Genomic investigation of a legionellosis outbreak in a persistently colonized hotel
2016
Objectives: A long-lasting legionellosis outbreak was reported between November 2011 and July 2012 in a hotel in Calpe (Spain) affecting 44 patients including six deaths. Intensive epidemiological and microbiological investigations were performed in order to detect the reservoirs. Methods: Clinical and environmental samples were tested for the presence and genetic characterization of Legionella pneumophila. Six of the isolates were subjected to whole-genome sequencing. Results: Sequencing of 14 clinical and 260 environmental samples revealed sequence type (ST) 23 as the main responsible strain for the infections. This ST was found in the spa pool, from where it spread to other hotel public …
Control and prevention measures for legionellosis in hospitals: A cross-sectional survey in Italy
2018
Abstract Risk assessment, environmental monitoring, and the disinfection of water systems are the key elements in preventing legionellosis risk. The Italian Study Group of Hospital Hygiene of the Italian Society of Hygiene, Preventive Medicine, and Public Health and the Italian Multidisciplinary Society for the Prevention of Health Care-Associated Infections carried out a national cross-sectional survey to investigate the measures taken to prevent and control legionellosis in Italian hospitals. A multiple-choice questionnaire was developed, comprising 71 questions regarding hospital location, general characteristics, clinical and environmental surveillance, and control and preventive measur…
Clinical Epidemiological Survey of Legionella pneumophila Infections in Italy
1986
A clinical epidemiological survey of Legionella pneumophila infections occurring in Italy between 1 December 1985 and 31 May 1986 was carried out to evaluate the incidence of sporadic, epidemic and nosocomial L. pneumophila pneumonia. A total of 355 cases of pneumonia were studied of which 11.5% were due to Gram positive bacteria, 11% were due to Gram negative bacteria, 7.9% were due to Mycoplasma pneumoniae, 4.5% were due to L. pneumophila and 8.5% were due to sundry aetiological agents. The remainder (45.6%) could not be diagnosed accurately. In addition, the anti L. pneumophila antibody titres were assessed. The results are discussed in terms of the occurrence of the disease in Italy an…
Can technical, functional and structural characteristics of dental units predict Legionella pneumophila and Pseudomonas aeruginosa contamination?
2011
Legionella pneumophila and Pseudomonas aeruginosa are common colonizers of water environments, particularly dental unit waterlines. The aim of this study was to assess whether the technical, functional and structural characteristics of dental units can influence the presence and the levels of opportunistic pathogens. Overall, 42 water samples were collected from dental units in a teaching hospital in Palermo, Italy, including 21 samples from the 21 taps supplied by the municipal water distribution system and 21 samples from oral rinsing cups at 21 dental units. L. pneumophila was present in 16 out of 21 water samples (76.2%) from dental units, and the median concentration was higher in samp…
[Legionella spp. contamination in indoor air: preliminary results of an Italian multicenter study].
2014
Obiettivo. Rilevare la presenza di Legionella spp. nell’aria attraverso un protocollo standardizzato, a fianco dei tradizionali metodi impiegati per la rete idrica. Disegno. In dieci strutture sanitarie è stato selezionato un bagno, la cui acqua presentava una contaminazione da Legionella >1.000 unità formanti colonie (ufc)/litro. La contaminazione dell’aria è stata valutata tramite campionamento attivo (Surface Air System, SAS) e passivo, impiegando piastre di sedimentazione per la valutazione dell’Indice Microbico Aria (Index of Microbial Air, IMA). I campionamenti sono stati effettuati per 8 ore consecutive, a circa 1 m dal pavimento e a 50 cm dal rubinetto. Con il campionamento attivo, …
Erfassung niedriger Legionellen-Konzentrationen in Badebeckenwasser
2001
The Legionella proof is necessary in pool water according to DIN 19 643 in case of possible aerosol formation. In lab tests it was proven that the direct spatulation of 1 ml water offers high-grade proof with high correlation of the determined concentration to the actual germ content. With very small germ concentrations, however, preceding filtration of larger sample volumes is necessary. During the investigation of routine samples a Legionella proof was possible thereby in individual cases, whereas direct spatulation remained negative.
Geographical and temporal structures of Legionella pneumophila sequence types in comunitat valenciana (Spain), 1998 to 2013
2015
ABSTRACT Legionella pneumophila is an accidental human pathogen associated with aerosol formation in water-related sources. High recombination rates make Legionella populations genetically diverse, and nearly 2,000 different sequence types (STs) have been described to date for this environmental pathogen. The spatial distribution of STs is extremely heterogeneous, with some variants being present worldwide and others being detected at only a local scale. Similarly, some STs have been associated with disease outbreaks, such as ST578 or ST23. Spain is among the European countries with the highest incidences of reported legionellosis cases, and specifically, Comunitat Valenciana (CV) is the se…
Impact of biocide treatments on the bacterial communities of the Lascaux Cave.
2009
The Lascaux Cave contains a remarkable set of paintings from the Upper Palaeolithic. Shortly after discovery in 1940, the cave was modified for public viewing and, in 2001, was invaded by a Fusarium solani species complex. Benzalkonium chloride was used from 2001 to 2004 to eliminate the fungal outbreak. In this study, we carried out a sampling in most of the cave halls and galleries. Sequence analysis and isolation methods detected that the most abundant genera of bacteria were Ralstonia and Pseudomonas. We suggest that, as a result of years of benzalkonium chloride treatments, the indigenous microbial community has been replaced by microbial populations selected by biocide application.
Genotyping of Legionella pneumophila serogroup 1 strains isolated in Northern Sicily, Italy.
2008
During a three-year period, from April 2002 to May 2005, one hundred-forty-seven samples, taken from technical systems of water distribution at point of use, were repeatedly collected at six different sites in Northern Sicily and assayed for the presence of Legionella pneumophila serogroup 1 and serogroups 2 to 14. At the first samplings, the water distribution systems of all the sites were heavily contaminated, and disinfection treatments by the superheat and flush method were therefore performed. Treatments were always successful against L. pneumophila sg.1, but only in a few cases against all other serogroups. Eighty-six strains of L. pneumophila sg. 1, isolated from 26 of these samples,…
Oligonucleotide-capped mesoporous silica nanoparticles as DNA-responsive dye delivery systems for genomic DNA detection
2015
[EN] New hybrid oligonucleotide-capped mesoporous silica nanoparticles able to detect genomic DNA were designed.