Visual function comparison of 2 aspheric multifocal intraocular lenses
2011
To compare visual function after bilateral implantation of the multifocal Lentis Mplus LS-312 with a nonrotational symmetrical design (copolymer aspheric) or the Acrysof Restor SN6AD1 +3.0 D (hybrid aspheric) intraocular lens (IOL).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Comparative case series.Six months postoperatively, corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), the defocus curve, and photopic and mesopic contrast sensitivity with and without glare were measured.The mean CDVA was 0.02 ± 0.06 (SD) with the copolymer aspheric IOL and -0.06 ± 0.05 logMAR with the hybrid aspheric IOL (P=.07) and the mean DCNVA, 0.10 ± 0.06 and -0.0…
Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
2012
PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients ha…
Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens
2007
To determine whether pupil size is correlated with visual acuity and contrast sensitivity at all distances in eyes with an apodized diffractive intraocular lens (IOL).Private Clinic, Oviedo, Spain.Six months after surgery, the best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m2) and mesopic (5 cd/m2) conditions were measured in 670 eyes of 335 consecutive patients who had implantation of the AcrySof ReSTOR Natural IOL (SN60D3, Alcon). Pupil diameters in distance vision were measured using a pupillometer.The logMAR best corrected distance acuity was significantly better with …
Bilateral implantation of the Acri.LISA bifocal intraocular lens in myopic eyes.
2009
Purpose To asses visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL) (Carl Zeiss Meditec) in patients with high and low–moderate myopia. Methods A total of 304 eyes of 152 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low–moderate myopia (IOL power from 15 to 20.5 D) and high myopia (IOL power from 0 to 14.5 D). Monocular and binocular best-corrected distance visual acuity (BCVA) and best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (BCIVA), and distance contrast sensitivity (OS) under photopic (85 cd/m2) and mesopic (5 cd/m2) conditio…
Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens
2013
Purpose: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof ReSTOR (SN6AD3 model) intraocular lens (IOL) Methods: Sixty eyes of 30 consecutive patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patients sample was divided into myopic [n=15, mean spherical equivalent (SE) -6.87± 2.03 diopters (D)] and hyperopic (n=15, mean SE +4.52±1.14 D) groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respec…
Series of fibrinous inflammation after implantation of capsular tension rings
2014
Purpose To analyze the cause of fibrinous inflammation in eyes with capsular tension rings (CTRs) after cataract surgery. Setting Department of Ophthalmology, University Medical Center, Johannes Gutenberg-University Mainz, Mainz, Germany. Design Retrospective case series. Methods High-performance liquid chromatography was implemented to eliminate impurities. One CTR was explanted for microbiologic examination. The pH values of the CTR and the storage solution were analyzed, Seldi and Maldi tests were performed, as well as toxicity tests with immortal cell lines. Material batches were analyzed. The organic carbon content of CTRs, detergents, and storage solutions was checked. The presence of…
Visual and optical performance with the ReZoom multifocal intraocular lens
2011
Purpose This study evaluated visual acuity, contrast sensitivity, and wavefront aberrations after refractive multifocal intraocular lens (IOL) implantation. Methods A prospective study comprising 174 eyes of 87 patients who had bilateral implantation of a multifocal IOL was carried out. A control group of 100 eyes of 50 age-matched patients with a monofocal IOL was used for comparison. Uncorrected and corrected distance and near visual acuity, contrast sensitivity (CS), and wavefront analysis (Hartmann-Shack) was performed 6 months after surgery. Contrast sensitivity was tested for distance and near under mesopic (2 cd/m2) and photopic conditions (90 cd/m2). Results Distance photopic CS was…
Prospective visual evaluation of apodized diffractive intraocular lenses
2006
To evaluate distance, intermediate, and near visual performance in patients who had multifocal apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, distance contrast sensitivity under photopic and mesopic conditions, and patient satisfaction were measured in 325 patients and 335 patients who had bilateral implantation of the model SA60D3 IOL (AcrySof ReSTOR, Alcon) and model SN60D3 IOL (AcrySof Natural ReSTOR), respectively.At the 6-month postoperative visit, binocular best corrected distance acuity with the ReSTOR IO…
Refractive lens exchange with Acri.LISA bifocal intraocular lens implantation.
2011
PURPOSE To assess efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had bilateral implantation of an Acri.LISA 366D diffractive bifocal intraocular lens (IOL). METHODS Sixty-six eyes of 33 consecutive patients were examined after RLE who had bilateral implantation of an Acri.LISA bifocal 366D IOL. Eyes were divided into myopic and hyperopic groups. Monocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.73 for myopic and 0.85 for hype…
Prospective study of the Acri.LISA bifocal intraocular lens
2007
To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospective study. Monocular and binocular best corrected distance visual acuity and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 3-month postoperative visit, the mean binocular best corrected distance acuity was 0.048 +/- 0.111 log…