiotic therapy: a multi-omic approach

2014

It is known that the gastrointestinal tract (GIT) microbiota responds to different antibiotics in different ways and that while some antibiotics do not induce disturbances of the community, others drastically influence the richness, diversity, and prevalence of bacterial taxa. However, the metabolic consequences thereof, independent of the degree of the community shifts, are not clearly understood. In a recent article, we used an integrative OMICS approach to provide new insights into the metabolic shifts caused by antibiotic disturbance. The study presented here further suggests that specific bacterial lineage blooms occurring at defined stages of antibiotic intervention are mostly associa…

MaleAnabolismAntibioticsGene ExpressionGut floraGastrointestinal FunctionBioinformaticsprokaryotesFecesRNA Ribosomal 16SSystems and Synthetic Biologyhuman fecal microbiota1506MetaproteomicGut Microbiotadatabase2. Zero hungerlong-term impactsGastrointestinal tract0303 health sciencesSysteem en Synthetische Biologiehuman intestinal microbiotabiologyMicrobiotaGastroenterologyBiodiversity3. Good healthAnti-Bacterial AgentsBacterial Typing TechniquesArticle AddendumRNA BacterialInfectious DiseasesMetabolomecommunitymetaproteomicsHuman gut microbiotaMicrobiology (medical)DNA BacterialDisturbance (geology)medicine.drug_classperturbationMetabolomicbeta-LactamsMicrobiologyMicrobiologyresistance03 medical and health sciencesMetagenomicAntibiotic therapyMetabolomemedicineHumans030304 developmental biologyAgedVLAGBacteria030306 microbiologyGene Expression ProfilingColonic MicrofloraAkkermansiaAntibiotic therapybiology.organism_classificationGastrointestinal TractEnterococcusGene Expression RegulationMetaproteomicsMetatranscriptomicGastrointestinal functionmetabolismMeta-Analysis
researchProduct

Reducing Patient Radiation Dose With Image Noise Reduction Technology in Transcatheter Aortic Valve Procedures

2015

X-ray radiation exposure is of great concern for patients undergoing structural heart interventions. In addition, a larger group of medical staff is required and exposed to radiation compared with percutaneous coronary interventions. This study aimed at quantifying radiation dose reduction with implementation of specific image noise reduction technology (NRT) in transcatheter aortic valve implantation (TAVI) procedures. We retrospectively analyzed 104 consecutive patients with TAVI procedures, 52 patients before and 52 after optimization of x-ray radiation chain, and implementation of NRT. Patients with 1-step TAVI and complex coronary intervention, or complex TAVI procedures, were excluded…

Malemedicine.medical_specialtyPercutaneousImage quality030204 cardiovascular system & hematology030218 nuclear medicine & medical imagingTranscatheter Aortic Valve ReplacementIntraoperative Period03 medical and health sciencesKerma0302 clinical medicineGermanyInternal medicineMultidetector Computed TomographyImage noise reductionmedicineHumansFluoroscopyCardiac skeletonRadiation InjuriesRetrospective StudiesAged 80 and overmedicine.diagnostic_testbusiness.industryIncidenceDose-Response Relationship RadiationRetrospective cohort studyAortic Valve StenosisPrognosismedicine.diseaseSurgery Computer-AssistedFluoroscopyAortic valve stenosisCardiologyFemaleRadiologyCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesThe American Journal of Cardiology
researchProduct

Design and evaluation of a HDR skin applicator with flattening filter

2008

The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, made of tungsten, aim to flatten the heterogeneous dose distribution obtained with the Leipzig applicators. (ii) To estimate the dose rate distributions for these Leipzig+filter applicators by means of the Monte Carlo (MC) method. (iii) To experimentally verify these distributions for prototypes of these new applicators, and (iv) to obtain the correspondence factors to measure t…

Materials scienceDosimeterbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineImaging phantomKermaOpticsIonization chamberCalibrationmedicineDosimetrybusinessNuclear medicineMedical Physics
researchProduct

Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions

2016

Purpose: The aims of this study were (i) to design a new high-dose-rate (HDR) brachytherapy applicator for treating surface lesions with planning target volumes larger than 3 cm in diameter and up to 5 cm in size, using the microSelectron-HDR or Flexitron afterloader (Elekta Brachytherapy) with a 192Ir source; (ii) to calculate by means of the Monte Carlo(MC) method the dose distribution for the new applicator when it is placed against a water phantom; and (iii) to validate experimentally the dose distributions in water. Methods: The penelope2008MC code was used to optimize dwell positions and dwell times. Next, the dose distribution in a water phantom and the leakage dose distribution arou…

