Search results for "Knee joint"

showing 10 items of 177 documents

Contribution of the tendinous tissue to force enhancement during stretch–shortening cycle exercise depends on the prestretch and concentric phase int…

2005

When the prestretch intensity and concentric work are increased in stretch-shortening cycle (SSC) exercises, the utilization of the elastic energy can increase during the concentric phase. In order to further understand this process during SSC exercises, the interaction between fascicle-tendinous tissues (TT) of the vastus lateralis (VL) muscle was examined under different prestretch and rebound intensity drop jumps. Ten male subjects participated in the study. Direct VL fascicle lengths (N = 10) and in vivo patellar tendon force (N = 1) were measured together with the electromyographic (EMG) activity of VL during the trials. With increasing drop height but the same rebound height condition…

AdultMaleMaterials scienceKnee JointMovementPhysical ExertionBiophysicsNeuroscience (miscellaneous)Phase (waves)ConcentricTendonsHumansExercise physiologyMuscle SkeletalExerciseTension (physics)Work (physics)AnatomyFascicleAdaptation PhysiologicalIntensity (physics)body regionsStretch-Shortening Cycle ExerciseStress MechanicalNeurology (clinical)Muscle ContractionBiomedical engineeringJournal of Electromyography and Kinesiology
researchProduct

Neomuscular fatigue to power loading using a weight-stack device fitted with or without additional rubber band resistance

2014

The addition of a rubber band (RB) to traditional weight-based resistance may be beneficial regarding the deceleration phase common during explosive power actions with light weights. This would lead to greater force and muscle activity during the latter part of the movement, but this may influence the distribution of neuromuscular fatigue. Fifteen men performed 2 knee extension power loadings (5 × 5 × 40% of 1 repetition maximum [1RM]) using a typical weight-stack device without (WS) and with the addition of a RB (WS + RB) in a crossover design. Concentric contractions were performed as fast as possible, and analyzed for torque, velocity, power, and vastus lateralis and medialis surface ele…

AdultMaleMaterials scienceKnee JointPhysical Therapy Sports Therapy and RehabilitationIsometric exerciseElectromyographyConcentricQuadriceps MuscleRoot mean squareYoung AdultIsometric ContractionmedicineHumansOrthopedics and Sports MedicineLactic AcidMuscle StrengthLead (electronics)ta315Cross-Over StudiesMuscle fatiguemedicine.diagnostic_testElectromyographyResistance TrainingGeneral MedicineAmplitudeTorqueMuscle FatigueExercise TestRange of motionBiomedical engineeringThe Journal of Strength and Conditioning Research
researchProduct

Measurement of EMG activity with textile electrodes embedded into clothing.

2007

Novel textile electrodes that can be embedded into sports clothing to measure averaged rectified electromyography (EMG) have been developed for easy use in field tests and in clinical settings. The purpose of this study was to evaluate the validity, reliability and feasibility of this new product to measure averaged rectified EMG. The validity was tested by comparing the signals from bipolar textile electrodes (42 cm(2)) and traditional bipolar surface electrodes (1.32 cm(2)) during bilateral isometric knee extension exercise with two electrode locations (A: both electrodes located in the same place, B: traditional electrodes placed on the individual muscles according to SENIAM, n=10 person…

AdultMaleMaterials scienceKnee JointPhysiologyAverage rectified valueCoefficient of variationTransducersBiomedical EngineeringBiophysicsMonitoring AmbulatoryIsometric exerciseElectromyographySports MedicineSignalSensitivity and SpecificityClothingPhysiology (medical)Isometric ContractionmedicineHumansTreadmillElectrodesExerciseSimulationAnalysis of Variancemedicine.diagnostic_testElectromyographyTextilesReproducibility of ResultsRepeatabilityEquipment DesignMiddle AgedEquipment Failure AnalysisTorqueElectrodeFemaleBiomedical engineeringPhysiological measurement
researchProduct

Kinetic and electromyographic analysis of single repetition constant and variable resistance leg press actions

