Search results for "LENS"

showing 10 items of 948 documents

Depth of focus through different intraocular lenses in patients with different corneal profiles using adaptive optics visual simulation

2011

PURPOSE: To evaluate the depth of focus with monofocal intraocular lenses (IOLs) in patients with different corneal profiles using adaptive optics (AO) visual simulation. METHODS: An AO visual simulator (crx1, Imagine Eyes) was used to simulate the aberration pattern of three monofocal IOLs (Acrysof IQ SN60WF [Alcon Laboratories Inc]; Akreos Adapt AO [Bausch & Lomb]; and Triplato [AJL Ophthalmic]) of different optic designs. Five groups were considered: patients without any corneal refractive surgery (normal cornea group) and with prior low and high myopic and hyperopic ablations (low myopic ablation, high myopic ablation, low hyperopic ablation, and high hyperopic ablation groups). De…

AdultDepth of focusVisual acuityCorneal Wavefront AberrationPseudophakiagenetic structuresmedicine.medical_treatmentVisual AcuityCorneaYoung AdultLens Implantation IntraocularCorneaRefractive surgerymedicineHumansDioptreLenses IntraocularDepth Perceptionbusiness.industryAblationRefractive Errorseye diseasesOphthalmologySpherical aberrationmedicine.anatomical_structureOptometryOftalmologíaSurgerysense organsmedicine.symptomDepth perceptionbusiness
researchProduct

Influence of the luminance level on visual performance with a disposable soft cosmetic tinted contact lens.

2001

The purpose of the present work was to study the effect on visual performance of wearing disposable soft tinted contact lenses for cosmetic purposes. Parameters such as contrast sensitivity (Vistech 6000), colour vision (Farnsworth-Munsell 100-Hue colour test), visual fields (static Goldmann perimetry) and subjective vision (what the wearer feels while wearing the lenses) were studied under different illumination levels in order to check for possible vision losses while wearing these contact lenses at low illumination levels. Sixteen emmetropic subjects were fitted consecutively with seven pairs of different colour lenses (Optima Colors lenses by BauschLomb), and the experimental parameters…

AdultGoldmann perimetryAdolescentmedia_common.quotation_subjectColour VisionEmmetropiaColorContact Lenses HydrophilicLuminanceSensory SystemsContact lensContrast SensitivityOphthalmologyContrast (vision)OptometryHumansVisual Field TestsVisual FieldsColor PerceptionLightingVision OcularOptometryMathematicsmedia_commonOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Conditional reasoning by mental models: chronometric and developmental evidence

2000

The aim of this article is to verify two predictions resulting from the mental models theory of conditional reasoning. First, the denial of antecedent (DA) and modus tollens (MT) inferences should take longer to verify than modus ponens (MP) and affirmation of consequent (AC) because the former require subjects to flesh out the initial model whereas the latter do not. This prediction was confirmed in two reaction time experiments in adults. In line with Evans' proposal (Evans, J. St. B. T. (1993). The mental model theory of conditional reasoning: critical appraisal and revision. Cognition, 48, 1-20), there was a strong directionality effect: inferences from antecedent to consequent (MP and …

AdultLinguistics and LanguageAdolescentAntecedent (logic)Cognitive NeuroscienceInferenceExperimental and Cognitive PsychologyCognitionConditional reasoningLanguage and LinguisticsModus tollensCognitionReaction TimeDevelopmental and Educational PsychologyCognitive developmentHumansChildPsychological TheoryConstruct (philosophy)PsychologyModus ponensSocial psychologyCognitive psychologyCognition
researchProduct

Changes in Accommodation and Ocular Aberration With Simultaneous Vision Multifocal Contact Lenses

2012

Objective: The aim of this study was to evaluate ocular aberration changes through different simultaneous vision multifocal contact lenses (CLs). Methods: Eighteen young-adult subjects with a mean age of 29.8 +/- 2.11 years took part. Changes in accommodative response, spherical aberration (C-4(0)), horizontal coma (C-3(1)), vertical coma (C-3(-1)), and root mean square (RMS) of higher-order aberrations (HOAs, third to sixth orders) were evaluated. Measurements were obtained with a distance-single vision CL and 2 aspheric multifocal CLs of simultaneous focus center-near design (PureVision Low Add and PureVision High Add) for 2 accommodative stimuli (-2.50 and -4.00 D). All measurements were…

