Search results for "LIABILITY"

showing 10 items of 1754 documents

Interexaminer reliability of low back pain assessment using the McKenzie method.

2002

STUDY DESIGN A test-retest design was used. OBJECTIVE To assess interexaminer reliability of the McKenzie method for performing clinical tests and classifying patients with low back pain. SUMMARY OF BACKGROUND DATA Clinical methods and tests classifying patients with nonspecific low back pain have been based mainly on symptom duration or extent of pain referral. The McKenzie mechanical diagnostic and classification approach is a widely used noninvasive, low-technology method of assessing patients with low back pain. However, little is known about the interexaminer reliability of the method, previous studies having yielded conflicting results. METHODS For this study, 39 volunteers with low b…

AdultMalemedicine.medical_specialtyConcordanceCohen's kappaPredictive Value of TestsMedicineHumansOrthopedics and Sports MedicineReliability (statistics)FinlandPain MeasurementContingency tableObserver Variationbusiness.industryReproducibility of ResultsMiddle AgedLow back painPredictive value of testsPhysical therapyMcKenzie methodFemaleNeurology (clinical)medicine.symptombusinessLow Back PainKappaSpine
researchProduct

Reliability of the Dynamic Gait Index (Finnish version) in individuals with neurological disorders

2012

To produce a Finnish version of the Dynamic Gait Index (DGI) and establish its reliability in people with neurological disorders affecting balance.A consecutive sample of 33 participants in inter-rater and 30 participants in intra-rater sample were tested. The DGI was administered in two testing sessions 1-2 h apart. Reliability was assessed with the intra-class correlation coefficient (ICC), Bland-Altman 95% limits of agreement, coefficient of reproducibility (CR), and standard error of the mean (SEM).The instructions from the original DGI were preserved during the translation process with no need for cultural adaptations. The relative reliability of the total scores proved to be high in i…

AdultMalemedicine.medical_specialtyCorrelation coefficientStatistics NonparametricCONSECUTIVE SAMPLEDisability EvaluationPhysical medicine and rehabilitationmedicineHumansPostural BalanceFinlandGait Disorders NeurologicReliability (statistics)AgedBalance (ability)Aged 80 and overObserver VariationReproducibilityDynamic gait indexRehabilitationReproducibility of Resultsta3141Middle AgedGaitStandard errorPhysical therapyFemalePsychologyDisability and Rehabilitation
researchProduct

Development and validation of the EUROLIGHT questionnaire to evaluate the burden of primary headache disorders in Europe

2010

We developed a 103-item self-reporting questionnaire to assess the burden of primary headache disorders on those affected by them, including headache characteristics, associated disability, co-morbidities, disease-management and quality of life. We validated the questionnaire in five languages with 426 participants (131 in UK, 60 in Italy, 107 in Spain, 83 in Germany/Austria, and 45 in France). After a linguistic and a face-content validation, we tested the questionnaire for comprehensibility, internal consistency and test–retest reliability at an interval of one month. In the different countries, response rates were between 73% and 100%. Test–retest reliability varied between –0.27 to 1.0…

AdultMalemedicine.medical_specialtyHeadache DisordersMedizinMEDLINEComorbidityGermanCost of IllnessQuality of lifeSurveys and QuestionnairesInternal consistencyHumansMedicinePsychiatryReliability (statistics)Languagebusiness.industryReproducibility of ResultsGeneral MedicineMiddle Agedmedicine.diseaseComorbiditylanguage.human_languageEuropelanguageFemaleNeurology (clinical)Headachesmedicine.symptombusinessPrimary Headache DisordersCephalalgia
researchProduct

Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests

2017

The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plo…

AdultMalemedicine.medical_specialtyHeteroscedasticityIntraclass correlationPosturePopulationBiophysicsTraumatologyCorrelation03 medical and health sciencessymbols.namesake0302 clinical medicineActivities of Daily LivingmedicineHumansOrthopedics and Sports MedicineArthroplasty Replacement KneeeducationGaitReliability (statistics)AgedAged 80 and overObserver Variationeducation.field_of_studybusiness.industryRehabilitationReproducibility of ResultsRecovery of Function030229 sport sciencesMiddle AgedConfidence intervalPearson product-moment correlation coefficientsymbolsPhysical therapyFemalebusiness030217 neurology & neurosurgeryGait & Posture
researchProduct