2010

During a multi-joint leg press action, maximal force capabilities increase with increasing knee angle. In typical resistance exercises, constant resistance is used, which does not stress the neuromuscular system at large knee angles. The purpose of this study was to compare constant and variable resistance settings using a range of contraction loads and velocities. Nine healthy, untrained males performed single contractions using four different resistance settings (constant resistance, two settings that increased resistance at large knee angles and one setting that reduced resistance at large knee angles). Single contractions using 40%, 60%, and 80% of one repetition maximum with both stead…

AdultMaleMaterials scienceKnee JointVastus medialisPhysical ExertionBiophysicsNeuroscience (miscellaneous)ElectromyographyConcentricBicepsOne-repetition maximummedicineHumansMuscle Skeletalta315Leg pressmedicine.diagnostic_testElectromyographyResistance TrainingAnatomyAdaptation PhysiologicalKineticsLarge kneeNeurology (clinical)Range of motionMuscle ContractionBiomedical engineeringJournal of Electromyography and Kinesiology
researchProduct

Medial gastrocnemius muscle behavior during human running and walking.

2007

Utilization of elastic energy in the tendinous tissues (TT) of the human skeletal muscle may be task dependent. The present study was designed to investigate this problem by comparing the fascicle-TT interaction of the medial gastrocnemius muscle (MG) during ground contact of running and walking. Seven subjects ran and walked with a natural cadence. Ankle and knee joint angular data were recorded by electrogoniometers for estimating the entire MG muscle-tendon unit (MTU) length, together with the ground reaction forces. The MG fascicle length was measured by using the high-speed ultrasound image scanning during movements. The results showed that in running, after the rapid early fascicle st…

AdultMaleMaterials scienceMuscle RelaxationMuscle Fibers SkeletalBiophysicsMedial gastrocnemiusWalkingKnee JointSarcomereRunningmedicineHumansOrthopedics and Sports MedicineGround reaction forceMuscle SkeletalUltrasonographyLegElectromyographyRehabilitationSkeletal muscleAnatomyFasciclemedicine.anatomical_structureAnkleCadenceMuscle ContractionGaitposture
researchProduct

Helicobacter sp. strain Mainz isolated from an AIDS patient with septic arthritis: case report and nonradioactive analysis of 16S rRNA sequence

1994

A campylobacter-like organism was isolated from an effusion of the left knee joint of an AIDS patient 2 weeks after bacteremia with a morphologically identical organism. Amplified genomic 16S rRNA sequences were analyzed by a nonradioactive blotting technique. The closest match was found with Helicobacter fenelliae (97.7% homology). Sequence data and phenotype suggest that the isolate may represent a so far unrecognized species of the genus Helicobacter.

AdultMaleMicrobiology (medical)Knee JointMolecular Sequence DataBiologyHelicobacter InfectionsHelicobacterRNA Ribosomal 16SGenotypemedicineHumansTypingHelicobacterRibosomal DNAAcquired Immunodeficiency SyndromeArthritis InfectiousBase SequenceSequence Analysis RNAbiology.organism_classificationmedicine.disease16S ribosomal RNAVirologyPhenotypeBacteremiaSeptic arthritisResearch ArticleJournal of Clinical Microbiology
researchProduct

Cellular ultrastructure of the ruptured anterior cruciate ligament. A transmission electron microscopic and immunohistochemical study in 55 cases.

1994

To evaluate the cellular ultrastructure following injury, we examined the anterior cruciate ligaments in 55 patients with complete tears in different phases after the injury and compared them to a control group of 39 cadaver knees. Samples were analyzed by electron microscopy, immunofluorescence, and ultramorphometry. After an invasion of inflammatory cells into the stumps of the ruptured ligaments, a marked proliferation of fibroblasts was found at the end of Phase 1 (2-3 days after the ligament injury), that was even more pronounced at the beginning of Phase II (4-17 days). These cells were initially highly metabolically active and secreted Type III collagen precursors. In Phase III (4-45…

AdultMalePathologymedicine.medical_specialtyAdolescentKnee JointAnterior cruciate ligamentBiopsyFluorescent Antibody TechniqueImmunofluorescenceBiopsymedicineCadaverHumansOrthopedics and Sports MedicineAnterior Cruciate LigamentFibroblastRuptureWound Healingmedicine.diagnostic_testbusiness.industryAnterior Cruciate Ligament InjuriesAnatomyFibroblastsMiddle AgedMicroscopy Electronmedicine.anatomical_structureUltrastructureTearsImmunohistochemistrySurgeryFemaleWound healingbusinessCell DivisionActa orthopaedica Scandinavica
researchProduct

