Control and prevention measures for legionellosis in hospitals: A cross-sectional survey in Italy

2018

Abstract Risk assessment, environmental monitoring, and the disinfection of water systems are the key elements in preventing legionellosis risk. The Italian Study Group of Hospital Hygiene of the Italian Society of Hygiene, Preventive Medicine, and Public Health and the Italian Multidisciplinary Society for the Prevention of Health Care-Associated Infections carried out a national cross-sectional survey to investigate the measures taken to prevent and control legionellosis in Italian hospitals. A multiple-choice questionnaire was developed, comprising 71 questions regarding hospital location, general characteristics, clinical and environmental surveillance, and control and preventive measur…

0301 basic medicinemedicine.medical_specialtyCross-sectional studyLegionellamedia_common.quotation_subject030106 microbiologyControl measuresBiochemistryControl measures; Hospital; Legionellosis; National survey; Prevention; Biochemistry; 2300Legionella pneumophila03 medical and health sciencesHospital0302 clinical medicineControl measures; Hospital; Legionellosis; National survey; Prevention; Cross Infection; Cross-Sectional Studies; Disinfection; Humans; Infection Control; Italy; Legionella pneumophila; Legionellosis; Surveys and Questionnaires; Water Microbiology; Water SupplyHygieneWater SupplyLegionellosiSurveys and Questionnairesmedicinecontrol measures; hospital; legionellosis; national survey; preventionControl measures Hospital Legionellosis National survey Prevention Biochemistry 2300Humans030212 general & internal medicineSeroconversionGeneral Environmental SciencePreventive healthcaremedia_commonResponse rate (survey)National surveyCross InfectionInfection ControlLegionellosisbiology2300business.industryPublic healthPreventionControl measurebiology.organism_classificationDisinfectionCross-Sectional StudiesItalyEmergency medicinebusinessRisk assessmentWater Microbiology
researchProduct

[Legionella spp. contamination in indoor air: preliminary results of an Italian multicenter study].

2014

Obiettivo. Rilevare la presenza di Legionella spp. nell’aria attraverso un protocollo standardizzato, a fianco dei tradizionali metodi impiegati per la rete idrica. Disegno. In dieci strutture sanitarie è stato selezionato un bagno, la cui acqua presentava una contaminazione da Legionella >1.000 unità formanti colonie (ufc)/litro. La contaminazione dell’aria è stata valutata tramite campionamento attivo (Surface Air System, SAS) e passivo, impiegando piastre di sedimentazione per la valutazione dell’Indice Microbico Aria (Index of Microbial Air, IMA). I campionamenti sono stati effettuati per 8 ore consecutive, a circa 1 m dal pavimento e a 50 cm dal rubinetto. Con il campionamento attivo, …

Air MicrobiologyLegionellaLegionella indoor ariaindoor airSettore MED/42 - Igiene Generale E ApplicataWaste Disposal FluidcontaminationAir PollutionHumansIndoorToilet FacilitiesCross InfectionLegionellosislegionella spp; contamination; indoor airLegionella aria acqua SAS IMAWaste Disposalbacterial infections and mycosesariaHospitalsrespiratory tract diseasesBacterial Typing TechniquesItalyAir Pollution IndoorBacterial Typing Techniques; Cross Infection; Environmental Monitoring; Hospitals; Humans; Italy; Legionella; Legionellosis; Toilet Facilities; Waste Disposal Fluid; Water Microbiology; Air Microbiology; Air Pollution Indoorlegionella sppbacteriaFluidWater MicrobiologyEnvironmental MonitoringEpidemiologia e prevenzione
researchProduct

Genetic Characterization of Legionella pneumophila Isolated from a Common Watershed in Comunidad Valenciana, Spain

2013

Legionella pneumophila infects humans to produce legionellosis and Pontiac fever only from environmental sources. In order to establish control measures and study the sources of outbreaks it is essential to know extent and distribution of strain variants of this bacterium in the environment. Sporadic and outbreak-related cases of legionellosis have been historically frequent in the Comunidad Valenciana region (CV, Spain), with a high prevalence in its Southeastern-most part (BV). Environmental investigations for the detection of Legionella pneumophila are performed in this area routinely. We present a population genetics study of 87 L. pneumophila strains isolated in 13 different localities…

Evolutionary GeneticsBacterial DiseasesPopulation geneticslcsh:MedicineLocus (genetics)Legionella pneumophilaMicrobiologyMicrobial EcologyLegionella pneumophilaIntergenic regionGenetic variationmedicineNatural SelectionGeneticsGram Negativelcsh:ScienceBiologyMicrobial PathogensGeneticsRecombination GeneticGenetic diversityEvolutionary BiologyMultidisciplinaryLegionellosisbiologyEcologyEcologyPontiac feverlcsh:ROutbreakGenetic Variationbiology.organism_classificationmedicine.diseaseBacterial PathogensInfectious DiseasesSpainMicrobial EvolutionGenetic PolymorphismMedicinelcsh:QWater MicrobiologySequence AnalysisPopulation GeneticsResearch ArticlePLoS ONE
researchProduct