Materials sciencebusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineImaging phantomHigh-Dose Rate Brachytherapy030218 nuclear medicine & medical imagingPercentage depth dose curve03 medical and health sciencesKerma0302 clinical medicine030220 oncology & carcinogenesisIonization chambermedicineDosimetryNuclear medicinebusinessMedical Physics
researchProduct

Cross-regional view of functional and taxonomic microbiota composition in obesity and post-obesity treatment shows country specific microbial contrib…

2019

This work was supported by CONICYT-Chile through the FONDECYT [n° 3160525] (DM) and by Universidad San Sebastián, and by grants to AM from the Spanish Ministry of Economy and Competitiveness (projects SAF2012-31187, SAF2013-49788-EXP, SAF2015-65878-R), Carlos III Health Institute (Projects PIE14/00045 and AC15/00022), Generalitat Valenciana (Project PrometeoII/2014/065 and Prometeo/2018/A/133), Asociación Española Contra el Cancer (Project AECC 2017-1485) and co-financed by the European Regional Development Fund (ERDF).

Microbiology (medical)obesitybariatric surgerylcsh:QR1-502Context (language use)Gut floraMicrobiologydigestive systemlcsh:MicrobiologyFunctional redundancy03 medical and health sciencesMetagenomicWeight losshuman gut microbiotamedicineObesitymetagenomicOriginal Research030304 developmental biologyGeneticsBariatric surgery0303 health sciencesbiology030306 microbiologyMicrobiotaFunctional redundancyfunctional convergencebiology.organism_classificationmedicine.diseaseObesityfunctional redundancyMetagenomicsObesitatmedicine.symptomDysbiosisAkkermansia muciniphilaFunctional convergenceHuman gut microbiota
researchProduct

A Critical Perspective on the Supplementation of Akkermansia muciniphila: Benefits and Harms

2023

Akkermansia muciniphila is a mucin-degrading bacterium of the intestinal niche, exerting beneficial effects on the host metabolic profile. Accumulating evidence indicated Akkermansia as a promising therapeutic probiotic against metabolic disorders such as obesity, type 2 diabetes and cardiovascular diseases. However, in specific intestinal microenvironments, its excessive enrichment may be not beneficial. Conditions like inflammatory bowel disease (IBD), Salmonella typhimurium infection or post-antibiotic reconstitution may not benefit from Akkermansia supplementation. Furthermore, using Akkermansia in patients with endocrine and gynecological disorders—such as polycystic ovary syndrome (PC…

Microbiota.Space and Planetary ScienceIBDPCOSPaleontologyHarmBenefitEndometriosiSettore MED/40 - Ginecologia E OstetriciaGeneral Biochemistry Genetics and Molecular BiologyEcology Evolution Behavior and SystematicsAkkermansia muciniphila
researchProduct

Air-kerma evaluation at the maze entrance of HDR brachytherapy facilities.

2014

In the absence of procedures for evaluating the design of brachytherapy (BT) facilities for radiation protection purposes, the methodology used for external beam radiotherapy facilities is often adapted. The purpose of this study is to adapt the NCRP 151 methodology for estimating the air-kerma rate at the door in BT facilities. Such methodology was checked against Monte Carlo (MC) techniques using the code Geant4. Five different facility designs were studied for (192)Ir and (60)Co HDR applications to account for several different bunker layouts.For the estimation of the lead thickness needed at the door, the use of transmission data for the real spectra at the door instead of the ones emit…

Models Statisticalbusiness.industryComputer sciencemedicine.medical_treatmentMonte Carlo methodBrachytherapyBrachytherapyPublic Health Environmental and Occupational HealthGeneral MedicineRadiation DosageBunkerKermaRadiation ProtectionSpainmedicineScattering RadiationComputer SimulationHospital Design and ConstructionHealth FacilitiesRadiation protectionbusinessRadiometryWaste Management and DisposalMonte Carlo MethodSimulationJournal of radiological protection : official journal of the Society for Radiological Protection
researchProduct