Search results for "LIMIT"

showing 10 items of 2826 documents

Quantification of Regional Intrapulmonary Oxygen Partial Pressure Evolution during Apnea by 3He MRI

1999

We present a new method to determine in vivo the temporal evolution of intrapulmonary oxygen concentrations by functional lung imaging with hyperpolarized (3)Helium ((3)He-->). Single-breath, single-bolus visualization of (3)He--> administered to the airspaces is used to analyze nuclear spin relaxation caused by the local oxygen partial pressure p(O(2))(t). We model the dynamics of hyperpolarization in the lung by rate equations. Based hereupon, a double acquisition technique is presented to separate depolarization by RF pulses and oxygen induced relaxation. It permits the determination of p(O(2)) with a high accuracy of up to 3% with simultaneous flip angle calibration using no additional …

AdultMaleNuclear and High Energy PhysicsApneaSwinePartial PressureBiophysicsAnalytical chemistrychemistry.chemical_elementHyperpolarized Helium 3HeliumBiochemistryOxygenNuclear magnetic resonanceIsotopesFlip angleAnimalsHumansHyperpolarization (physics)LungPhantoms ImagingRelaxation (NMR)DepolarizationPartial pressureCondensed Matter PhysicsMagnetic Resonance ImagingOxygenchemistryLimiting oxygen concentrationJournal of Magnetic Resonance
researchProduct

The PACE study: past-year prevalence of tension-type headache and its subtypes in Parma's adult general population.

2014

The mean global prevalence of tension-type headache (TTH) in adult is 42 %. To date, there have been no Italian studies on TTH prevalence in the adult general population. Therefore, we conducted a cross-sectional study, called PACE, aimed at detecting the prevalence of primary headaches in the city of Parma's adult general population. 904 subjects representative of Parma's adult general population were interviewed face to face by a physician of our Headache Centre. Crude past-year prevalence for definite TTH was 19.4 % (95 % CI 16.8-21.9; 18.4 %, 95 % CI 14.6-22.3 in men, and 20.1 %, 95 % CI 16.6-23.6 in women), namely, 9.0 % (95 % CI 7.1-10.8) for infrequent TTH, 9.8 % (95 % CI 7.9-11.8) f…

AdultMalePediatricsmedicine.medical_specialtyAdolescentCross-sectional studyPopulationPrevalenceDermatologyLower limitInterviews as TopicYoung AdultPrimary headacheSurveys and QuestionnairesHeadache Tension-type headache PrevalencePrevalenceHumansMedicineYoung adulteducationAgedAged 80 and overeducation.field_of_studybusiness.industryTension-Type HeadacheAge FactorsGeneral MedicineMiddle AgedPsychiatry and Mental healthCross-Sectional StudiesItalyFemaleSettore MED/26 - NeurologiaNeurology (clinical)businessDemography
researchProduct

Establishing the upper reference limit of Galectin-3 in healthy blood donors

2017

Introduction Galectin-3 (Gal-3) is an independent predictor of poor outcomes and mortality in patients with heart failure (HF). Thus, it has been proposed as a reliable prognostic biomarker for HF. The definition of reference intervals is mandatory for interpreting the findings of experimental studies and encouraging the routine use of biomarkers in clinical practice. To date, no study assessed the reference intervals of Gal-3 and identified the biological variables that affect its concentration in a well-defined healthy population. The aim of this study was to determine the upper reference limit (URL) of Gal-3 in a highly reliable population of healthy subjects. Materials and methods We re…

AdultMalePercentilemedicine.medical_specialtyBlood donorAdolescentGalectin 3PopulationClinical BiochemistryBlood DonorsHeart failure030204 cardiovascular system & hematologyYoung Adult03 medical and health sciences0302 clinical medicineInternal medicineNatriuretic Peptide BrainmedicineHumansGalectin-3Prognostic biomarkergalectin-3; blood donors; heart failure; reference values; upper reference limit (URL)educationAgedImmunoassayeducation.field_of_studybusiness.industryHealthy populationTroponin IBiochemistry (medical)Healthy subjectsMiddle Agedreference valuesmedicine.diseaseOriginal PapersHealthy VolunteersReference intervals030220 oncology & carcinogenesisHeart failurePopulation studyFemaleUpper reference limit (URL)businessBiomarkersReference valueGlomerular Filtration Rate
researchProduct

Effect of fatigue strength exercise on anterior thigh skin temperature rewarming after cold stress test.