Występowanie pałeczek Legionella sp. w instalacjach wodnych obiektów użyteczności publicznej w województwie opolskim w latach 2010-2011

2012

CEL PRACY. Ocena kolonizacji sieci wodnej szpitali i obiektów użyteczności publicznej bakteriami Legionella sp. w województwie opolskim, w latach 2010 – 2011. MATERIAŁ I METODY. Ocenę przeprowadzono na podstawie wykonanych w latach 2010 – 2011 badań ciepłej wody w kierunku Legionella oraz meldunków sprawozdawczych MZ-56 i MZ-57 dotyczących zachorowań na choroby zakaźne. WYNIKI. Przeprowadzone badania ciepłej wody wykazały, że znaczący odsetek budynków użyteczności publicznej w woj. opolskim posiada skolonizowaną instalację wodną bakteriami Legionella sp. W grupie zbadanych obiektów, największy procent obiektów z kolonizacją sieci wodnej bakteriami Legionella sp. stanowią szpitale (2010 - 63…

Legionella sp. bacillipałeczki Legionella sp.szpitalewater systemslegionellosislegionelozawaterwodahospitalsinstalacje wodnecolonizationkolonizacjabiofilmPrzegląd Epidemiologiczny
researchProduct

Legionellosis Outbreak Associated with Asphalt Paving Machine, Spain, 2009

2010

From 1999 through 2005 in Alcoi, Spain, incidence of legionellosis was continually high. Over the next 4 years, incidence was lower, but an increase in July 2009 led health authorities to declare an epidemic outbreak. A molecular epidemiology investigation showed that the allelic profiles for all Legionella pneumophila samples from the 2009 outbreak patients were the same, thus pointing to a common genetic origin for their infections, and that they were identical to that of the organism that had caused the previous outbreaks. Spatial-temporal and sequence-based typing analyses indicated a milling machine used in street asphalt repaving and its water tank as the most likely sources. As oppos…

MaleMicrobiology (medical)Epidemiologylcsh:MedicineBiologymilling machineDisease OutbreaksLegionella pneumophilalcsh:Infectious and parasitic diseasesEnvironmental healthmedicineHumanslcsh:RC109-216Sequence-based TypingbacteriaAllelesPhylogenyAgedAged 80 and overMolecular EpidemiologyoutbreaklegionellosisMolecular epidemiologyResearchIncidence (epidemiology)lcsh:ROutbreakMiddle Agedmedicine.diseaseVirologyHydrocarbonsnatural spring waterInfectious DiseasesStreet cleaningSpainEpidemic outbreaksequence-based typingFemaleLegionnaires' diseaseLegionnaires' DiseaseWater MicrobiologyLegionnaires’ diseaseEmerging Infectious Diseases
researchProduct

Enzyme-linked immunoassay for detection of PCR-amplified DNA of legionellae in bronchoalveolar fluid.

1995

A nonradioactive method is described that detects 10 to 100 legionellae in 1 ml of bronchoalveolar lavage fluid. DNA is purified by a proteinase K-phenol protocol or with a commercial DNA preparation kit and amplified by PCR with amplimers specific for the 16S rRNA gene of Legionella pneumophila. The upstream primer is 5' biotinylated. The amplification product is immobilized on streptavidin-coated microtiter plates. Because of the high binding capacity, no removal of nonincorporated biotin from the PCR product is required. After alkaline denaturation, the single-stranded PCR product is hybridized with a 5' digoxigenin-labeled probing oligomer. The amplification product is then detected by …

Microbiology (medical)DNA BacterialLegionellaMolecular Sequence DataLegionella PneumoniaLegionellaLegionella pneumophilaPolymerase Chain ReactionSensitivity and SpecificityMicrobiologylaw.inventionLegionella pneumophilaImmunoenzyme TechniquesSpecies SpecificitylawRNA Ribosomal 16SSequence Homology Nucleic AcidmedicineHumansPolymerase chain reactionLegionellosisbiologymedicine.diagnostic_testBase SequenceHybridization probebiology.organism_classification16S ribosomal RNAmedicine.diseaseMolecular biologyrespiratory tract diseasesRNA BacterialBronchoalveolar lavageEvaluation Studies as TopicGenes BacterialLegionnaires' diseaseLegionnaires' DiseaseDNA ProbesBronchoalveolar Lavage FluidResearch Article