Search results for "Kinetic analysis"
showing 10 items of 20 documents
Thermal analysis applied to the characterization of degradation in soil of polylactide: II. On the thermal stability and thermal decompositon kinetics
2010
[EN] The disposal stage of polylactide (PLA) was assessed by burying it in active soil following an international standard. Degradation in soil promotes physical and chemical changes in the polylactide properties. The characterization of the extent of degradation underwent by PLA was carried out by using Thermal Analysis techniques. In this paper, studies on the thermal stability and the thermal decomposition kinetics were performed in order to assess the degradation process of a commercial PLA submitted to an accelerated soil burial test by means of multi-linear-non-isothermal thermogravimetric analyses. Results have been correlated to changes in molecular weight, showing the same evolutio…
Reprocessed polylactide: Studies of thermo-oxidative decomposition
2012
The combustion process of virgin and reprocessed polylactide (PLA) was simulated by multi-rate linear non-isothermal thermogravimetric experiments under O2. A complete methodology that accounted on the thermal stability and emission of gases was thoroughly developed. A new model, Thermal Decomposition Behavior, and novel parameters, the Zero-Decomposition Temperatures, were used to test the thermal stability of the materials under any linear heating rate. The release of gases was monitored by Evolved Gas Analysis with in-line FT-IR analysis. In addition, a kinetic analysis methodology that accounted for variable activation parameters showed that the decomposition process could be driven by …
Thermal and thermo-oxidative stability of reprocessed poly(ethylene terephthalate)
2013
An exhaustive assessment of the behaviour of virgin and mechanically reprocessed poly(ethylene terephthalate) (PET) facing thermal and thermo-oxidative decomposition processes is presented in this work, as an approach for the energetic valorisation of post-consumer PET goods. Multi-rate linear-non-isothermal thermogravimetric (TGA) experiments under inert (Ar) and reactive (O2) conditions were performed to virgin PET and its recyclates in order to simulate the thermal behaviour of the materials facing pyrolysis and combustion processes. The release of gases was monitored by evolved gas analysis of the fumes of the TGA experiment, by in-line Fourier-transform infrared (IR) analysis, with the…
Kinetic Analysis of Aluminium Evaporation from the Ti-6Al-7Nb Alloy
2014
Abstract In the present paper, kinetics of aluminium evaporation from the Ti-6Al-7Nb alloy during smelting by means of the VIM method at 5 to 1000 Pa has been discussed. To determine the liquid titanium meniscus area and the liquid titanium mean velocity for the experimental conditions of the study, a methodology based on the coupled model of the electromagnetic field and the hydrodynamic field of liquid metal was applied.
A reaction engineering approach to kinetic analysis of photocatalytic reactions in slurry systems
2016
Abstract The knowledge of the rate equation is fundamental for the assessment of the activity of the photocatalytic material and for the study, design and optimization of photocatalytic reactors. In the case of photocatalytic reactions, the local volumetric rate of photon absorption (LVRPA) affects the reaction rate and its inherently uneven distribution within a “slurry” reactor makes complex a correct kinetic analysis. In the present work it is shown which are the critical aspects of the kinetic analysis in slurry reactors and how to carry out photocatalytic experiments to minimize the misinterpretations of the experimental results. In particular, the influence of the type of illumination…
A kinetic study of the formation of smectic phases in novel liquid crystal ionogens
2013
[EN] A multi-rate non-isothermal kinetic analysis of the isotropic-melt to liquid crystalline phase transition of novel liquid crystalline ionogenic copolymers, LCIs, the 10-(4-methoxyazobenzene-4'-oxy)decyl methacrylate]-co-2-(acrylamido-2-methyl-1-propanesulfonic acid)s, 10-MeOAzB/AMPS, copolymers, has been performed by means of calorimetric experiments. An analytical methodology which includes the study of the phase transition rate parameter, the determination of the activation energies by using Kissinger and Flynn-Wall-Ozawa models, and the study of the phase transition kinetics by the use of the Avrami theory, has been applied. The formation of the mesophases from the isotropic state o…
Experimental organic matter maturation at 2kbar: Heat-up effect to low temperatures on vitrinite reflectance
2012
Abstract An experimental study was performed to evaluate the effect of heat-up to various low temperatures on vitrinite reflectance ( VR ) at 2 kbar employing the same previously used heat-up procedures, starting material and apparatus. Heat-up is the isobaric experimental procedure consisting of the increase in temperature of the laboratory vitrinite maturation from room temperature to the desired run temperature T end of heat-up at which the isobaric-isothermal maturation starts. Experiments employed cold-seal pressure vessels with classical heat-up devices and were carried out on wet (water added) xylite of swamp cypress. Confined system maturation experiments were conducted at 2 kbar an…
Idarubicin-loaded beads for chemoembolisation of hepatocellular carcinoma: results of the IDASPHERE phase I trial
2014
SummaryBackground A phase I dose-escalation trial of transarterial chemoembolisation (TACE) with idarubicin-loaded beads was performed in cirrhotic patients with hepatocellular carcinoma (HCC). Aim To estimate the maximum-tolerated dose (MTD) and to assess safety, efficacy, pharmacokinetics and quality of life. Methods Patients received a single TACE session with injection of 2 mL drug-eluting beads (DEBs; DC Bead 300–500 μm) loaded with idarubicin. The idarubicin dose was escalated according to a modified continuous reassessment method. MTD was defined as the dose level closest to that causing dose-limiting toxicity (DLT) in 20% of patients. Results Twenty-one patients were enrolled, inclu…
Kinetic Analysis: A Sensitive Outcome Objective Measurement Method in Evaluating Lateral Patellar Instability
2011
There are many diagnostic clinical tests (e.g., apprehension patellar test or the moving patellar apprehension test), outcome measures (general health and knee scales [IKDC form, Kujala scale, Fulkerson scale, Lysholm knee scoring scale, Tegner activity level scale, short form-36]), and instrumented measurements of patellar mobility (static stability), to assess lateral patellar instability.7,10,15,16 However, according to Smith and colleagues,15 the sensitivity/specificity – reliability/validity of such tests and outcome tools remain unclear for this patient population. These authors conclude that further work is needed to assess the appropriateness of these tests and outcomes.15Moreover, …
The role of polaronic states in the enhancement of CO oxidation by single-atom Pt/CeO2
2023
Single Atom Catalysts (SACs) have shown that the miniaturization of the active site implies new phenomena like dynamic charge transfer between isolated metal atoms and the oxide. To obtain direct proof of this character is challenging, as many experimental techniques provide averaged properties or have limitations with poorly conductive materials, leaving kinetic measurements from catalytic testing as the only reliable reference. Here we present an integrated Density Functional Theory-Microkinetic model including ground and metastable states to address the reactivity of Pt1/CeO2 for CO oxidation. Our results agree with experimentally available kinetic data in the literature and show that CO…