AdultMaleAccommodative responseCross-Over StudiesOptical Phenomenagenetic structuresContact Lensesbusiness.industryVisual AcuityAccommodation OcularComa (optics)Mean ageRefraction Oculareye diseasesOphthalmologyOcular physiologySpherical aberrationCLs upper limitsHumansMedicineOptometryFemalebusinessAccommodationEye & Contact Lens: Science & Clinical Practice
researchProduct

Accommodative Functions with Multifocal Contact Lenses: A Pilot Study

2011

PURPOSE: To evaluate accommodative response and facility in presbyopic patients fitted with several types of simultaneous-image multifocal contact lenses (CLs). METHODS: Six presbyopic patients, unadapted wearers of simultaneous-image bifocals, were fitted with the Focus Progressives and the low- and high-addition Pure Vision simultaneous vision multifocal CLs. Each individual wore each of the three types of lenses in successive random order. Accommodative response, accommodative facility, visual acuity, and contrast sensitivity at distance and near were evaluated in all cases. A control group of eight non-presbyopic patients was also studied. RESULTS: The mean age was 28.6 +/- 2.72 and 51.…

AdultMaleAccommodative responseDistance visual acuityVisual acuityContact Lensesmedia_common.quotation_subjectVisual AcuityPilot ProjectsContrast SensitivityNear visionHumansMedicineContrast (vision)media_commonbusiness.industryAccommodation OcularEquipment DesignPresbyopiaPresbyopiaMiddle AgedPrognosismedicine.diseaseOphthalmologyOptometryFemalemedicine.symptombusinessAccommodationMaximum amplitudeFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

Contrast sensitivity and glare disability by halogen light after monofocal and multifocal lens implantation

2000

BACKGROUND—Standard examination of contrast sensitivity under conditions of glare disability is performed with incandescent light. A new halogen glare test that simulates glare as seen with oncoming vehicle headlights was used to measure glare disability in patients implanted with multifocal and monofocal intraocular lenses (IOLs). METHODS—28 patients with an average age of 69 years (SD 12 years) were implanted with a monofocal IOL (SI-40NB, Allergan) and 28 patients with an average of 66 years (12 years) were implanted with a refractive multifocal IOL (Array-SA-40N, Allergan). All patients were followed for 5 months postoperatively. Contrast sensitivity at four spatial frequencies (3, 6, 1…

AdultMaleAgingAutomobile Drivingmedicine.medical_specialtygenetic structuresEye diseasemedicine.medical_treatmentmedia_common.quotation_subjecteducationPoison controlIntraocular lensAstigmatismGlareContrast SensitivityVision disorderCellular and Molecular NeuroscienceHalogensOphthalmologymedicineHumansContrast (vision)Postoperative PeriodDioptreAgedmedia_commonAged 80 and overLenses Intraocularbusiness.industryGlare (vision)Middle AgedOriginal articles - Clinical sciencemedicine.diseaseeye diseasesSensory SystemsSurgeryOphthalmologyFemalesense organsmedicine.symptombusinessFollow-Up StudiesBritish Journal of Ophthalmology
researchProduct

A simple description of age-related changes in crystalline lens thickness.

2010

Purpose An increase in lens thickness is often described as a linear function of age. However, contradictory opinions exist about whether the lens thickness continues to increase after 50 years of age. Differences in slope exist between this increase in younger and older people, but these findings are inconsistent with the linear behavior of an increase in the lens thickness throughout life. We investigated among different functions, including slope variation, which would be the best to show the relation between lens thickness and age. An available model portraying lens growth could be advantageous in many practical applications. The possibility of differences between sexes in lens thicknes…

AdultMaleAgingBiometryAdolescentLens (geology)03 medical and health sciencesYoung Adult0302 clinical medicineStatistical variabilityLens thicknessAge relatedStatisticsLens CrystallineRange (statistics)HumansMathematicsAgedAged 80 and overLinear function (calculus)General MedicineMiddle AgedOphthalmology030221 ophthalmology & optometryFemaleOlder people030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