2021

Although dynamic thermography skin temperature assessment has been used in medical field, scientific evidence in sports is scarce. The aim of the study was to assess changes in anterior thigh skin temperature in response to a cold stress test after a strength exercise fatiguing protocol. Ten physically active adults performed a familiarization session and two strength exercise sessions, one with dominant and the other with non-dominant lower limb. Participants performed bouts of 10 concentric and eccentric contractions of leg extensions in an isokinetic device until reaching around 30% of force loss. Infrared thermographic images were taken at baseline conditions and after the fatigue level…

AdultMalePhysiologyVastus medialismedicine.medical_treatmentCryotherapyConcentricBiochemistryYoung AdultMedicineHumansAnterior compartment of thighExerciseCold stressFatiguebusiness.industryCold-Shock ResponseSkin temperatureFatigue limitThighThermographyAnesthesiaThermographyFemaleGeneral Agricultural and Biological SciencesbusinessSkin TemperatureDevelopmental BiologyJournal of thermal biology
researchProduct

Automated Determination of Fluvoxamine in Plasma by Column-Switching High-Performance Liquid Chromatography

1992

Abstract A column-switching system with high-performance liquid-chromatographic separation and ultraviolet detection is described for automated determination of fluvoxamine in human plasma or serum. Samples were injected and the drug was retained in a clean-up column [20 x 4.6 mm (i.d.)] filled with C8 reversed-phase material (10-micron particles). After unwanted material was washed out, the drug was eluted and separated with an analytical chromatography column, 4.6 x 250 mm (i.d.), filled with Nucleosil 100 CN (5-micron particles) with an acetonitrile:methanol:0.01 mol/L phosphate buffer eluent (188:578:235 by vol) at a flow rate of 1.5 mL/min for < 20 min and detected by spectromet…

AdultMaleQuality ControlDetection limitAutoanalysisChromatographyDepressionChemistryElutionBiochemistry (medical)Clinical BiochemistryFluvoxamineMiddle AgedMass spectrometryHigh-performance liquid chromatographyColumn chromatographyFluvoxaminemedicineHumansFemaleChromatography columnQuantitative analysis (chemistry)Chromatography High Pressure LiquidAgedmedicine.drugClinical Chemistry
researchProduct

Automated Determination of Dextromethorphan and Its Main Metabolites in Human Plasma by High-Performance Liquid Chromatography and Column Switching

1996

An automated column-switching technique coupled to isocratic high-performance liquid chromatography (HPLC) with fluorescence detection was developed for simultaneous determination of dextromethorphan and its three major metabolites, dextrorphan, hydroxymorphinan, and methoxymorphinan. After cleavage of conjugates by incubation with glucuronidasearylsulfatase at 37 degrees C for 15 h, plasma samples were injected directly into the HPLC system. Dextromethorphan and metabolites were retained on a cleanup column (10 x 4.6 mm internal diameter [ID]) filled with cyanopropyl (CN) material (Hypersil CPS, 10-microns article size) while interfering proteins and lipids were washed to waste. After colu…

AdultMaleQuality ControlMetaboliteMass spectrometryDextromethorphanHigh-performance liquid chromatographyFluorescence spectroscopychemistry.chemical_compoundDextrorphanmedicineHumansPharmacology (medical)BiotransformationChromatography High Pressure LiquidPharmacologyDetection limitChromatographyElutionDextromethorphanAntitussive AgentsPhenotypeSpectrometry FluorescenceCytochrome P-450 CYP2D6chemistryCalibrationRegression AnalysisFemalemedicine.drugTherapeutic Drug Monitoring
researchProduct

Detection of gamma-hydroxybutyrate in hair: Validation of GC–MS and LC–MS/MS methods and application to a real case

2012

A gas chromatography-mass spectrometry (GC-MS) and a liquid chromatography tandem mass spectrometry (LC-MS/MS) method were validated for quantifying endogenous and exogenous hair concentrations of gamma-hydroxybutyrate (GHB). The GC-MS method is based on overnight extraction of 25 mg hair in NaOH at 56 °C, liquid/liquid extraction in ethylacetate and trimethylsylil derivatization; analysis is by electron ionization and single ion monitoring of three ions. The LC-MS/MS method entails a rapid digestion of 25 mg hair with NaOH at 75 °C for 40 min, liquid/liquid extraction in ethylacetate and reconstitution of the extract in the LC mobile phase; negative ion electrospray ionization and multiple…

AdultMaleQuality ControlSpectrometry Mass Electrospray IonizationSubstance-Related DisordersElectrospray ionizationClinical BiochemistryLiquid-Liquid ExtractionPharmaceutical ScienceAcetatesTandem mass spectrometryMass spectrometryGas Chromatography-Mass SpectrometryAnalytical ChemistryForensic ToxicologySettore MED/43 - Medicina LegaleLiquid chromatography–mass spectrometryLimit of DetectionTandem Mass SpectrometryDrug DiscoveryHumansSodium HydroxideSpectroscopyDetection limitChromatographyChemistryIllicit DrugsSelected reaction monitoringHair Segmental analysis GC–MS LC–MS/MSTemperatureReproducibility of ResultsGamma hydroxybutyrateReference StandardsSubstance Abuse DetectionGamma-hydroxybutyrate GHBCalibrationLinear ModelsCrimeGas chromatography–mass spectrometrySodium OxybateChromatography LiquidHair
researchProduct

Analysis of ecstasy in oral fluid by ion mobility spectrometry and infrared spectroscopy after liquid-liquid extraction.

