Search results for "Lait"
showing 10 items of 683 documents
Formulation, process conditions, and biological evaluation of dairy mixed gels containing fava bean and milk proteins: Effect on protein retention in…
2019
International audience; Food formulation and process conditions can indirectly influence AA digestibility and bioavailability. Here we investigated the effects of formulation and process conditions used in the manufacture of novel blended dairy gels (called "mixed gels" here) containing fava bean (Vicia faba) globular proteins on both protein composition and metabolism when given to young rats. Three mixed dairy gels containing casein micelles and fava bean proteins were produced either by chemical acidification (A) with glucono-δ-lactone (GDL) or by lactic acid fermentation. Fermented gels containing casein and fava bean proteins were produced without (F) or with (FW) whey proteins. The AA…
Whey proteins are more efficient than casein in the recovery of muscle functional properties following a casting induced muscle atrophy.
2013
International audience; The purpose of this study was to investigate the effect of whey supplementation, as compared to the standard casein diet, on the recovery of muscle functional properties after a casting-induced immobilization period. After an initial (I0) evaluation of the contractile properties of the plantarflexors (isometric torque-frequency relationship, concentric power-velocity relationship and a fatigability test), the ankle of 20 male adult rats was immobilized by casting for 8 days. During this period, rats were fed a standard diet with 13% of casein (CAS). After cast removal, rats received either the same diet or a diet with 13% of whey proteins (WHEY). A control group (n =…
Evaluation of nocturnal vs. morning measures of heart rate indices in young athletes
2022
Purpose The purpose of this study was to compare heart rate (HR) and heart rate variability in young endurance athletes during nocturnal sleep and in the morning; and to assess whether changes in these values are associated with changes in submaximal running (SRT) and counter-movement jump (CMJ) performance. Methods During a three-week period of similar training, eleven athletes (16 ± 1 years) determined daily HR and heart rate variability (RMSSD) during sleep utilizing a ballistocardiographic device (Emfit QS), as well as in the morning with a HR monitor (Polar V800). Aerobic fitness and power production were assessed employing SRT and CMJ test. Results Comparison of the average values fo…
Superconductor-ferromagnet tunnel junction thermoelectric bolometer and calorimeter with a SQUID readout
2020
Superconductor-ferromagnet thermoelectric detector (SFTED) is a novel ultrasensitive radiation detector based on the giant thermoelectric effect in superconductor-ferromagnet tunnel junctions. This type of detector can be operated without the need of additional bias lines, and is predicted to provide a performance rivaling transition-edge sensors and kinetic inductance detectors. Here we report our numerical studies on the SFTED noise equivalent power, energy resolution and time constant, and the feasibility of a SQUID readout in both bolometric and calorimetric regimes, with the goal to provide practical design parameters for the detector fabrication and the readout circuitry implementatio…
Radioactive ion beam manipulation at the IGISOL-4 facility
2020
The IGISOL-4 facility in the JYFL Accelerator Laboratory of the University of Jyvaskyla (JYFL-ACCLAB) produces low-energy radioactive ion beams, primarily for nuclear spectroscopy, utilizing an ion guide-based, ISOL-type mass separator. Recently, new ion manipulation techniques have been introduced at the IGISOL-4 including the application of the PI-ICR (Phase-Imaging Ion Cyclotron Resonance) technique at the JYFLTRAP Penning trap, as well as commissioning of a Multi-Reflection Time-Of-Flight (MR-TOF) separator/spectrometer. The successful operation of the MR-TOF also required significant improvement of the Radio-Frequency Quadrupole (RFQ) cooler and buncher device beam pulse time structure…
Laitoksissa asuvien vanhusten aliravitsemus
2000
Sääksmäen ja Hollolan kihlakuntien rajakiista
1733
Universal Gravitation and the (Un)Intelligibility of Natural Philosophy
2019
This article centers on Hume's position on the intelligibility of natural philosophy. To that end, the controversy surrounding universal gravitation shall be scrutinized. It is very well known that Hume sides with the Newtonian experimentalist approach rather than with the Leibnizian demand for intelligibility. However, what is not clear is Hume's overall position on the intelligibility of natural philosophy. It shall be argued that Hume declines Leibniz's principle of intelligibility. However, Hume does not eschew intelligibility altogether; his concept of causation itself stipulates mechanical intelligibility. peerReviewed
Oral manifestations of Type I Neurofibromatosis in a family
2011
Neurofibroma is a benign peripheral nerve sheath tumor. It is one of the most frequent tumors of neural origin and its presence is one of the clinical criteria for the diagnosis of neurofibromatosis type I (NF-I). Neurofibromatosis type I is an autosomal dominantly inherited disease due to an alteration in the long arm of chromosome 17. About 50% of NF-I patients have no family history of the disease. NF-I patients have skin lesions (café au lait spots and neurofibromas) as well as bone malformations and central nervous system tumors. Diagnosis is based on a series of clinical criteria. NF-I presents with certain definite oral manifestations which confers to the dentists a major responsibil…
Fission studies at IGISOL/JYFLTRAP: Simulations of the ion guide for neutron-induced fission and comparison with experimental data
2020
For the production of exotic nuclei at the IGISOL facility, an ion guide for neutron-induced fission has been developed and tested in experiments. Fission fragments are produced inside the ion guide and collected using a helium buffer gas. Meanwhile, a GEANT4 model has been developed to simulate the transportation and stopping of the charged fission products. In a recent measurement of neutron-induced fission yields, implantation foils were located at different positions in the ion guide. The gamma spectra from these foils and the fission targets are compared to the results from the GEANT4 simulation. In order to allow fission yield measurements in the low yield regions, towards the tails a…