Spectral Transmission of the Human Crystalline Lens in Adult and Elderly Persons: Color and Total Transmission of Visible Light

2012

Purpose To experimentally measure the spectral transmission of human crystalline lenses belonging to adult and elderly persons, and to determine the color and total transmission of visible light of such crystalline lenses. Methods The spectral transmission curve of 32 human crystalline lenses was measured using a PerkinElmer 800UV/VIS spectrometer. Total transmission of visible light and the chromatic coordinates of these crystalline lenses were determined from these curves for solar illumination. Results The crystalline lens that filters UV and its transmission in the visible spectrum decreases with age; such a decrease is greater for short wavelengths. The total transmission of visible li…

AdultMaleAgingMaterials scienceUltraviolet RaysColorMineralogylaw.inventionOpticsElderly personslawLens CrystallineTransmittanceHumansChromatic scaleAgedSunlightSpectrometerbusiness.industrySpectrum AnalysisMiddle Agedeye diseasesLens (optics)WavelengthSunlightFemalesense organsbusinessPhotic StimulationVisible spectrumInvestigative Opthalmology & Visual Science
researchProduct

Repeatability assessment of biometric measurements with different refractive states and age using a swept-source biometer

2018

Background We aim to assess if refractive error or age may influence the repeatability of measurements using a swept-source biometer. Methods A total of 61 subjects were evaluated with IOLMaster 700 acquiring measurements of axial length (AL), central corneal thickness (CCT), white-to-white distance (WTW), anterior aqueous depth (AQD), lens thickness (LT), and keratometry (K) readings. Repeatability was evaluated classifying the sample according to the refractive state and age by the calculation of the within-subject standard deviation (Sw), coefficient of repeatability, and intraclass correlation coefficient. Results Very similar Sw was acquired among groups for AL, CCT, and WTW. Differenc…

AdultMaleAgingRefractive errormedicine.medical_specialtyBiometryIntraclass correlationBiomedical Engineering030204 cardiovascular system & hematologyAstigmatismStandard deviationlaw.inventionYoung Adult03 medical and health sciences0302 clinical medicineLens thicknessAge groupslawOphthalmologyLens CrystallinemedicineHumansMathematicsKeratometerAge FactorsReproducibility of ResultsGeneral MedicineRepeatabilityMiddle AgedRefractive Errorsmedicine.diseaseAxial Length EyeFemaleSurgeryTomography Optical Coherence030217 neurology & neurosurgeryExpert Review of Medical Devices
researchProduct

Distribution of Anterior Chamber Angle Width and Correlation With Age, Refraction, and Anterior Chamber Depth—The Gutenberg Health Study

2016

PURPOSE Scheimpflug imaging allows quantitative analysis of the width of the anterior chamber angle. We report the population-based distribution of the anterior chamber angle width using this noncontact imaging technique and investigate associated factors. METHODS A population-based cross-sectional study was carried out in Germany. A comprehensive ophthalmologic examination including refraction, biometry, and Scheimpflug imaging was performed. Automated measurement of the anterior chamber angle was performed in each anterior chamber quadrant. Exclusion criteria were previous ocular surgery or inadequate image quality. Association analyses were carried out to determine independently associat…

AdultMaleAnterior ChamberOcular surgeryScheimpflug principlePopulationGlaucoma610 Medicine & healthDiagnostic Techniques OphthalmologicalRefraction OcularAnterior chamber angleCornea03 medical and health sciences0302 clinical medicineRisk FactorsGermanyLens CrystallinemedicineHumans610 Medicine & healtheducationAgedSex Characteristicseducation.field_of_studybusiness.industryAge FactorsAstigmatismMiddle Agedmedicine.diseaseRefractionCross-Sectional StudiesOphthalmologic examination030221 ophthalmology & optometryFemaleGlaucoma Angle-ClosureNuclear medicinebusiness030217 neurology & neurosurgeryShallow anterior chamberInvestigative Opthalmology & Visual Science
researchProduct