2014

We developed and evaluated two different strategies for determining abuse drugs based on (i) the analysis of saliva by ion mobility spectrometry (IMS) after thermal desorption and (ii) the joint use of IMS and infrared (IR) spectroscopy after liquid-liquid microextraction (LLME) to enable the sensitivity-enhanced detection and double confirmation of ecstasy (MDMA) abuse. Both strategies proved effective for the intended purpose. Analysing saliva by IMS after thermal desorption, which provides a limit of detection (LOD) of 160μgL(-1), requires adding 0.2M acetic acid to the sample and using the truncated negative second derivative of the ion mobility spectrum. The joint use of IMS and IR spe…

AdultMaleSpectrophotometry InfraredIon-mobility spectrometryInfraredN-Methyl-34-methylenedioxyamphetamineLiquid-Liquid ExtractionThermal desorptionAnalytical chemistryInfrared spectroscopyBiochemistryAnalytical ChemistryIonLiquid–liquid extractionLimit of DetectionHumansSpectroscopySalivaDetection limitChromatographyChemistryIllicit DrugsOrganic ChemistryGeneral MedicineSubstance Abuse DetectionFemaleJournal of chromatography. A
researchProduct

The synthetic cannabinoid 5F-MDMB-PICA: A case series

2020

5F-MDMB-PICA has been detected in products sold on the internet as well as in biological samples since 2016. It is associated with serious adverse health and behavioral effects and even death. Herein we report on twelve cases with proven 5F-MDMB-PICA consumption, including three fatalities, four cases of driving under the influence of drugs and five other criminal acts. In these cases, 5F-MDMB-PICA was detected in postmortem blood or serum. Concentrations ranged from 0.1-16ng/mL. In some blood (serum) and urine samples, the hydrolysis metabolite of 5F-MDMB-PICA (M12) could also be detected. In this case series, co-consumption with other drugs occurred in 9 of 12 cases, most commonly alcohol…

AdultMaleSubstance-Related Disordersmedicine.medical_treatmentPhysiology01 natural sciencesMass SpectrometryPathology and Forensic Medicine03 medical and health sciences0302 clinical medicineLimit of DetectionPupil DisordersSynthetic cannabinoidsmedicineHumans030216 legal & forensic medicinePica (disorder)ConfusionAdverse effectDriving Under the InfluencePostural BalanceDriving under the influenceSlurred speechMolecular StructurebiologyCannabinoidsIllicit DrugsMood Disordersbusiness.industrySolid Phase Extraction010401 analytical chemistrycelebritiesPostmortem bloodMiddle Agedbiology.organism_classification0104 chemical sciencesAggressioncelebrities.reason_for_arrestSensation DisordersFemaleCrimeCannabinoidCannabismedicine.symptombusinessConjunctivaLawChromatography Liquidmedicine.drugForensic Science International
researchProduct

Concentrations of  9-Tetrahydrocannabinol and 11-Nor-9-Carboxytetrahydrocannabinol in Blood and Urine After Passive Exposure to Cannabis Smoke in a C…

2010

Cannabinoid concentrations in blood and urine after passive exposure to cannabis smoke under real-life conditions were investigated in this study. Eight healthy volunteers were exposed to cannabis smoke for 3 h in a well-attended coffee shop in Maastricht, Netherlands. An initial blood and urine sample was taken from each volunteer before exposure. Blood samples were taken 1.5, 3.5, 6, and 14 h after start of initial exposure, and urine samples were taken after 3.5, 6, 14, 36, 60, and 84 h. The samples were subjected to immunoassay screening for cannabinoids and analyzed using gas chromatography-mass spectrometry (GC-MS) for Delta(9)-tetrahydrocannabinol (THC), 11-nor-hydroxy-Delta(9)-tetra…

AdultMaleTime FactorsHealth Toxicology and Mutagenesismedicine.medical_treatmentEnzyme-Linked Immunosorbent AssayUrineToxicologyGas Chromatography-Mass SpectrometryAnalytical ChemistryPharmacokineticsLimit of DetectionSmokemental disordersmedicineHumansEnvironmental ChemistryDronabinolSolid phase extractionVolunteerCannabisNetherlandsInhalation exposureInhalation ExposureChemical Health and SafetyChromatographymedicine.diagnostic_testChemistryorganic chemicalsReproducibility of ResultsMiddle AgedAir Pollution IndoorImmunoassayFemaleCannabinoidGas chromatography–mass spectrometryJournal of Analytical Toxicology
researchProduct