Stretch shortening cycle fatigue: interactions among joint stiness, reflex, and muscle mechanical performance in the drop jump

1996

The purpose of the present study was to investigate the effect of strenuous stretch-shortening cycle exercise on the relationship between reflex and stiffness regulation during the drop jump. Ten healthy male subjects performed submaximal stretch-shortening cycle exercise on a special sledge apparatus. Exhaustion occurred on average within 3 min. A drop jump test from a 50-cm height was performed immediately before and after the sledge exercise, as well as 2 h, 2 days and 4 days later. The fatigue exercise showed relatively high blood lactate concentrations 12.5 (SD 2.6) mmol·l−1 and a 2-day delayed increase of serum cretaine kinase concentration. In drop jumps, the short latency M1 compone…

AdultMaleReflex Stretchmedicine.medical_specialtyKnee JointPhysiologyVastus lateralis musclePhysical exerciseElectromyographymedicine.disease_causeStretch shortening cycleJumpingPhysiology (medical)Internal medicineHumansMedicineOrthopedics and Sports MedicineLactic AcidStretch reflexExercise physiologyMuscle SkeletalCreatine KinaseExercisemedicine.diagnostic_testElectromyographybusiness.industryPublic Health Environmental and Occupational HealthGeneral Medicinemedicine.anatomical_structureMuscle FatigueCardiologyReflexPhysical therapyJointsbusinessEuropean Journal of Applied Physiology and Occupational Physiology
researchProduct

Cycling exercise and the determination of electromechanical delay.

2007

The main aim of the present paper was to address the validity of a methodology proposed in a previous paper [Li L, Baum BS. Electromechanical delay estimated by using electromyography during cycling at different pedaling frequencies. J Electromyogr Kinesiol 2004;14(6):647-52], aimed at determining the electromechanical delay from pedaling exercise performed at various cadences. Twelve trained subjects undertook pedaling bouts corresponding to combinations of cadences ranging from 50 to 100 RPM and power output from 37.5% to 75% of Pmax. As cadence increased, peak torque angle was found to shift forward in crank cycle (from 60-65 degrees at 50 RPM to 75-80 degrees at 100 RPM, depending on th…

AdultMaleTime FactorsKnee JointPhysical ExertionBiophysicsNeuroscience (miscellaneous)ElectromyographyControl theoryTask Performance and AnalysismedicineTorqueMuscular forceHumansPower outputMuscle SkeletalMathematicsCrankmedicine.diagnostic_testCoactivationBicyclingTorqueExercise TestHip JointNeurology (clinical)CadenceCyclingMuscle ContractionJournal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
researchProduct

EMG power spectrum and features of the superimposed M-wave during voluntary eccentric and concentric actions at different activation levels.

2001

Muscle fiber conduction velocity (CV) may be affected by the level of voluntary activation and by the diameter of the fiber. Both the frequency component of the electromyography (EMG) power spectrum, such the as median frequency (MF) or mean power frequency, and the duration of muscle compound action potential to single supramaximal electrical impulse (maximal M-wave) may be related to CV. The aim of the present study was to examine how changes in the activation level in lengthening and in shortening conditions would affect the EMG power spectrum during voluntary effort, and compare them to changes in M-wave shape in similar conditions. Ten male subjects performed eccentric and concentric k…

AdultMaleVolitionAdolescentKnee JointVastus medialisMuscle Fibers SkeletalElectromyographyConcentricNerve conduction velocityPhysiology (medical)medicineEccentricHumansOrthopedics and Sports MedicineMuscle Skeletalmedicine.diagnostic_testChemistryElectromyographyPublic Health Environmental and Occupational HealthElectric ConductivityGeneral MedicineAnatomyEvoked Potentials MotorCompound muscle action potentialElectrophysiologymedicine.symptomMuscle contractionBiomedical engineeringMuscle ContractionEuropean journal of applied physiology
researchProduct