Towards an international language for incontinence-associated dermatitis (IAD): design and evaluation of psychometric properties of the Ghent Global …

2018

Background Incontinence-associated dermatitis (IAD) is a specific type of irritant contact dermatitis with different levels of severity. An internationally accepted instrument to assess the severity of IAD in adults with established diagnostic accuracy, agreement, and reliability is needed to support clinical practice and research.Objectives To design and psychometrically evaluate the Ghent Global IAD Categorisation Tool (GLOBIAD).Methods The design was based on expert consultation using a three-round Delphi procedure with 34 experts from 13 countries. The instrument was tested using IAD photographs reflecting different severity levels in a sample of 823 health professionals in 30 countries…

AdultMalemedicine.medical_specialtyInternationalityPsychometricsPsychometricsFleiss' kappaDermatologySensitivity and SpecificitySeverity of Illness Index030207 dermatology & venereal diseases03 medical and health sciences0302 clinical medicineTerminology as TopicSeverity of illnessMedicineHumans030212 general & internal medicineLanguageObserver Variationbusiness.industryIntra-rater reliabilityReference StandardsConfidence interval3. Good healthInter-rater reliabilityUrinary IncontinenceCategorization030220 oncology & carcinogenesisPhysical therapyDermatitis IrritantFemalebusinessKappa
researchProduct

Performance of a new device for the clinical determination of light discomfort

2020

PURPOSE To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was assessed by means of within-subject standard deviation, coefficient of variation (CoV), and intraclass correlation coefficient (ICC). Repeated measures ANOVA, Kruskal-Wallis, and correlation analysis were applied to test for differences between repeated measures, and effect of age on reliability. RESULTS Discomfort thresholds obtained are well distributed across the light intensity…

AdultMalemedicine.medical_specialtyLightIntraclass correlationCoefficient of variationBiomedical Engineering030204 cardiovascular system & hematologyAudiologyStandard deviationYoung Adult03 medical and health sciences0302 clinical medicineHumansMedicineReliability (statistics)AgedReproducibilitybusiness.industryReproducibility of ResultsRepeated measures designGeneral MedicineRepeatabilityMiddle AgedLight intensityFemaleSurgerybusiness030217 neurology & neurosurgeryExpert Review of Medical Devices
researchProduct

Evaluation of two instruments of perceived symptom intensity in palliative care patients in an outpatient clinic

2015

Aims and objectives To evaluate the test–retest stability in assessments of perceived symptom intensity on the Edmonton Symptom Assessment System-revised and the European Organization for Research and Treatment of Cancer, Quality of Life Questionnaire Core 15 Palliative. The possible interchangeability between the instruments and the patients’ experiences of completing the instruments were also studied. Background The two instruments assess the same symptoms, but the symptom intensity is assessed on 11-point numerical scales on the Edmonton Symptom Assessment System-revised and on four-point verbal descriptive scales on the European Organization for Research and Treatment of Cancer, Quality…

AdultMalemedicine.medical_specialtyPalliative carePsychometricsSymptom assessmentAmbulatory Care Facilities03 medical and health sciences0302 clinical medicineQuality of life (healthcare)030502 gerontologyRating scaleNeoplasmsSurveys and QuestionnairesHumansMedicineOutpatient clinicGeneral NursingReliability (statistics)AgedSymptom intensityAged 80 and overNorwaybusiness.industryPalliative CareReproducibility of ResultsGeneral MedicineMiddle AgedClinical Practice030220 oncology & carcinogenesisQuality of LifePhysical therapyFemale0305 other medical sciencebusinessJournal of Clinical Nursing
researchProduct

Validation of the German Version of the Quality of Dying and Death Questionnaire for Informal Caregivers (QODD-D-Ang).

