Search results for "Leak"

showing 10 items of 244 documents

The effect of oxygenation on the radiation hardness of silicon studied by surface photovoltage method

2002

The effect of oxygenation on the radiation hardness of silicon detectors was studied. Oxygen-enriched and standard float-zone silicon pin-diodes and oxidized samples were processed and irradiated with 15-MeV protons. After the irradiations, the surface photovoltage (SPV) method was applied to extract minority carrier diffusion lengths of the silicon samples. Adding oxygen to silicon was found to improve the radiation hardness of silicon. The effect was visible in minority carrier diffusion lengths as well as in reverse bias leakage currents. The suitability of SPV method for characterizing irradiated silicon samples was proved.

inorganic chemicalsNuclear and High Energy PhysicsMaterials scienceSiliconPhysics::Instrumentation and Detectorsbusiness.industrySurface photovoltageDetectortechnology industry and agriculturechemistry.chemical_elementCarrier lifetimeequipment and suppliescomplex mixturesOxygenstomatognathic diseasesNuclear Energy and EngineeringchemistryOptoelectronicsIrradiationElectrical and Electronic EngineeringbusinessRadiation hardeningLeakage (electronics)IEEE Transactions on Nuclear Science
researchProduct

Design and development of safety and control systems in ATLAS

2021

El gran colisionador de hadrones, o LHC, es el acelerador de partículas más grande y potente del mundo. Ha sido construido por el CERN, la Organización Europea para la Investigación Nuclear, entre 1998 y 2008 en Ginebra, Suiza. Sucesivas mejoras en el LHC supondrán a partir de mediados del 2027 un incremento de la luminosidad, cuando pasará a llamarse High Luminosity LHC (HL-LHC). Esta tesis se divide en dos partes, por una parte la seguridad y operación de la infraestructura y por otra los sistemas de control y toma de datos. La primera parte de la tesis se dedica a la seguridad y operación de la infraestructura. Después de más de 10 años de funcionamiento, el riesgo de posibles fallos en …

leak detectionhadiation hardness:CIENCIAS TECNOLÓGICAS [UNESCO]CMOSexpert systemsLHCDetectors and Experimental TechniquesATLASUNESCO::CIENCIAS TECNOLÓGICASbeam telescopeSEU
researchProduct

Electrochemical Oxidation of Hf-Nb Alloys as a Valuable Route to Prepare Mixed Oxides of Tailored Dielectric Properties

2018

Metal oxides with high dielectric constant are extensively studied in the frame of substituting SiO2 as gate dielectric in nanoelectronic devices. Here, high-k mixed HfO2/Nb2O5 oxides are prepared by a facile electrochemical route starting from sputtering-deposited Hf–Nb alloys with several compositions. Transmission electron microscopy, grazing incidence X-ray diffraction, and glow discharge optical emission spectroscopy are employed to study the oxide structures, disclosing a crystalline–amorphous transition of the electrochemically prepared oxides by increasing the Nb content. Photo-electrochemical measurements allow the observation of optical transitions ascribed to localized states ins…

leakage currentImaginationThesaurus (information retrieval)Materials scienceChemical substanceEOTmedia_common.quotation_subjectNanotechnologyhigh-k material02 engineering and technologyDielectric010402 general chemistry021001 nanoscience & nanotechnologyElectrochemistry01 natural sciences0104 chemical sciencesElectronic Optical and Magnetic MaterialsSearch engineElectrochemical oxidationSettore ING-IND/23 - Chimica Fisica ApplicataHf oxide0210 nano-technologyScience technology and societymedia_commonAdvanced Electronic Materials
researchProduct

Effectiveness and quality of life 10 years after transobturator suburethral tape surgery for stress urinary incontinence

