Search results for "LIMIT"
showing 10 items of 2826 documents
Application of a low transition temperature mixture for the dispersive liquid–liquid microextraction of illicit drugs from urine samples
2021
© 2021 by the authors.
Combined heterologies for monoclonal antibody-based immunoanalysis of fluxapyroxad
2018
Nowadays, instrumental methodologies and rapid bioanalytical techniques complement each other for the analysis of toxic chemical compounds. Fluxapyroxad was commercialized a few years ago as a fungicide and today it is being used worldwide to control a variety of pests. In the present study, the development of monoclonal antibody-based immunochemical methods for the analysis of this chemical in food samples was evaluated for the first time. Novel haptens were synthesized and protein bioconjugates were prepared. High-affinity and specific monoclonal antibodies to fluxapyroxad were generated from two haptens with alternative linker tethering sites. Haptens with linker site heterology and a st…
Combination of supported liquid membrane and solid-phase extraction for sample pretreatment of triazine herbicides in juice prior to capillary electr…
2002
A possibility of a combination of supported liquid membrane (SLM) and solid-phase extraction (SPE) for the determination of atrazine at microgram level in different type of fruit juices is presented. In comparison to SPE extraction from juice samples, the application of SLM-SPE enrichment provides much cleaner extracts and the possibility of lowering the limit of detection as low as 30 microg/l. However, it was also shown that by appropriate manipulation of SLM extraction conditions mainly flow-rate of donor phase and volume ratio between donor and acceptor phase, the level of detection can be further decreased to 10 microg/l. The results suggest that the application of SLM extraction prior…
A solid device based on doped hybrid composites for controlling the dosage of the biocide N-(3-aminopropyl)-N-dodecyl-1,3-propanediamine in industria…
2015
A colorimetric composite device is proposed to determine the widely used biocide N-(3-aminopropyl)-N-dodecyl-1,3-propanediamine (ADP).This sensing device is based on a film of 1,2-Naphthoquinone-4-sulfonate (NQS) embedded into polydimethylsiloxane-tetraethylortosilicate-SiO2 nanoparticles composite (PDMS-TEOS-SiO2NPs). Semiquantitative analysis can be performed by visual inspection. Digitalized image or diffuse reflectance (DR) measurements can be carried out for quantitative analysis. Satisfactory detection limit (0.018%, w/v) and relative standard deviations <12% were achieved. The proposed device has been applied for the determination of ADP in detergent industrial formulations with reco…
A sustainable on-line CapLC method for quantifying antifouling agents like irgarol-1051 and diuron in water samples: Estimation of the carbon footpri…
2016
In this work, in-tube solid phase microextraction (in-tube SPME) coupled to capillary LC (CapLC) with diode array detection has been reported, for on-line extraction and enrichment of booster biocides (irgarol-1051 and diuron) included in Water Frame Directive 2013/39/UE (WFD). The analytical performance has been successfully demonstrated. Furthermore, in the present work, the environmental friendliness of the procedure has been quantified by means of the implementation of the carbon footprint calculation of the analytical procedure and the comparison with other methodologies previously reported. Under the optimum conditions, the method presents good linearity over the range assayed, 0.05-1…
A miniaturized method for estimating di(2-ethylhexyl) phthalate in bivalves as bioindicators.
2012
This work has developed a miniaturized method based on matrix solid phase dispersion (MSPD), using C18 as dispersant and acetonitrile-water as eluting solvent, for the analysis of di(2-ethylhexyl) phthalate (DEHP) in biota samples by capillary liquid chromatography coupled to in-tube solid phase microextraction and diode array detection. Recovery studies showed that the combination of C18-Florisil® was optimal using low amount of samples (0.1 g) and with low volumes of acetonitrile-water (2.6 mL 1:3.25, v/v). The sample is processed in less than 30 min, no evaporation step is required. The proposed method was applied to the analysis of DEHP in mussels and of the coastal waters in which they…
Organic residues in lake and drinking water from the lagoa de Juturnaíba (região dos lagos - RJ, Brazil)
1997
Various analytical methods for the determination of organic residues in water were applied to samples from the Lagoa de Juturnaíba in the Região dos Lagos, east of Rio de Janeiro. The concentrations of more than 60 pesticides and of different aminopolycarboxylic acids were determined using GC/MS detection, and a GC/MS screening procedure was applied to detect additional compounds. None of the investigated pesticide residues could be detected in the lake water at detection limits of less than 100 ng/L. EDTA was detected at a concentration level of 2 mg/L in the lake and in drinking water prepared from this lake. Traces of biphenyl were identified by GC/MS in the lake water, the source of whi…
Low light level in vitro monitoring of cellular and antigen-antibody reactions using a photon detection camera system — New perspectives for clinical…
1990
This article briefly describes the use of a photon counting system (ARGUS-100) in the detection of low levels of light. The ARGUS-100 was used in determining ATP in cell sections from tumor tissues and in measuring a luminescence-enhanced immunoluminometric assay, using ferritin as the analyte, based on the luminol-peroxide-4-iodophenol reaction with peroxidase as the enzyme. The aim is not so much the presentation of data, but rather to show the potentials of the photon counting camera in increasing our knowledge of the cellular and subcellular levels, as well as lowering the detection limits in already sensitive systems, such as immunoassays.
Plasma glycosphingolipids in diabetics and normals
1975
In diabetic patients with hyperlipoproteinemia type IV the monohexosyl ceramide concentration in blood plasma is significantly elevated. This augmentation can be attributed to an increased monohexosyl ceramide content of the BLDL plasma fraction. In contrast, the di-, tri-, the tetrahexosyl ceramide levels remain within normal limits. In normolipidemic diabetics of comparable age, sex, and weight classes and of comparable metabolic control no elevations of glycolipid fractions could be found. However, patients with primary hyperlipoproteinemia type IV show an increase of monohexosyl ceramide concentrations in blood plasma. Therefore, the augmentation of monohexosyl ceramide levels in plasma…
Effect of three-body forces on response functions in infinite neutron matter
2015
International audience; We study the impact of three-body forces on the response functions of cold neutron matter. These response functions are determined in the random phase approximation (RPA) from a residual interaction expressed in terms of Landau parameters. Special attention is paid to the non-central part, including all terms allowed by the relevant symmetries. Using Landau parameters derived from realistic nuclear two- and three-body forces grounded in chiral effective field theory, we find that the three-body term has a strong impact on the excited states of the system and in the static and long-wavelength limit of the response functions for which a new exact formula is established.