2015

Abstract Context The quality of dying and death (QOD) influences end-of-life care for patients and their relatives. To the best of our knowledge, there are currently no validated standard instruments for evaluating the QOD of patients in palliative care units (PCUs) in Germany. Objectives This study aimed to validate the German version of the multidimensional questionnaire "Quality of Dying and Death" for informal caregivers (QODD-Deutsch-Angehorige [QODD-D-Ang]) and provide a detailed report on its validity and reliability. Methods The QODD was forward/backward translated following the European Organization for Research and Treatment of Cancer guidelines. Data collected in two German palli…

AdultMalemedicine.medical_specialtyPalliative carePsychometricsValidityContext (language use)Interviews as TopicYoung AdultCronbach's alphaNursingGermanySurveys and QuestionnairesmedicineHumansTranslationsGeneral NursingReliability (statistics)AgedAged 80 and overbusiness.industryPalliative CareDiscriminant validityReproducibility of ResultsMiddle AgedDeathAnesthesiology and Pain MedicineConvergent validityCaregiversFamily medicineScale (social sciences)FemaleNeurology (clinical)businessJournal of pain and symptom management
researchProduct

Monitoring cognitive changes: Psychometric properties of six cognitive tests

2004

Objectives. Repeated neuropsychological assessments are often used to monitor change in cognitive functioning over time. Thus, knowledge about the reliability and stability of neuropsychological tests and the effects of age and IQ is of paramount importance. In this study we document, for six cognitive tests: test-retest reliabilities, practice effects, reliable change (RC) indices corrected for practice, and the impact of premorbid IQ and age. Design. A sample of 188 normal adults (aged 40-70 years) were administered, on two occasions, one or more of the following tests: the Graded Naming Test (GNT), the Silhouettes Test, two tests of verbal fluency, the Modified Wisconsin Card Sorting Tes…

AdultMalemedicine.medical_specialtyPsychometricsBRAIN-INJURYTest validityNeuropsychological TestsAudiologyNAMING TESTNational Adult Reading TestSeverity of Illness IndexMEMORY TESTDevelopmental psychologyDEMOGRAPHIC-VARIABLESTEST-PERFORMANCEmedicineHumansLONGITUDINAL PROFILESAchievement testVerbal fluency testAgedCARD SORTING TESTSettore M-PSI/02 - Psicobiologia E Psicologia FisiologicaIntelligence quotientmedicine.diagnostic_testReproducibility of ResultsGeneral MedicineNeuropsychological testMiddle AgedCognitive testTest (assessment)ALZHEIMERS-DISEASEVERBAL FLUENCYClinical PsychologyPractice PsychologicalFemaleTEST-RETEST RELIABILITYCognition DisordersPsychologyGraded Naming Test Silhouettes Test Verbal fluency tests Modified Wisconsin Card Sorting Test New Symbol Digit Test National Adult Reading Test (NART)
researchProduct

Quality of Life in Individuals Affected by Arnold Chiari Malformation: Comparison and Validation of a Measurement Instrument.

2017

BACKGROUND Introduction. Arnold Chiari Malformation (ACM) type I is a pathology whose symptomatology has repercussions for the quality of life of those affected by it. Quality-of-life measurement instruments can allow the severity of the impact of Chiari type I malformation on patients' lives to be monitored. The Chiari Symptom Profile (CSP) is a valid and reliable instrument designed for this purpose. The aim of the study was to adapt the CSP to Spanish and to explore the reliability and validity of this construct in the context of Spanish-speaking patients with ACM. METHODS The English CSP instrument has a good internal validity and consistency. We used a standardized procedure for the li…

AdultMalemedicine.medical_specialtyPsychometricsEndocrinology Diabetes and MetabolismHealth StatusContext (language use)Linguistic validation030218 nuclear medicine & medical imagingCorrelation03 medical and health sciences0302 clinical medicineQuality of lifeCronbach's alphaCost of IllnessPredictive Value of TestsSickness Impact ProfileSurveys and QuestionnairesImmunology and AllergyMedicineHumansInternal validityReliability (statistics)business.industryfungiReproducibility of ResultsMiddle AgedTranslatingSyringomyeliaArnold-Chiari MalformationSpainScale (social sciences)Physical therapyQuality of LifeFemalebusiness030217 neurology & neurosurgeryEndocrine, metabolicimmune disorders drug targets
researchProduct