Search results for "LIMIT"

showing 10 items of 2826 documents

Vapor-phase introduction of alkyltin compounds in atomic absorption spectrophotometry

1990

Abstract Different systems for the introduction of alkyltin compounds in atomic absorption spectrophotometry using the vapor-phase introduction approach have been compared. Samples and standards were introduced in both quartz cell and flame atomizer using a vertical and a horizontal reactor. The better sensitivity was obtained with the quartz cell and the horizontal reactor.

Detection limitVolatilisationlawChemistryVapor phaseAnalytical chemistryTrace analysisAtomic absorption spectroscopyQuartzSpectroscopyAnalytical Chemistrylaw.inventionMicrochemical Journal
researchProduct

Zinc removal in anaerobic sulphate-reducing liquid substrate process

2002

Abstract Zinc and sulphate removal from synthetic wastewater was investigated by using four laboratory parallel upflow-mode reactors (referred as R1 to R4; R1 contained carriers to retain biomass, whereas R2–R4 were operated as suspended reactors). All reactors were inoculated with anaerobically digested cow manure. R1 and R2 were first fed with glucose- and sulphate-containing feed for 48 days after which all four reactors were fed with wastewater containing 50 mg l−1 of zinc in R1–R3 and 200 mg l−1 in R4 and operated for 96 days. In all reactors, hydraulic retention time, organic loading rate, and sulphate load were 5–6 d, 0.2–0.4 kg COD m−3 d−1 and 3.3–3.8 g SO4 l−1 d−1, respectively, wh…

Detection limitWaste managementHydraulic retention timeMechanical Engineeringchemistry.chemical_elementSubstrate (chemistry)General ChemistryZincGeotechnical Engineering and Engineering GeologyPulp and paper industrychemistry.chemical_compoundWastewaterchemistryControl and Systems EngineeringSulfateEffluentCow dungMinerals Engineering
researchProduct

Online Solid-Phase Extraction LC-MS/MS: A Rapid and Valid Method for the Determination of Perfluorinated Compounds at Sub ng·L-1Level in Natural Water

2018

In this research paper, we report a method able to detect perfluorinated compound at pg·L−1 levels in superficial and underground water samples. An online solid phase extraction HPLC-MS/MS method was developed for the analysis of 12 perfluoroalkyl acids (PFASs). The method is based on injection of 5000 µL of water sample in SPE online WAX column followed by chromatography separation and mass spectrometry determination. SPE online elution was performed by water + 0.05% NH4OH and methanol + 0.05% NH4OH, while separation of target compounds was achieved within 10 min by Gemini chromatographic column operating from 1 to 12 pH range and using a mixture of water-methanol + 0.05% NH4OH. Sub ng·L−1…

Detection limitWaxChromatographyArticle SubjectElution010401 analytical chemistryChemistry (all)Perfluorinated compoundGeneral Chemistry010501 environmental sciencesMass spectrometry01 natural sciences0104 chemical scienceslcsh:Chemistrychemistry.chemical_compoundchemistrylcsh:QD1-999visual_artLc ms msvisual_art.visual_art_mediumSolid phase extractionQuantitative analysis (chemistry)0105 earth and related environmental sciences
researchProduct

Derivative Fourier transform infrared spectrometric determination of ethanol in alcoholic beverages

1994

Abstract A derivative Fourier transform infrared (FT-TR) spectrometric procedure was developed for the direct determination of ethanol in alcoholic beverages, from beers to spirit samples. The method is based on first-order derivative FT-IR measurements between the peak at 1052 cm −1 and the valley at 1040 cm −1 , which are present in aqueous solutions and alcoholic beverages, by using a micro flow transmittance cell with ZnSe windows and a spacer of 0.029 mm. The method involves the accumulation of ten scans and provides accurate results in the determination of ethanol in alcoholic beverages without requiring any previous chemical treatment of the sample or a previous separation or extract…

Detection limitWineAqueous solutionChromatographyEthanolExtraction (chemistry)Analytical chemistryInfrared spectroscopyDerivativeBiochemistryAnalytical Chemistrysymbols.namesakechemistry.chemical_compoundFourier transformchemistrysymbolsEnvironmental ChemistrySpectroscopyAnalytica Chimica Acta
researchProduct

Moiety and linker site heterologies for highly sensitive immunoanalysis of cyprodinil in fermented alcoholic drinks

2015

Cyprodinil is a new-generation anilinopyrimidine fungicide widely used in crop protection and frequently found in fruits. In this study, novel derivatives of cyprodinil with linker site heterologies were synthesized and employed in order to produce antibodies with enhanced affinity. Moreover, moiety-heterologous haptens were designed and prepared for assay sensitivity improvement. Two competitive enzyme-linked immunosorbent assays for the analysis of this active substance were developed using direct and indirect formats, achieving IC50 values around 0.15 μg/L. Analytical figures of merit and usability of the optimized assays were evaluated with wine and cider as model food processed matrice…

Detection limitWineHapten designChromatographyChemistryFood analysisFungicideWineAssay sensitivityHighly sensitiveCidersMoietyFermentationELISAHaptenLinkerFood ScienceBiotechnology
researchProduct