2018

AIM We aimed to measure the effectiveness and quality of life (QoL) 10 years after transobturator suburethral tape surgery. METHODS We carried out a prospective observational study of 42 women assessed 10 years after surgical intervention with the transobturator technique. The main outcome measures were subjective and objective cure or improvement, complications, and changes in QoL. RESULTS The median abdominal leak point pressure had been 92 (82-113) mL H2 O prior to surgery. Thirty-six women (85.7%) remained cured (negative cough test) and 13 (31%) reported urine leakage during physical activity, percentages which were similar to those at a previous assessment at the 5th year. Urgency uri…

medicine.medical_specialty030219 obstetrics & reproductive medicinebusiness.industryGenitourinary system030232 urology & nephrologyObstetrics and GynecologyUrinary incontinenceLeak point pressureSurgery03 medical and health sciencesDistress0302 clinical medicineQuality of lifemedicineObservational studymedicine.symptomUrgency incontinenceTransobturator Suburethral TapebusinessJournal of Obstetrics and Gynaecology Research
researchProduct

Type 1A endoleak detachable coil embolization after endovascular aneurysm sealing: Case report

2021

Introduction Endovascular aneurysm sealing (EVAS) with the Nellix system was introduced to reduce endovascular aneurysm repair (EVAR) perioperative complications, especially endoleaks. Herein we report a case of successful type 1A endoleak managed with detachable coils embolization after EVAS. Presentation of case A 77-year-old male was referred for abdominal pain. The angio-CT scan confirmed the previous EVAS procedure and showed a type Is2 endoleak below the right renal artery resulting in a 2.5 cm aortic blister with contrast medium filling the space between the aortic wall and the endobags. The patient was considered unfit for conventional open surgery and an endovascular approach with …

medicine.medical_specialtyAbdominal painEndoleakmedicine.medical_treatmentCase ReportEndovascular aneurysm repairSettore MED/22 - Chirurgia Vascolare03 medical and health sciences0302 clinical medicineAneurysmMedicineLocal anesthesiaEmbolizationRight Renal Arterybusiness.industryCoil embolizationPerioperativemedicine.diseaseAneurysmSurgeryContrast medium030220 oncology & carcinogenesis030211 gastroenterology & hepatologySurgerymedicine.symptombusinessNellix
researchProduct

Predictive value of IL-6 and IL-10 serum levels in anastomotic leakage in elderly patients undergoing surgery for colorectal cancer

2009

Methods The study group is yet represented by 33 patients: 17 males and 16 females (median age 76, range 70–89). The location of cancer was respectively: 5 (15, 15%) in the rectum, 15 (45, 45%) in the left colon, 11 (33, 33%) in the right colon, 1 (3, 3%) in the transverse colon, 1 (3, 3%) synchronous in the caecum and the sigmoid colon. The associated diseases observed were: chronic obstructive pulmonary disease, hypertension, diabetes mellitus, ischemic heart disease arterial vasculopathy.

medicine.medical_specialtyAnastomotic leakage IL-6 IL-10 elderly patients surgerybiologyColorectal cancerbusiness.industryTransverse colonCancerRectumSigmoid colonDiseaselcsh:Geriatricsmedicine.diseaseGastroenterologydigestive system diseaseslcsh:RC952-954.6Settore MED/18 - Chirurgia Generalemedicine.anatomical_structureDiabetes mellitusInternal medicineMeeting Abstractmedicinebiology.proteinGeriatrics and GerontologyInterleukin 6business
researchProduct

Neumoencefalo a tensión tras herida en cuero cabelludo en portadora de válvula de derivación ventrículo-peritoneal: caso clínico y revisión de la lit…

2009

El neumoencéfalo se produce la mayoría de las veces por una solución de continuidad en el cráneo e incluso en las meninges. En ocasiones, ciertos factores pueden hacer que éste adopte las características de un neumoencéfalo a tensión provocando una clínica neurológica severa. Presentamos el caso de una paciente de 66 años portadora de una doble válvula de derivación ventrículo-peritoneal que acude a Urgencias con un cuadro de hipertensión intracraneal y que tras la exploración física y la tomografía computarizada se detecta una herida en cuero cabelludo y un neumoencéfalo a tensión. Este defecto en piel se hallaba justo en la zona del borde de una plastia craneal colocada tras la resección …

medicine.medical_specialtyCerebrospinal fluid leakbusiness.industrymedicine.medical_treatmentNeumoencéfaloHipertensión intracranealIntracranial hypertension syndromemedicine.diseaseVálvula ventrículoperitonealCranioplastySurgeryMeningiomaSkullHerida en scalpmedicine.anatomical_structurePneumocephalusSurgical removalmedicineSurgeryScalp woundNeurology (clinical)businessNeurocirugía
researchProduct

A systematic review and meta-analysis comparing surgical and oncological outcomes of upper rectal, rectosigmoid and sigmoid tumours.

