Search results for "Leak"
showing 10 items of 244 documents
Individual surgeon is an independent risk factor for leak after double-stapled colorectal anastomosis: An institutional analysis of 800 patients
2017
Background. Our aim was to assess whether the individual surgeon is an independent risk factor for anastomotic leak in double-stapled colorectal anastomosis after left colon and rectal cancer resection. Methods. This retrospective analysis of a prospectively collected database consists of a consecutive series of 800 patients who underwent an elective left colon and rectal resection with a colorectal, double-stapled anastomosis between 1993 and 2009 in a specialized colorectal unit of a tertiary hospital with 7 participating surgeons. The main outcome variable was anastomotic leak, defined as leak of luminal contents from a colorectal anastomosis between 2 hollow viscera diagnosed radiologic…
Pressure-decay testing of pleural air leaks in intact murine lungs: evidence for peripheral airway regulation.
2018
Abstract The critical care management of pleural air leaks can be challenging in all patients, but particularly in patients on mechanical ventilation. To investigate the effect of central airway pressure and pleural pressure on pulmonary air leaks, we studied orotracheally intubated mice with pleural injuries. We used clinically relevant variables – namely, airway pressure and pleural pressure – to investigate flow through peripheral air leaks. The model studied the pleural injuries using a pressure‐decay maneuver. The pressure‐decay maneuver involved a 3 sec ramp to 30 cmH20 followed by a 3 sec breath hold. After pleural injury, the pressure‐decay maneuver demonstrated a distinctive airway…
A New Model of Skull Base Reconstruction following Expanded Endonasal or Transoral Approaches – Long-Term Results in Primates
2007
<i>Objective:</i> The direct endonasal or transoral transclival approaches to the skull base permit effective minimally invasive surgery along the clivus region. Developing consistently effective techniques to prevent cerebrospinal fluid (CSF) leaks and their consequences (infections and healing processes with long and complicated recoveries) remains a major challenge. In this study, we tested over a long period a method of bone reconstruction newly developed by us, which makes use of a specially designed elastic silicone plug that can be employed for bone replacement after minimally invasive skull base surgery without risk of postoperative CSF leaks. After acute testing of plug…
Prophylactic Percutaneous Sealing of Lumbar Postdural Puncture Hole with Fibrin Glue to Prevent Cerebrospinal Fluid Leakage in Swine
2000
UNLABELLED We explored the effect of fibrin glue injection at the site of dural puncture on cerebrospinal fluid (CSF) leakage in a swine model. Pigs were subjected to a lumbar dural CSF puncture in the sitting position with a 17-gauge Tuohy needle. Fibrin glue 1.4 mL was injected through the same needle into the epidural space. Evans blue dye was infused through the cisterna magna 15 min later, and the appearance of dyed CSF through the skin puncture and along the needle trajectory to the dura was inspected and categorized. In seven of eight animals, the CSF leak was sealed with fibrin glue. Control animals were injected with 1.4 mL saline. A sham operation group of animals underwent cister…
Three-Dimensional Analysis of Component Stability of the Nellix Endovascular Aneurysm Sealing System After Treatment of Infrarenal Abdominal Aortic A…
2016
Purpose: To assess short-term stability and conformational changes of the Nellix EndoVascular Aneurysm Sealing (EVAS) System using 3-dimensional (3D) analysis. Methods: Postoperative computed tomography (CT) scans obtained at 0, 3, and 12 months in 24 patients (mean age 75±7 years; 22 men) who underwent EVAS between December 2013 and December 2014 for intact abdominal aortic aneurysm (within the instructions for use) were evaluated for stent-graft deviation in multiple planes using dedicated 3D analysis software. In addition, 2D analysis using an anatomically fixed reference landmark was performed to assess craniocaudal migration. Clinical and follow-up data of the patients were recorded a…
Impact of perioperative transfusions and sepsis on long-term oncologic outcomes after curative colon cancer resection. A retrospective analysis of a …
2020
Objective: Intra-abdominal septic complications (IASC) affect short-term outcomes after surgery for colon cancer. Blood transfusions have been associated with worse short-term results.The role of IASC and blood transfusions on long-term oncologic results is still debated. This study aims to assess the impact of these two variables on survival after curative colon cancer resection. Patients and methods: Retrospective analysis of a prospectively maintained database of patients who underwent curative surgery for colon cancer at a university hospital, between 1993 and 2010. Cox regression was used to identify the role of IASC and transfusions (alone and combined) on local recurrence (LR), disea…
Use of covered chimney stents for pararenal aortic pathologies is safe and feasible with excellent patency and low incidence of endoleaks.
2012
Background To present the clinical experience of consecutive series with use of balloon-expandable and self-expanding chimney endografts (balloon-expandable covered stent group [BECS] vs self-expanding covered stent group [SECS]) in the endovascular treatment of challenging aortic pathologies requiring renal and/or visceral revascularization. Methods Between January 2009 and May 2011, data for 37 high-risk patients from one center and 35 patients from another institution, with pararenal aortic pathologies treated by the chimney endovascular technique, were prospectively collected. The chimney-graft technique is based on the deployment of a covered or bare-metal stent parallel to the aortic …
CT Angiography at 24 Months Demonstrates Durability of EVAR With the Use of Chimney Grafts for Pararenal Aortic Pathologies
2013
PURPOSE: To present the 24-month radiological follow-up data for patients with pararenal aortic pathologies treated with chimney and periscope grafts during endovascular repair. METHODS: Between January 2008 and December 2011, 124 high-risk patients with complex pararenal aortic pathologies were treated using the chimney technique at 2 European vascular and cardiovascular centers with advanced experience of the described technique. In particular, 50 patients were treated at Site 1 and 74 at Site 2. Forty (32.2%) patients (32 men; mean age 79.2±4.9 years) completed computed tomographic angiography follow-up at 24 months postoperatively. RESULTS: The overall technical success was 100%, and th…
Pringle maneuver increases the risk of anastomotic leakage after colonic resection in rats.
2018
Abstract Background Many centers use the Pringle's maneuver during liver resections. Since this maneuver might impair healing of bowel anastomoses, we evaluated its influence on the healing of colonic anastomosis in rats. Methods Male Wistar rats underwent median laparotomy and sigmoid resection with end-to-end anastomosis under inhalation anesthesia. Thereafter, rats received a 25 minutes Pringle's maneuver (PM, group 1) or were kept under anesthesia for the same period of time (group 2). The anastomotic bursting pressure (BP) was measured on postoperative days (POD) 3, 6 and 9. Hematoxylin and Eosin (H&E) staining was used for histopathological evaluation of the anastomosis. The Mann-Whit…
Surgical conversion with graft salvage as a definitive treatment for persistent type II endoleak causing sacenlargement
2015
Objective The goal of this study was to present open surgical conversion with graft salvage or "semiconversion" as a definitive and safe treatment for untreatable and persistent type II endoleaks causing sac enlargement after endovascular aneurysm repair. Methods Between January 2001 and December 2014, 25 of 1623 endovascular aortic repair (EVAR) patients were selected as candidates for open semiconversion. The indication was persistent type II endoleak in 13 patients (12 of whom received previous attempts of embolization), type I and II endoleak in 2 patients, and sac growth without imaging evidence of endoleak in the other 10. After the infrarenal aorta was prepared (via a retroperitoneal…