Supercritical fluid extraction of resveratrol from grape skin of Vitis vinifera and determination by HPLC

2000

Supercritical fluid extraction of resveratrol from grape skin of Vitis vinifera was studied. Extraction variables such pressure, modifier concentration (ethanol), and extraction time were optimised. Final extraction conditions were: 40 degrees C, 150 bar, 7.5% ethanol and extraction time 15 min. Extraction recovery and precision (variation coefficient between 0.2 and 1.0%) were calculated. The resveratrol content in the ethanolic extract was determined by HPLC with UV detection at 306 nm. Acetic acid-methanol-water was used as the mobile phase, and C-18 and C-8 columns were tested, instrumental parameters were optimised, and analytical parameters were calculated (lineal interval 0-75 mg l(-…

Detection limitWinechemistry.chemical_compoundChromatographychemistryCoefficient of variationExtraction (chemistry)Supercritical fluid extractionResveratrolHigh-performance liquid chromatographyQuantitative analysis (chemistry)Analytical ChemistryTalanta
researchProduct

Quantifying both ammonium and proline in wines and beer by using a PDMS composite for sensoring.

2019

Abstract Two of the reagents involved in the Berthelot's reaction, thymol and nitroprusside, were embedded in a PDMS composite in order to apply this assay to determine ammonium and proline, in wine and beers. Safety, portability, rapidity, cost-effectiveness and simplicity of the assay were improved. For the proline determination, a modified Berthelot's reaction, which included a ring cleavage of proline, was optimized. The accuracy of the assay was tested. The limits of detection for ammonium was 0.12 µg mL−1 and for proline was in the range from 0.7 to 4.1 µg mL−1, depending on the kind of wine (white, red, or sweet), for beer the LOD was 6 µg mL−1. The precision achieved was slower than…

Detection limitWinechemistry.chemical_compoundValidation studyChromatographychemistryReagentComposite numberfood and beveragesAmmoniumProlineThymolAnalytical ChemistryTalanta
researchProduct

Analysis of insoluble silicate: Decomposition with molten sodium hydroxide and determination of Zr(IV) with chloranilic acid in medium-strong acid

1983

A rapid, accurate and precise method for the determination of zirconium in silicates is proposed. Insoluble or sparingly soluble samples are decomposed by means of molten sodium hydroxide. Chloranilic acid is employed as reagent for the spectrophotometric determination of Zr(IV). The limit of detection is 1.2×10−7 M and the relative standard deviation is 0.24%.

Detection limitZirconiumClinical BiochemistryRelative standard deviationInorganic chemistrychemistry.chemical_elementGeneral MedicineDecompositionSilicateAnalytical Chemistrychemistry.chemical_compoundchemistryChloranilic acidSodium hydroxideReagentGeneral Materials ScienceFresenius' Zeitschrift für analytische Chemie
researchProduct

Determination of glyphosate and aminomethylphosphonic acid in natural water using the capillary electrophoresis combined with enrichment step

2005

A previously elaborated capillary electrophoresis (CE) method used for the determination of glyphosate and aminomethylphosphonic acid (AMPA) was slightly modified in order to improve the sensitivity. However, detection limits attained (5 μg mL−1 for glyphosate and 4 μg mL−1 for AMPA) were still not satisfactory for analytical purposes, thus the addition of a preconcentration step before the CE analysis was proposed. AMBERLITE®IRA-900, a strong anion-exchange resin, was used to preconcentrate both analytes in environmental aqueous samples. The experimental conditions optimised in a previous work were readapted, by decreasing the eluent concentration due to CE limitations. Satisfactory result…

Detection limitaminomethylphosphonic acid (AMPA)Chromatographyanion-exchange resinsChemistrycapillary electrophoresisBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundColumn chromatographyCapillary electrophoresisglyphosateGlyphosateenvironmental analysisUltrapure waterEnvironmental ChemistryAminomethylphosphonic acidSample preparationHPLCSpectroscopyAnalytica Chimica Acta
researchProduct

Major and Trace Element Geochemistry of the European Kupferschiefer – An Evaluation of Analytical Techniques

2018

Simple and rapid techniques are needed for routine quantitative chemical bulk-rock analyses of Kupferschiefer, a black shale containing variable amounts of silicates, base metal sulphides, carbonates and an organic content of up to 30 weight percent. In this study, WD-XRF, TXRF, and ICP-OES of acid- as well as peroxide-digested samples were tested as potential techniques based on their availability and adaptability to analyse major (Si, Ti, Al, Mg, Ca, Fe, K, but also Cu, Zn, Pb) and selected trace (Ag, As, Ba, Co, Mo, Ni, V) element concentrations. Because of the absence of a suitable reference material, a comparative study was undertaken using instrumental neutron activation analysis to a…

Detection limitblack shaleIsotopeChemistryTrace elementAnalytical chemistrysulphidescopper oresGeneral Chemistry010501 environmental sciences010502 geochemistry & geophysics01 natural scienceswhole-rock geochemistryDigestion (alchemy)Geochemistry and PetrologyWD-XRFICP-OESGeneral Earth and Planetary SciencesINAANeutron activation analysisOil shaleMass fractionBase metal0105 earth and related environmental sciencesGeneral Environmental Science
researchProduct