2021

Abstract Aim Management paradigms for tumours from the sigmoid colon to the lower rectum vary significantly. The upper rectum (UR) represents the transition point both anatomically and in treatment protocols. Above the UR is clearly defined and managed as colon cancer and below is managed as rectal cancer. This study compares outcomes between sigmoid, rectosigmoid and UR tumours to establish if differences exist in operative and oncological outcomes. Methods Electronic databases were searched for published studies with comparative data on peri-operative and oncological outcome for upper rectal and sigmoid/rectosigmoid (SRS) tumours treated without neoadjuvant radiation. The search adhered t…

medicine.medical_specialtyColorectal cancermedicine.medical_treatmentHealth StatusRectumAnastomotic LeakAnastomosis03 medical and health sciences0302 clinical medicinemedicineHumansNeoplasm MetastasisIntraoperative ComplicationsLymph nodeNeoplasm Stagingbusiness.industryRectal NeoplasmsRectumSigmoid colonCancerGeneral Medicinemedicine.diseaseRadiation therapySurvival RateSigmoid Neoplasmsmedicine.anatomical_structureTreatment OutcomeOncology030220 oncology & carcinogenesisMeta-analysisLymphatic Metastasis030211 gastroenterology & hepatologySurgeryRadiologyNeoplasm GradingNeoplasm Recurrence LocalbusinessEuropean journal of surgical oncology : the journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology
researchProduct

Trans-limb embolization for treatment of Type 2 endoleak post EVAR: Case report

2021

Introduction Type 2 endoleaks (T2EL) occur after 10%–25% of endovascular abdominal aortic aneurysm repairs and increase the risk factor of endograft repair failure and rupture. Herein we report a case of endovascular treatment of T2EL where we performed a trans-limb embolization. Presentation of case A 63-years-old male previously treated for AAA with endovascular aortic aneurysms repair (EVAR), showed an angio-CT scan followup with a type 2 endoleak fed from inferior mesenteric artery (AMI) with growth of AAA greater of 1 cm than preoperative CT-scan and increase of chronic lumbar pain. Due to high risk of rupture was performed a trans-limb embolization with complete sealing. The 6 months …

medicine.medical_specialtyEndoleak type 2business.industrymedicine.medical_treatmentCoil embolizationmedicine.diseaseSize increaseInferior mesenteric arteryAneurysmSettore MED/22 - Chirurgia VascolareAbdominal aortic aneurysmSurgeryAneurysm ruptureLumbarAneurysmmedicine.arteryCase reportcardiovascular systemMedicineSurgerycardiovascular diseasesEmbolizationRisk factorbusiness
researchProduct

Current role of the chimney technique in the treatment of complex abdominal aortic pathologies: A position paper from the PERICLES Registry investiga…

2020

Historically, chimney/snorkel endovascular aortic repair (Ch-EVAR) emerged as a rescue technique to revascularize and/or preserve inadvertently covered critical branch vessels during infrarenal aortic endografting. Next, in its evolutionary path, Ch-EVAR offered a viable treatment option for complex aortic repair, and particularly in situations where fenestrated/ branched EVAR was not a therapeutic option due to the lack of availability and/or anatomical constraints. In this context, this technique offered distinct advantages such as off-the-shelf availability, straightforward implantation techniques, and lower resource use-intensity enabling performance by a large number of operators manag…

medicine.medical_specialtyEndoleakChimney technique pararenal aneurysms endovascular aortic repairRisk Assessmentpararenal aneurysmsBlood Vessel Prosthesis ImplantationRisk FactorsHumansMedicineRadiology Nuclear Medicine and imagingChimneyRegistriesChimney technique; pararenal aneurysms; endovascular aortic repairendovascular aortic repairEvidence-Based Medicinebusiness.industryEndovascular ProceduresGeneral MedicineBlood Vessel ProsthesisTreatment OutcomeChimney techniquePosition paperStentsSurgeryRadiologyCurrent (fluid)Cardiology and Cardiovascular MedicinebusinessAortic Aneurysm Abdominal
researchProduct